Council archive · source document
Compiled Approved Plans MCU17 0004 04 & REC17 0002.04 · MCU17/0004.04
Plans and drawings: the text below has words only, no drawings.
Very large file (10.8 MB): may take a few minutes to open.
© COPYRIG HT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dim ensions on site before fabrication or set out.
DO NOT COPY in any form or by me ans (graphic, electronic or mechanical,
includin g photocopying) without the written permision of Mercury Design.
SECTION NOTES
8m Above Existing Ground Line
1) CONCRETE SLAB, BLOCKWORK &
Colorbond Custom Orb roof sheeting FOOTING DESIGN TO ENGINEERS
on trusses at 900crs SPECIFICATIONS ON 0.2mm & 50mm
MINIMUM SAND BEDDING
Prefabricated timber roof trusses
Ceiling insulation as per
designed and installed to 2) 200 SERIES BLOCKWORK CORE FILLED
energy report
manufacturer's specifications AND REINFORCED TO ENGINEER'S
Roof SPECIFICATION
8430 Colorbond fascia and gutter, to
Insulation to all light weight selection, fixed to manuf's specs 3) DISCONTINUOUS CONSTRUCTION TO
clad walls as per energy DETAIL WITH 1x13mm GYPROCK
4.5mm FC soffit sheeting fixed to PLASTERBOARD CD & TSB4/ASB4
frame
report
ceiling
2600
2550
38x50mm GOS H3 HWD battens
joinery
WIR BED 1 STUDY BATH BED 3 POLYESTER BATTS AS PER ACCOUSTIC
2100
Colorbond Parapet
22mm Structural particleboard flooring REQUIREMENTS
Capping to match roof
colour on joists at 450mm crs to engineer's 4) PARTY WALLS TO EXTEND TO UNDERSIDE
design OF ROOF SHEET FIRE PROOF MINERAL
First Floor WOOL OVER WHERE NOT PROTUDING
380
5830
5) EXTERNAL BLOCK WALLS RENDERED &
Blockwork wall to engineer's 10mm Plasterboard lining to battens PAINTED TO SELECTION WITH EXPRESSED
design, Rendered & fixed to frame ARTICULATION JOINTS AS SHOWN
painted to selection
frame
ceiling
6) 10mm PLASTERBOARD LINING TO
GARAGE KITCHEN DINING PATIO
2750
2700
joinery
10mm Plasterboard lining to stud frame
2400
INTERNAL 70/90mm STUD PARTITION WALLS
to AS1684.2
7) 10mm PLASTERBOARD LINING ON
Concrete slab & footings to engineer's 28mm METAL BATTENS TO BLOCK WALLS
specifications (NON PARTY WALLS)
Ground Floor
300
2700 8) COLORBOND CUSTOM ORB ROOFING
WITH 75 ANTICON BLANKET OR SIMILAR
Flood Level
INSULATION TO SELECTION OVER METAL
2400
Existing Ground Line PURLINS @900ctrs ON TIMBER TRUSSES TO
MANUFACTURERS SPECIFICATIONS @
900ctrs WITH 10mm PLASTERBOARD
HOUSE 4 SECTION A-A CEILING TO 28mm METAL CEILING
-
A Scale: 1 : 100
BATTENS @450ctrs
NOOSA COUNCIL (NOTE: BATTENS MAY NEED TO BE
INSTALLED @450ctrs TO COMPLY WITH
APPROVED PLAN WORKPLACE HEALTH & SAFETY
REQUIREMENTS IF NO OTHER METHOD OF
MCU17/0004.01, FALL ARREST IS ADDRESSED)
OPW17/0005.01 & REC17/0002 9) COLORBOND GUTTER AND DOWNPIPES
TO MATCH ROOFING TO SELECTION.
4 MAR 2019 Colorbond Custom Orb roof sheeting
on trusses at 900crs
'OPTION' TIMBER OR COLORBOND FASCIA
TO MATCH ROOFING
10) ALL JOINERY AT 2100/2400 HEAD
Prefabricated timber roof trusses HEIGHT (UNO) TO SELECTION
designed and installed to
manufacturer's specifications 11) VERTICAL ALUMINIUM BLADE
SCREENING WITH FINISH TO CLIENT
Colorbond fascia and gutter, to SELECTION.
Roof selection, fixed to manuf's specs
12) TREADS & RISERS TO COMPLY WITH
8430
4.5mm FC soffit sheeting fixed to B.C.A. PART 3.9.1.4
38x50mm GOS H3 HWD battens BALUSTRADE & HANDRAILS TO COMPLY
WITH B.C.A. PART 3.9.1.5
frame
ceiling
Insulation to all light weight clad walls
2600
2550
BATH STUDY BED 2
joinery
2100
as per energy report 13) FULL TERMITE TREATMENT SYSTEM TO
22mm Structural particleboard flooring A.S. 3660 BY LICENCED INSTALLER
7670 at ridge
above EGL
on joists at 450mm crs to engineer's (SYSTEM TO PROVIDE 50 YEAR SERVICE
GUARANTEE)
First Floor design
380
5830 SITE
46-48 ELIZABETH STREET
10mm Plasterboard lining to battens NOOSAVILLE, QLD 4566
fixed to frame PROJECT
10mm Plasterboard lining to stud frame TOWNHOUSE DEVELOPMENT
frame
ceiling
2750
2700
joinery
2400
ALFRESCO DINING LIVING to AS1684.2 CLIENT
46 ELIZABETH Pty Ltd
Concrete slab & footings to engineer's DRAWING TITLE
specifications HOUSE 4 SECTIONS
Ground Floor
300
2700 DESIGNED SCALE
Flood Level B.D.H. 1 : 100
2400 CHECKED STAGE - ISSUE
POOL B.D.H. BA - C
DRAWN DATE
Pool to engineer's design MJ 26.02.2019
PROJECT No. PAGE No.
18070 D36 OF 84
0 1 2 3 4 5m
HOUSE 4 SECTION B-B 1: 100
B Scale: 1 : 100
1 3 0 0 1 3 3 9 1 7
[email protected]
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
26/02/2019 11: 24: 44 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans MCU17 0004 04 & REC17 0002.04Related documentApplication case desk ↗