App B - Effluent Information
Appendix B Effluent Information Application for a Development Permit – Material Change of Use for Short-Term Accommodation in a 46.5m² dwelling. 122 Musa Vale Road, Cooroy 4563 QLD Lot 304 on SP118015 James Austin & Jody Austin 22nd April 2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (App B - Effluent Information.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 15 pages
Page 2
Building & Plumbing Services
Direct Telephone | 5329 6480
Email | [email protected]
Application Number PL23/0174
25 June 2024
Dream Modular Homes
Invalid Address
Dear Sir/Madam
Compliance Certificate For PL23/0174
Plumbing and Drainage Regulation 2019
1. PROPERTY DETAILS
Application No: PL23/0174
Street address: 122 Musa Vale Rd COOROY QLD 4563
Real property description: Lot 304 SP 118015
2. APPLICATION DETAILS
Secondary Dwelling - 8 Fixtures & AES
3. INSPECTION RESULTS
Council's decision is to issue a Compliance Certificate for the regulated work (that is
plumbing and drainage work and/or on-site sewerage work) in relation to the scope of work
mentioned above.
The work was inspected on the following dates at the respective stages. Where a stage of
work was not assessed by a Council Plumbing Inspector; a Form 3 - Covered Work
Declaration was obtained from the responsible person.
STAGE OF WORK INSPECTION DATE
Drainage 07/11/2023
Land Application Area 20/10/2023
Final Inspection 12/01/2024
If you have any questions about the content of this Certificate, please contact Council’s
Plumbing Services as detailed above.
Yours faithfully
Owen Hewitt
PLUMBING INSPECTOR
Document Set ID: 23075699
Version: 1, Version Date: 25/06/2024
Page 3
cc
JL Austin & Mr JN Austin
130 Kadumba St
YERONGA QLD 4104
WR GARLAND
37 THE DECKS
WURTULLA
QLD 4575
Document Set ID: 23075699
Version: 1, Version Date: 25/06/2024
Page 4
GENERAL NOTES: This form is to be used for the purposes of section 81 of the Plumbing and
Drainage Regulation 2019 (PDR).
1. Description of Street address (include number, street, suburb/locality and
land postcode)
122 Musa Vale Rd COOROY QLD 4563
Lot and plan:
Lot 304 SP 118015
Local
Shop/tenancy government
number Storey/level area
Noosa
(if applicable) (if applicable)
2. Permit details Permit number Date issued
PL23/0174 13 July 2023
3. Declaration/s
1. This certificate applies to all of the work authorised to be carried
out under the permit
Local government or
the public entity may in or
certain circumstances
accept verification from 2. This certificate applies to part of the work authorised under a
the responsible person permit.
that certain work not
inspected by local
government complies If two (2) applies, provide a description of work covered by the certificate.
with the relevant
standards.
4. Certification This form certifies that the relevant local government or the public entity
has decided to issue a Final inspection certificate for the work described
above.
The work is compliant, operational and fit for use.
Date the inspection was carried
12 January 2024
out
Certificate number (if applicable) Not Applicable
Issued by
Noosa Council
(insert local government name/public entity)
Date issued 25 June 2024
Document Set ID: 23075699
Version: 1, Version Date: 25/06/2024
Page 5
iDesign
Sunshine Coast Office
PO Box 6218
Mooloolah Valley Q4553
wastewater solutions P. 0407 887 321
Biowater Designs Pty Ltd QBCC Lic 1049265 E. [email protected]
PROPOSED DETACHED STUDIO
SITE & SOIL EVALUATION
Lot 304 SP 118015
Address: 122 Musa Vale Road, Cooroy
Area: 415650.84m2
Date: 21st April 2023
Reference No: NC/2023/AES/122MusaV
INDEX:
1.0 Introduction:
2.0 Site Description: p2
IMPORTANT DIRECTION
3.0 Soil Investigation: Do not install from this design until it is
Stamped and Approved by the Local Authority.
3.3 Soil Classification Council may make changes to this design as part
4.0 Recommendations: p3 of the approval process. Only install from Stamped
Approved Plans and refer to the Approval Permit for
5.0 Design Calculation possible changes.
5.1 AES Infiltration Bed Design: p4
AES Calculator p5
7.0 Design Drawings p6
reuse
7.1 Design Drawings p7
Borelogs p8 recycle
Site Classification p9
retrieve
Articulation Joint Illustration p10
Inspection Port p11 C Copyright Lance Picton 2023 design & content. 1/11
Page 6
1.0 Introduction:
Biowater Designs Pty Ltd, in accordance with AS/NZS1547-2012 ( Domestic Wastewater Management ) and the
Queensland Plumbing & Wastewater code (QPW) 2019 Version 1, was commissioned to undertake a Site & Soil Evaluation
in the Noosa Council at 122 Musa Vale Road, Cooroy.
The results form the basis of our recommendations for on site wastewater disposal.
Our site investigation and field work was performed on Tuesday 11th April 2023 after a period of dry weather.
The investigation was undertaken to determine the soil profile and Long Term Acceptance Rate (LTAR) of the site in order
to accommodate a proposed new 1 bedroom detached studio. No laundry facilities will be provided in the studio.
NOTE: This evaluation was undertaken at the owner’s request after considerable discussion regarding environmental issues
of this site and preferred design of the Land Application Area.
2.0 Site Description:
2.1 Existing Buildings: Main dwelling and sheds. The existing dwelling does not form part of this assessment.
2.2 Site Factors:
The site is a large rural allotment the area is 415650.84m2.
The proposed Land Application Area is moderately sloping (5-15%).
The proposed Land Application Area has very good exposure to sun and wind.
Erosion, mass movement or land slip was not observed on this site. There are no visible rock outcrops on this site.
The proposed Land Application Area has approximately 100% grass cover.
There are no creeks, dams, bores or waterways on the site or adjoining sites within the setback requirements under the
Queensland Plumbing and Wastewater Code for Advanced Secondary effluent.
No groundwater was encountered to a depth of 2000mm.
There is no evidence of fill in the proposed Land Application Area.
Rain water will not transverse this site from adjoining properties during heavy rains.
Concentrated run-off from this property will not transverse adjoining properties during heavy rains.
Soils were dry and there is no evidence of soil surface cracking in the LAA. No evidence of compaction or seepage areas.
Salinity is not evident.
3.0 Soil Investigation:
3.1 Drainage Pattern: Linear Planar
3.2 Method:
Soil testing was conducted by Ground Drill Pty Ltd on 11th April 2023 to a depth of 2000mm within the proposed
Land Application Area. See borelogs page 8.
The soils were visual one textually classified in accordance with Table E1 AS/NZS 1547:2012.
Strongly structured Light Clays. Category 5 adopted.
Smooth plastic ball that can be rolled into a rod; slight resistance to shearing between
thumb and forefinger; forms a ribbon 50-75 mm long. Category 5 adopted.
The Site Classification has been completed by Ground Drill Pty Ltd and indicates class “P” site. See page 9.
Articulation Joints are therefore required and must be designed by a suitable qualified person.
C Copyright Lance Picton 2023 design & content. 2/11
Page 7
3.3 Soil Classification
Soil Classification - Adopted
Borehole Nos 1&2
Soil Category Adopted 5
Indicative Drainage Poorly Drained
Structure Strongly
Texture Light Clay
Indicative Permeability P (m/d) as Ksat* 0.12 - 0.5
Recommended DLR (AS/NZS 1547 / 2012) 10
4.0 Recommendations:
4.1 Treatment Facility:
The on-site treatment facility to service the new studio is to be an Advanced Enviro-Septic System (AES). This
system has a Chief Executive Approval # 15/2019 for Advanced Secondary Effluent. The Person Equivalent (PE) for
this system is to be no less than 3.
A new min 3000L all waste septic tank is to be installed to service the detached dwelling.
All wastewater from the detached dwelling is to be directed to the septic tank then to the AES bed.
The Land Application Area is to be an Advanced Enviro-Septic Infiltration Bed of 36m2.
All work is to be done by appropriately trained and licenced plumbers/installers.
5.0 Design Calculation - Detached Dwelling
The serviceable life of the Land Application Area will be compromised if the design flow is exceeded. Any
proposed changes to the position of the Land Application Area, System Type or House Design will require a
reassessment of this site. For our calculations we have assessed the design flow as follows:
Design Calculation
DLR (mm/d) (secondary quality effluent) 10
Hydraulic load (lt/day/person) Tank Water / 2 bedrooms 120
Design Flow Q (lt/day) PE: 3 360
Design sizing calculation L = Q /(DLRxW)
= (360 / 10)
Disposal area A+B (square metres) AS/NZS1547:2012 36m2
Nominated Configuration (metres) AES System Design Calculations = 9m x 4m (L xW) 36m2
A new min 3000L septic tank is required. AES System PE 3
C Copyright Lance Picton 2023 design & content. 3/11
Page 8
5.1 AES Infiltration Bed Design. Advanced Enviro-Septic System
The AES Bed Design is to be a gravity fed, below ground system. See system design drawings page 6.
The total bed base required is 36m2 (9m x 4m). Bed is to be installed as shown on the site plan. See drawings page 6 for bed
profile. A minimum 4m setback is required to any tree.
The entire bed base it to be ripped 250mm parallel to the AES pipes and gypsum applied at 1kg per m2.
Coarse washed sand will be referred to as “system sand” and must meet the specifications of the system manufacturer.
System sand will need to be placed around AES pipework and for the infiltration area as shown on the attached drawings.
System pipe bed dimensions (Area A) are 6.6m x 1.35m and a total minimum sand depth of 750mm. 300mm of course washed
sand is to be spread to form a base and 2 rows of 2 lengths of AES pipes installed as per the attached drawings.
A further infiltration area (Area B) is to be constructed around and below the pipe bed as per the site drawings and a minimum of
150mm system sand to be spread over the entire infiltration area.
Pipes are to be covered by a minimum of 150mm of system sand. A further 150mm of site soil is to be mounded over the sand to
prevent surface water entering the bed. After all settlement the AES Bed is to have a minimum 150mm cover of site soil.
Beds are to be constructed in accordance with the AES Design and Installation Manual and all plumbing works in accordance with
the QPW code. All site work is to be carried out by a licenced plumber and all AES horizontal pipes layed with the aid of a laser
or dumpy level to ensure absolute compliance with the manufacturers installation guidelines. This is critical for correct operation.
Oxygen Demand Vents are to be installed as per the AES Design & Installation Manual. The high vent (100mm - on the studio)
must be a minimum of 3m higher than the AES low vent and provide unrestricted air flow through the entire system.
Two Inspection Ports are to be installed, one in the centre of the pipe bed and another at the furthest point from the influent to AES
Pipes. See Installation Instructions Appendix A - page 11.
Care must be exercised to prevent machinery access on the AES bed during and after construction.
6.0 Setback Regulations:
Secondary Advanced Secondary
Recommended Separations Distances - Surface Irrigation
Effluent Effluent
Dwellings & recreation areas 10m 10m
Water edge of swimming pools 6m 6m
Property boundaries, paths & walkways 2m uphill 2m uphill
4m down hill 4m down hill
Top of bank of permanent water course, creek, lake, waterway etc. 30m 10m
Bore or Dam for domestic or stock use 30m 10m
Vertical depth of seasonal water table 0.6m 0.3m
In ground potable water tank. Note some authorities require 15m 6m 6m
Sub-Surface Irrigation same as above except for;
Dwelling & recreation areas 4m 4m
NOTE: The local government authority may upon considering the public health and environmental risks
reduce or increase the distances in the above table.
Regards,
Lance Picton jp.
Site Classifier
QBCC Lic: 1049265
C Copyright Lance Picton 2023 design & content. 4/11
Page 9
5/11 [OCR of page images] ’ ADVANCED J ENVIRO-SEPTIC Advanced Enviro-septic Design Calculator v9.0 © “Always The First Option” AES The World Leader in Passive Solutions © Site Address 122 Musa Vale Rd Cooroy. State QLD Post Code Client Name Jody Austin Date of Site Visit Designers Biowater Design Pty Ltd Desaners Ph SO ieemadond “ence Meee Lic Plumber TBA Pramber Ph TBA Plumb Drainer Le TBA Council Area Noosa Designers AES 1 Date 21.04.2023, This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer. Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 >> This design is for an ADVANCED SECONDARY system Is this anew installation Y or N Y >> Minimun single vent size is 80mm or 2 x 50mm house vents Number of Bedrooms 1 >> This is not used in ANY Calculation. If not known use N/A or 0. Number of persons 3 >> A septic tank outlet filter is NOT RECOMMENDED Daily Design Flow Allowance Litre/Person/Day 120 Number of rows required to suit site constraints 2 >> The maximum length of a single AES pipe run is 30m or 10 PIPES Infiltration Soil Category from site/soil evaluation. CATEGORY 5 >> Catagory may require design considerations. Ref AS1547 Design Loading Rate based on site & soil evaluation DLR (mm/day) 10 >> Soil conditioning may be necessary. Ref AS1547 & Comments. Bore log depth below system Basal area 1.5m >> Min depth 1.5m. Check water table/restrictive layer Is this design a GRAVITY system with no outlet filter? Y or N Y >> GRAVITY. A House Vent & LOW VENT required on this system PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES COMMENTS :-" The outcome must be important to everyone. " - Ripping of receiving surface required in clay soil structures in Cat 4 In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe. - Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547 - Designers need to be familar with special requirements of Local Authorities. ie - Minimum falls from Septic tank outlets to Land application areas ete - Plumbers are reminded good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions AES System Calculator Outcomes AES dimensions Total System load - litres /day (Q). 360 Wd AES System Extension Area Min Length of AES pipe rows to treat loading 6.25 Im Length:(L) Number of FULL AES Pipe lengths per row 2 Iths Width:(W) ‘Sand Depth Total Capacity of AES System pipe in Litres 848 ltr, : 0.75m 0.15m ‘Area m2 8.9 m2 27.4 m*2 USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y) | | >>stope percentage must be 0% & infiltration footprint must be level for this design IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Y Enter Custom Width in metre 4 AES INFILTRATION FOOT PRINT AREA- L=Q/(DLR x W) Length Width Minimum AES foot print required The length & width of excavation required for this design is >> 9.00m x 400m = 36.0 m2 total AES pipes are best centered in the trench parallel to the site slope AES System Bill of Materials. Chankar Environmental Use Only AES-PIPE AES 3 metre Lengths required 4 Iths |AESC AES Couplings required 2 ea |AESO. AES Offset adaptors 4 ea a ADVANCED on ENVIRO-SEPTIC AESODV AES Oxygen demand vent 1 ea “Nature's Wastewater Solutions” AES-IPB AES 100mm Inspection point base 2 ea TD Kit 4 4 Hole Distribution Box Kit ea TD Kit 7 7 Hole Distribution Box Kit ea Digitally signed by Steve Dennis VS43-4 Sweet Air Filter VS43-4 ea DN: cn=Steve Dennis, o=Chankar AES DESO Double Offset Adaptors ea Enviromental, ou=Design Review, | email=steve@enviro- TOTAL SYSTEM SAND REQUIRED (Estimate Only) 13 m3 . septic.com.au, c=US Please email your AES Calculator (EXCEL FORMAT), Site Layout & AES Design to Date: 2023.04.22 17:30:13 +10'00' designreview @enviro-septic. comau— designreview @enviro-septic com au [> The AES Calculator is a design aid to allow checking of the AES components, configuration and is a guide only. Site and soil conditions referencing AS1547 are calculated and designed by a Qualified Wastewater Designer. |> Chankar Environmental accepts no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator. |> AES pipes can be cut to length on site. They are supplied in 3 meter lengths only. > AES ONLY supply AES components as detailed in the Bill of Materials. > SEPTIC Tank & other components including SAND will need to be sourced from other suppliers. Refer to our WEBSITE www.enviro-septic.com.au OR 07 5474 4055 AES-Design-V9.0-Calculator © Copy Right - Chankar Environmental Pty Ltd 20/1/2022 5/11
Page 10
7.0 Design Drawings This plan is site specific for 122 Musa Vale Road, Cooroy
9000mm
6000mm
Note:
Correct installation of connectors
in AES Manual page 9. Inlet
1350mm
level
Inspection Port Low Vent
AES pipe
pack sand
under 300mm
Ground level
Area A
4000mm
Infiltration Area (A) 9000 x 1350mm
Area B Entire bed base is to be ripped
Infiltration Area (B) 9000 x 2650mm 250mm parallel to AES Pipes
Gypsum applied at 1kg / m2.
Not to scale
Inspection Port
150mm
300mm 300mm
Imported sand (course washed)
150mm
Backfill with site soil min 150mm cover over sand 300mm Sand
and mound soil over bed to prevent water access.
AES Sand Coverage Minimums
IMPORTANT NOTES PLEASE READ.
troP noitcepsnI mm003 The installer MUST refer to the Advanced Enviro-Septic Design & Installation
Natural Ground Level 6 Manual provided. If you do not have a copy of this manual please contact Chankar
% slope Inspection Port Environmental and a copy will be emailed FREE.
150mm
150mm
Sections C, D, & E of the Design and Installation Manual are of particular relevance
when installing an Advanced Enviro-Septic System.
300mm
THIS IS NOT A SEPTIC TRENCH AND MUST BE INSTALLED AS PER THE
300mm AES DESIGN AND INSTALLATION MANUAL GUIDELINES.
Rip 250mm parallel to pipes. Gypsum 1kg / m2 Ensure you have the correct sand and all fittings to complete the installation if you
2650mm
are unsure of anything please contact Chankar Environmental (07) 54 744 055 or
1350mm
Scale 1:30 @ A3 Biowater Designs 07 54 947 620 or 0407 887 321.
C Lance Picton 2023 all rights reserved 6/11
Page 11
Proposed Cottage
SITE PLAN; This design is site specific for 122 Musa Vale Rd, Cooroy.
INSERT
Ac
INSERT
ce
ss
d a ry
Rd
d
ss R
oun
e rn b
East 4m
Acc e
139.4
Note:
Installer to select exact position and orientation of AES
system in vicinity of Bh1 & Bh2. and maximize setback
from large tree. Site cut
Proposed 1
bedroom studio
12
Min 3000L septic
.4m
tank (indicative position)
Notes: This report is based on information and BH#1
plans provided by the owner in addition to the
site information at the time of investigation. Large
It does not take into account any event, whether tree
by human intervention and/or by nature that occurs
after the date of the site investigation which affects 213.8 rn bounda BH#2
the results and findings contained within this report.
South
In the event that the site conditions change or
4m
e
the proposed development is altered in any way,
this office is to be notified to determine what if any
affect they may have on this design. Should a
re-design be required, further fees may apply.
ry
C Lance Picton 2023 all rights reserved 7/11
IMPORTANT DIRECTION Plan of:
Biowater Designs Pty Ltd Client: This plan to be read in conjunction with the All works must comply with AS/NZS1547:2012
Do not install from this design until it is Lot 304 SP 118015 James & Jody Austin attached report. and the Qld Plumbing and Wastewater code.
Stamped and Approved by the Local Authority. PO Box 6218
122 Musa Vale Rd Ph: 0405 602 750 The proposed Land Application Area must be
Council may make changes to this design as part Mooloolah Valley Q 4553
Cooroy installed and positioned as per this plan.
of the approval process. Only install from Stamped Ph: 07 54 947 620
Approved Plans and refer to the Approval Permit for
N Mob: 0407 887 321
Construction of any permanent structures
within the designated area is prohibited.
possible changes. Site Classifier: Date: SCALE:
Local Authority: Care must be taken to ensure no traffic or fill Site Area: 415650.84m2
Lance Picton jp 21st April 2023 Approx 1: 350 @ A3 Land Application Area: 36m2
Noosa Countil in the designated area during construction.
QBCC Lic 1049265
Page 12
Borelogs:
8/11
[OCR of page images]
Borelogs:
Percolation Borehole Logs
Perct Soil Description Perc2 Soil Description
0 TOPSOIL SANDY SILT, Brown, Fine to 0 TOPSOIL SANDY SILT, Brown, Fine
Medium Grained Sand, With CL-Ci Clay, to Medium Grained Sand, With CL-CI
Firm, Dry to Moist Clay, Firm, Dry to Moist
100 |SANDY CLAY (CI-CH), Orange Brown, 100 |SANDY CLAY (CI-CH), Orange
Fine Grained Sand, With Fine to Coarse Brown, Fine Grained Sand, With Fine
Grained Gravel, Trace Silt, Firm, Dry to Coarse Grained Gravel, Trace Silt,
Firm, Dry
200 200
300 300
400 400
500 500
600 600
700 700
800 800
900 900
1000 1000
1100 1100
1200 1200
1300 1300
1400 | SANDY CLAY (CI-CH), Mottled Grey 1400 |SANDY CLAY (CI-CH), Mottled Grey
Brown, Fine to Medium Grained Sand, Brown, Fine to Medium Grained Sand,
With Fine to Coarse Grained Gravel, With Fine to Coarse Grained Gravel,
Stiff, Dry to Moist Stiff, Dry to Moist
1500 1500
1600 |Perc1 Terminated 1600 |Perc2 Terminated
1700 1700
1800 1800
1900 1900
2000 2000
2100 2100
2200 2200
2300 2300
2400 2400
2500 2500
*- DCP restarted down the borehole
PP- Pocket Penetrometer
SS — Shrink-Swell
SWL -Standing Water Level
1SS-indicative Shrink-Sweill
R - Refusal
8/11
Page 13
9/11 [OCR of page images] Introduction The purpose of this report is to classify the site in accordance with AS2870-2011. This report is based on the field investigation/Iab testing and information if any provided by the client. This report relates exclusively to the tested locations and the above-mentioned structure. Further investigation may be required. Bore logging was carried out in accordance with AS1726-2017 Geotechnical Site Investigations. Site Classification Class “P” (Due to uncontrolled fill, poor bearing capacity & trees) Based on the soil profiles the site would have the characteristics of an 'H1' site with an approximate Ys of 40-45mm if not a “P”. Important Notes Relating to the classification. Attached. Allowable Bearing Capacity An approximate bearing capacity of 100kpa was encountered as per the below: * 1200mm below existing ground surface level in the Silty CLAY at BH1. 700mm below existing ground surface level in the Silty CLAY at BH2. This is a suggested founding depth only, greater depth may be required due to the following. Bearing capacity can be highly variable over the allotment these depths are specific to the test locations. Actual founding depth should be nominated by the designing engineer whilst taking construction and footing type, fill, underground services, retaining walls, settlement, proposed cut/fill and any trees into account. 9/11
Page 14
Articulation design can be prepared by the following people:
Illustration Only: Articulated Plumbing Joints • a Registered Professional Engineer of Queensland with relevant competency
• a person who holds a hydraulic services design licence issued by the QBCC under the QBCC cAt
• a person who holds either a trade contractor or nominee supervisor plumbing and or drainage
licence issued by the QBCC under the QBCC Act.
They can only prepare an articulation design for work that is for: o the licensee's personal use, or o
use in drainage work to be performed by the licensee personally.
Due to the specialised nature of articulation design, it is recommended that practitioners are
experienced in this field and are confident in their ability to undertake the work competently.”
10/11
Page 15
11/11
-
o
t-
lL
o
{U E
E l-
5
\t
()
5
3' o
lr dr-
2 2
o
$u C'
td
c'
63 E
o
L
!,
o\1
ts !(t
td
iE
CI
H* UI
-,li H
l-
l-
F
tJ
."
lrl
o
E
a o-
=
6 |o rO
tF
rt
t a
(F 1a- rF
.?
F o a
o 3 a
g ct ct C}
Ut
u
I
l- $
0*
ut i;
$
{
051 il 9d
ln as
=:
HR r inz
l{ut
IFi
F$E
€rt
Appendix A - Inspection Port Installation
t.,;.o
-
J
E
LlE
6
IK
3tr
i5
iE,I
HE
zvt
g,
Ei
.a
1?N
.l
rd h,
l-F
9?
Page 16
. G STRATEGIC STRATEGIC SOLUTIONS, CREATIVE THINKING rgstrategic.com.au