Proposal Plans
Original PDF page 8, section 1. The text section number identifies this passage in the reader.
C:\Users\User\Archicology Pty Ltd\Archicology - Projects
\Archicology Projects\20531 Tewantin 40 x 40\20531 SD model
\20531 SD MODEL scheme B 010221.pln
SD ISSUE
DRAFT A by NF on 27/07/20 for Review
ISSUE 1 by NF on 31/07/20 for Consultation
ISSUE 2 by NF on 14/10/20 for SCHEME B
ISSUE 3 by NF on 27/11/20 for Consultants
ISSUE 4 by NF on 18/12/20 for Approval
20° fall
ISSUE 5 by NF on 21/01/21 for DA Submission
20° fall 20° fall
20° fall
5,510
8,510
190
D.P D.P
D.P
D.P
D.P
D.P
2,807
Balcony Balcony Balcony Balcony Balcony
AC Unit
AC Unit
AC Unit
AC Unit
AC Unit
22.20 m2 19.80 m2 19.80 m2 19.80 m2 22.20 m2
HWS HWS HWS HWS HWS
CRIMSAFE TO WINDOWS
CRIMSAFE TO WINDOWS
Discontinuous CTR + 50
Discontinuous CTR + 50
Living Bed 2 Bed 2 Living Bed 2 Living Living Bed 2 Bed 2 Living
window hood below
Robe Robe Robe
Robe Robe
Dining D D Dining
Ldry
Ldry
Ldry
WM
Dining Dining Dining WM
WM
WM
WM
CRIMSAFE TO WINDOWS
Bath Ldry Ldry Bath
Bath Bath Bath
DW DW
3,095
REF
REF
D D D
Kitchen DW DW DW
Kitchen
REF REF REF
Ens Ens
Ens Kitchen Ens Kitchen Kitchen Ens
P
P
REF
CUP
CUP
D.P D.P 2,495
ELECT
ELECT
Robe Robe
P P P
81.55 m2 81.84 m2 81.84 m2 81.84 m2 81.55 m2
Discontinuous CTR + 50
Tread width:
Riser:
Total rise:
1.450
0.181
0.250
ELECT ELECT ELECT
Discontinuous CTR + 50
Linen Linen Linen
Tread width:
Total rise:
Entry Bed 1 Bed 1 Entry Bed 1 Entry Entry Bed 1 Bed 1 Entry
30 30
Riser:
0.250
0.181
1.450
31 31
32
Robe Desk Robe Desk Desk Robe 32
Fire Stairs Fire Stairs
RL 11.64 RL 11.64
F. H. R.
D.P
F. H. R.
10.20 m2 13.20 m2 13.20 m2 13.20 m2 10.20 m2
Clothes Line Clothes Line Clothes Line Clothes Line Clothes Line
75.11 m2 UNIT 10 PBX PBX
UNIT 9 PBX
UNIT 8 UNIT 7 PBX PBX
UNIT 6
Shotton Lift
Lift
Level 2 Unit Areas
1
1:100
ARCHICOLOGY P/L
architecture
about people
ph 5446 3113
Po Box 579 Coolum Beach 4573
The builder shall check and verify all dimensions and
verify any errors and omissions to the architect. Do not
scale off drawings. Drawings shall not be issued for
construction purposes until issued by the Architect for
construction. In the first instance contact :
Mr Adrian Just on 0412 117772
Client Name
Project Name
Tewantin 40 x 40
SCHEME B : 2 LEVELS : 19 UNITS
30 & 32 Doonella St, Tewantin QLD, 4566
Drawing Title:
Areas - Level 2
Scale: As shown Date: 2020
Status: SD Checked By: ACJ
Project No: Drawing No.:
20531 SD09
Plot Date: 1/02/2021