Council archive · source document
Appendix 1 Gateway Drive Code Assessment Ver1 · MCU15/0031
Attached to the e-mail MCU15/0031 & OPW15/0057 Development Application.
MCU to establish Entertainment and Dining Business (Type 1 Food and Beverage)
MCU to establish Industrial Business – Type 2 Production, Alteration, Repackaging and Repairing
2/18 Duke St Sunshine Beach
Lot 11Gateway Drive, Noosaville
Probable solutions (if code
Specific Outcomes Proposal Outcomes
assessable)
operation is one that is
expected within the industrial
zone. Development to the west
buffers this development and
the nearest residential
development which is located
95m away.
Mechanical plant and equipment and
storage areas S21.1 Mechanical plant and equipment
O21 Mechanical plant and equipment are— Complies – All mechanical
(including air conditioning equipment) and a) located more than 2m from any property plant and equipment will be
storage areas are designed and located to— boundary; located on the ground and
a) avoid adverse visual impacts when b) where located at ground level, screened screened by landscaping as
viewed from the street and adjoining by fencing 1.5m in height or dense provided for in Landscaping
properties; and vegetation of at least 1.5m in width Plan.
b) visually integrate with the building incorporating grouped trees and shrubs
design. with maximum separation distance of 1m
measured from the centre of the tree or
scrub; and
c) are visually integrated into the line and
plane of the building and roof design and
do not project beyond the height or width
of the building when viewed from the
street and adjoining properties;
AND Complies – No material will be
S21.2 For Industrial business and Retail stored external, provision has
business Type 3, materials stored outside of a been made within building
building do not exceed 4m in height or half the design for all storage to occur
height of the on-site buildings whichever is the inside.
greater.
Safety and security
O22 All property boundaries are clearly S22.1 Boundaries are identified by such means Complies - The subject
identifiable with public and private spaces as - property boundaries are
clearly defined. clearly identifiable by fencing,
a) fencing; or
landscaping in place.
b) changes in surface materials or levels; or
c) landscape treatments;
AND Complies - Loading bay and
storage areas are contained
S22.2 Loading and storage areas are well lit or inside the proposed building
can be locked after hours. and will be locked after hours.
O23 All premises and access routes are clearly S23.1 All premises are identified by the Complies- The Proposed
identifiable to all persons, particularly provision of the street number in a prominent development will have signage
emergency services personnel. location, preferably near the site entry, (i.e. on to depict street number which
the kerb or letterbox or by signage on the will be easily viewed.
building or site).
Page 6 of 22
PT010115 VER 1.1 060215
See the original
The page text is free to read. Viewing or downloading an original file needs an account.