Original source · versioned page text
Proposal Plans
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
C:\Users\User\Archicology Pty Ltd\Archicology - Projects
\Archicology Projects\20531 Tewantin 40 x 40\20531 SD model
C
\20531 SD MODEL scheme B 010221.pln
D
N
20° fall
SD ISSUE
DRAFT A by NF on 27/07/20 for Review
20° fall 20° fall
ISSUE 1 by NF on 31/07/20 for Consultation
ISSUE 2 by NF on 14/10/20 for SCHEME B
20° fall
ISSUE 3 by NF on 27/11/20 for Consultants
5,510
ISSUE 4 by NF on 18/12/20 for Approval
ISSUE 5 by NF on 21/01/21 for DA Submission
8,510
190
D.P D.P
D.P
D.P
D.P
D.P
2,807
Balcony Balcony Balcony Balcony Balcony
AC Unit
AC Unit
AC Unit
AC Unit
AC Unit
HWS HWS HWS HWS HWS
A A
CRIMSAFE TO WINDOWS
CRIMSAFE TO WINDOWS
Discontinuous CTR + 50
Discontinuous CTR + 50
Living Bed 2 Bed 2 Living Bed 2 Living Living Bed 2 Bed 2 Living
window hood below
Robe Robe Robe
Robe Robe
Dining D D Dining
Ldry
Ldry
Ldry
WM
Dining Dining Dining WM
WM
WM
WM
CRIMSAFE TO WINDOWS
Bath Ldry Ldry Bath
Bath Bath Bath
DW DW
3,095
REF
REF
D D D
Kitchen DW DW DW
Kitchen
REF REF REF
Ens Ens
Ens Kitchen Ens Kitchen Kitchen Ens
P
P
REF
CUP
CUP
D.P D.P 2,495
ELECT
ELECT
Robe Robe
P P P
Discontinuous CTR + 50
1.450
0.181
0.250
Tread width:
Riser:
Total rise:
ELECT ELECT ELECT
Discontinuous CTR + 50
Linen Linen Linen
Tread width:
Total rise:
Entry Bed 1 Bed 1 Entry Bed 1 Entry Entry Bed 1 Bed 1 Entry
30 30
Riser:
0.250
0.181
1.450
31 31
32
Robe Desk Robe Desk Desk Robe 32
Fire Stairs Fire Stairs
RL 11.64 RL 11.64
F. H. R.
D.P
F. H. R.
Clothes Line Clothes Line Clothes Line Clothes Line Clothes Line
UNIT 10 PBX PBX
UNIT 9 PBX
UNIT 8 UNIT 7 PBX PBX
UNIT 6
Shotton Lift
Lift
open pergola open pergola
open pergola
dpdp
dpdp dp dp
dp
dp dp
dp
1,995
12° fall
12.5° fall
10° fall 10° fall
B 12° fall 12° fall B
12.5° fall 12.5° fall dp
dp
dp
12.5° fall
open pergola
12° fall
ARCHICOLOGY P/L
architecture
open pergola
about people
ph 5446 3113
1,902 dp
dp
dp Po Box 579 Coolum Beach 4573
1,000
dp
dp
dp
dp
3,500 The builder shall check and verify all dimensions and
verify any errors and omissions to the architect. Do not
scale off drawings. Drawings shall not be issued for
construction purposes until issued by the Architect for
20° fall
construction. In the first instance contact :
20° fall 20° fall
Mr Adrian Just on 0412 117772
6,000
6,000
6,000
20° fall
Client Name
Project Name
approx. sewer line
Tewantin 40 x 40
SCHEME B : 2 LEVELS : 19 UNITS
30 & 32 Doonella St, Tewantin QLD, 4566
Level 2 Plan
C
D
Drawing Title:
1
1:100 Level 2 Plan
Scale: As shown Date: 2020
Status: SD Checked By: ACJ
Project No: Drawing No.:
20531 SD04
Plot Date: 1/02/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Proposal Plans.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.