Council archive · source document
Weier Group geotech · MCU17/0523
Attached to the e-mail Information response - MCU17/0523.
PO Box 171 Wamuran Qld 4512 296 Old North Road, Wamuran Qld 4512 AGNER Phone: 07 5496 6715 Mobile: 0438 924 637 Fax: 07 5496 6717 Email: [email protected] ABN: 49 416 679 791 Web: www.wagnersoiltesting.com.au SITE CLASSIFICATION REPORT Client: Weier Group Site Address: 26/512 David Low Way, Castaways Beach Qld Proposed Development: New Construction Reference Number: J17/01 Date: 13/03/17 SITE CLASSIFICATION On the basis of our Site Investigation including Borelogs, Dynamic Cone Penetrometers and NATA Accredited Laboratory Analysis, the above site may generally be classified as Class ‘M/P’ in accordance with AS2870 — Residential Slabs and Footings. Predicted Surface Movement (Ys): >20mm Field Moisture Content (%): 4.7 Note: Based upon material composition and reactivity this site would generally be classified ‘M‘ but has been classified ‘M/P‘ due to Inadequate Bearing Capacities. Fill Depth: Approx. 0.4m BH1, 0.3m BH2 Ground Water: Not Encountered Soils: Refer to Borelogs Foundation Material: As Above (All footings to be founded on uniform materials) RECOMMENDATIONS: The above Site Classification has been determined in accordance with AS2870 — Residential Slabs and Footings, and has been based on the current soil profile indicated in the above Geotechnical Report. Additional earthworks on the property, such as cutting or the placement of additional fill material may result in a change in the above Site Classification. The Footing System for the new development is to be designed by an experienced Structural Engineer in accordance with AS2870 — Residential Slabs and Footings, and is to take into account the above Site Classification, all of the information contained within the attached documentation, and possible effects of additional earthworks on the property. The Footing System is to be designed to suit the specific requirements of the proposed new Dwelling, with adequate strength, stiffness and depth to suit the method of construction detailed on the Architectural Drawings. Reference is also to be made to the attached specifications: Appendix 1 — Construction of Slabs on Ground, and Appendix 2 — Placement of Fill Material. The property owner must be made aware of the recommendations contained within CSIRO’s publication, Sheet No. 10 - 91 “Guide to Home Owners on Foundation Maintenance and Footing Performance”, a copy of which is available from our office. This publication provides important information relating to the care of the foundations for the new Dwelling. Notes: Wagner Soil Testing should be contacted at footing excavation stage to confirm soil profiles and bearing capacities relevant to the purpose of this investigation as the selective point boreholes carried out are only assumed indicative of the entire study area until confirmed. This report does not constitute a slope stability assessment. If the local authority deems it necessary, Wagner Soil Testing’s Geotechnical Engineer will need to be consulted. It is the house owner's responsibility to maintain stable moisture conditions near the footings as large changes in moisture conditions around the structure's footings will cause movement which may lead to damage. Run-off/drainage should be diverted around and away from any footing system. This rgport represents an opinion, based upon the balance of probabilities; from the evidence available, in so far as it w ble to be determined within the limitations of the work undertaken; the information provided. Dean Wagner Managing Director BSA No: 1090492/1138578 CONSTRUCTION MATERIALS TESTING
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 8 pages
Page 2
PO Box 171 Wamuran Qld 4512 : 296 Old North Road, Wamuran Qld 4512 AGNER Phone: 07 5496 6715 Mobile: 0438 924 637 Fax: 07 5496 6717 Email: [email protected] ABN: 49 416 679 791 Web: www.wagnersoiltesting.com.au Definitions Definitions to help you understand your report Table 2.1 GENERAL DEFINITIONS OF SITE CLASSES Class Foundation A . Most sand and rock sites with little or no ground movement from moisture changes Slightly reactive clay sites with only slight ground movement from moisture changes Moderately reactive clay or silt sites, which can experience moderate ground movement from moisture changes Highly reactive clay sites, which can experience high ground movement from moisture changes Extremely reactive sites, which can experience extreme ground movement from moisture changes Ato P Filled sites P Sites which include soft soils, such as soft clay or silt or loose sands; landslip; mine subsidence; collapsing soils; soils subject to erosion; reactive sites subject to abnormal moisture conditions or sites which cannot be classified otherwise x; S| w Table 2.3 CLASSIFICATION BY CHARACTERISTIC SURFACE MOVEMENT Surface Movement Primary classification of site Ys < 20 mm Slightly reactive (S) 20 mm < Ys < 40 mm Moderately reactive (M) 40 mm < Ys < 60 mm Highly reactive (H1) 60mm <Ys <75mm Highly reactive (H2) Ys > 75 mm Extremely reactive (E) Characteristic surface movement (Ys) is the vertical movement range expected during the life of the house from a reasonable estimate of dry conditions to a similar estimate of wet conditions and does not take into account the moderating effect of the footing system. The Standard nominates 50 years as the ‘life’ of the house and ‘reasonable’ as the level that could be expected for 19 houses out of every 20. The effects of trees, poor site drainage, leaking plumbing and exceptional moisture-induced movements as outlined in Clause 1.3.3 of AS2870 are not taken into account in the calculation of Ys. The purpose of site investigation is to provide sufficient information to enable a site classification to be made, and to include information on the presence and depth of fill material, natural soil profile, and soil reactivity where required. Class A, S, M, H an E sites shall have adequate allowable bearing pressure. The allowable bearing pressure at a foundation level shall be not less than 100 kPa for strip and pad footings, and under the edge footing of footing slabs used without tie bars between the edge footing and slab. The allowable bearing pressure at foundation level shall be not less than 50 kPa under all beams and slab panels and support thickenings for slab construction. CONSTRUCTION MATERIALS TESTING
Page 3
PO Box 171 Wamuran Qld 4512 296 Old North Road, Wamuran Qld 4512 AGNER Phone: 07 5496 6715 Mobile: 0438 924 637 Rs Fax: 07 5496 6717 Email: [email protected] ABN: 49 416 679 791 Web: www.wagnersoiltesting.com.au ENGINEERING LOG Client: Weier Group Job No: J17/01 Project: Site Investigation Date Drilled: 2/03/17 Location: 26/512 David Low Way, Castaways Beach Qld Bore Size: 100mm @ Driller: LW : Drill Type: IH [Ute] Logged By: LW Fluid: N/A Depth | Soil Description/Classification Moisture Consistency | Samples DCP (m) | Location: Borehole 1 Condition | Rel. Density | Type &No_ | Blows 0.0- | Sand [SP], Grey, Fine —- Medium Moist Very Loose 0.4m_ | Grained Sand, Some Fine — Medium Organics. FILL 0.4-— | Sand [SP], Grey Pale Grey, Fine — Moist Very Loose 1.3m | Medium Grained Sand. 1.3- | Sand [SP], Pale Grey, Fine - Medium Dry Loose 2.5m | Grained Sand. Note: Borehole [email protected] (Not Refusal) N22 0 Be aan nn ro 2 a= All classifications as per “Guide to the Description Identification and Classification Of Soils” Table A1, AS1726 [1993]. W29/3 18/10/16 CONSTRUCTION MATERIALS TESTING
Page 4
PO Box 171 Wamuran Qld 4512 296 Old North Road, Wamuran Qld 4512 AER Phone: 07 5496 6715 Mobile: 0438 924 637 RSs Fax: 07 5496 6717 Email: [email protected] ABN: 49 416 679 791 Web: www.wagnersoiltesting.com.au ENGINEERING LOG 1.9m | Grained Sand. Client: Weier Group Job No: J17/01 Project: Site Investigation Date Drilled: 2/03/17 Location: 26/512 David Low Way, Castaways Beach Qld Bore Size: 100mm @ Driller: LW Drill Type: IH [Ute] Logged By: LW Fluid: N/A Depth | Soil Description/Classification Moisture Consistency | Samples DCP (m) | Location: Borehole 2 Condition | Rel. Density | Type &No_ | Blows 0.0-— | Sand [SP], Grey Dark Grey, Fine — Moist Loose 1 0.3m _ | Medium Grained Sand, Fine — 1 Medium Organics. FILL 1 1 0.3-— | Sand [SP], Grey Pale Grey, Fine — Moist Loose 1 0.9m | Medium Grained Sand. 1 1 0.9-— | Sand [SP], Pale Grey, Fine — Medium Moist Loose Sample for 1 1.2m | Grained Sand. Lab Analysis 2 1 1.2— | Sand [SP], Pale Grey, Fine - Medium Dry Loose 2 2 2 2 1.9-— | Sand [SP], Pale Grey, Fine - Medium | Dry - Moist Loose 2.5m | Grained Sand. Note: Borehole [email protected] (Not Refusal) All classifications as per “Guide to the Description Identification and Classification Of Soils” Table A1, AS1726 [1993]. W29/3 18/10/16 CONSTRUCTION MATERIALS TESTING
Page 5
CAGNER ES ABN: 49 416 679 791 PO Box 171 Wamuran Qld 4512 296 Old North Road, Wamuran Qld 4512 Phone: 07 5496 6715 Mobile: 0438 924 637 Fax: 07 5496 6717 Email: [email protected] Web: www.wagnersoiltesting.com.au Client Weier Group Project 26/512 David Low Way Castaways Beach Qld Job No | J17/01 Date 2/03/17 Stormwater 13m ab 15° BH1<” 6m BH2 12° ‘ > 4b 5m wy we 7.5m Boundary Access Street David Low Way Remarks: e Dirt Block with Moderate — Steep Slope e Bush Land Behind Block 15-03-03 CONSTRUCTION MATERIALS Sketch Not To Scale W13/1 TESTING
Page 6
PO Box 171 Wamuran Qld 4512 296 Old North Road, Wamuran Qld 4512 AGNER Phone: 07 5496 6715 Mobile: 0438 924 637 RS Fax: 07 5496 6717 Email: [email protected] ABN: 49 416 679 791 Web: www.wagnersoiltesting.com.au TYPICAL SITE CONDITIONS Weier Group 26 / 512 David Low Way, Castaways Beach Qld CONSTRUCTION MATERIALS TESTING
Page 7
PO Box 171 Wamuran Qld 4512 296 Old North Road, Wamuran Qld 4512 Phone: 07 5496 6715 Mobile: 0438 924 637 Fax: 07 5496 6717 Email: [email protected] Web: www.wagnersoiliesting.com.au (T)AGNER Elo ABN: 49 416 679 791 Information Important Information about your Report As a client of Wagner Soil Testing Pty Ltd you should know that site subsurface conditions cause more construction problems than any other factor. These notes have been provided to help you interpret and understand the limitations of your report. Your report is project specific Your report has been developed on the basis of your unique project specific requirements as understood by Wagner Soil Testing and applies only to the site investigated. Project criteria typically include the general nature of the project; its size and configuration; the location of any structure on the site; other site improvements; the presence of underground utilities; and the additional risk imposed by scope-of-surface limitations imposed by the client. Your report should not be used if there are any changes to the project without first asking Wagner Soil Testing to assess how factors that changed subsequent to the date of the report affect the report’s recommendations. Wagner Soil Testing cannot accept responsibility for problems that may occur due to changed factors if they are not consulted. Our report does not take into account any existing filled ground or any other unforeseen subsurface conditions that may change anticipated site classification. Subsurface conditions can change A geotechnical engineering report is based on conditions that existed at the time the study was performed. Do not rely on a geotechnical engineering report whose adequacy may have been affected by: the passage of time; by man- made events, such as construction on or adjacent to the site; or by natural events, such as floods, earthquakes, or groundwater fluctuations... Always contact Wagner Soil Testing before applying the report to determine if it is still reliable. A minor amount of additional testing or analysis could prevent major problems. Interpretation of factual data Site assessment identifies actual subsurface conditions only at those points where samples are taken and when they are taken. Data derived from literature and external data source review, sampling and subsequent laboratory testing are interpreted by geologists, engineers or scientists to provide an opinion about overall site conditions, their likely impact on the proposed development and recommended actions. Actual conditions may differ from those inferred to exist, because no professional, no matter how qualified, can reveal what is hidden by earth, rock and time. The actual interface between materials may be far more gradual or abrupt than assumed based on the facts obtained. Nothing can be done to change the actual site conditions which exist, but steps can be taken to reduce the impact of unexpected conditions. For this reason, owners CONSTRUCTION MATERIALS should retain the services of Wagner Soil Testing through the development stage, to identify variances, conduct additional tests if required, and recommend solutions to problems encountered on site. Your report will only give preliminary recommendations Your report is based on the assumption that the site conditions as revealed through selective point sampling are indicative of actual conditions throughout an area. This assumption cannot be substantiated until project implementation has commenced and therefore your report recommendations can only be regarded as preliminary. Only Wagner Soil Testing, who prepared the report, is fully familiar with the background information needed to assess whether or not the report's recommendations are valid and whether or not changes should be considered as the project develops. If another party undertakes the implementation of recommendations of this report there is a risk that the report will be misinterpreted and Wagner Soil Testing cannot be held responsible for such misinterpretation. Your report is prepared for specific purposes and persons ; To avoid misuse of the information contained in your report it is recommended that you confer with Wagner Soil Testing before passing your report on to another party who may not be familiar with the background and purpose of the report. Your report should not be applied to any project other than that originally specified at the time the report was issued. It is a requirement that the client contacts Wagner Soil Testing Pty Ltd when the exact position of the proposed building is confirmed so we can check if our Boreholes fall in the footing area [our borelogs are only presumed indicative of the whole area until this is confirmed]. In the case of a cracked house investigation more testing may be required to conclude all possible causes of settlement and or movement. Initial drilling and lab testing may only identify some of the causes of the problem. Wagner Soil Testing should be contacted when additional testing is required. It is a company policy that Wagner Soil Testing are contacted if the development (including any portion and/or envelope) is sold and/or changes title as the report is only for the use of our direct client. If the development is sold and/or changes title Wagner Soil Testing must be contacted and subsequently will carry out a comprehensive site inspection — evaluation at no cost to ensure the preliminary report is relevant and no changes whatsoever have been made. TESTING
Page 8
APPENDIX 1: CONSTRUCTION SPECIFICATION FOR SLABS ON GROUND 1. Site Preparation All vegetation and top soil that contains grass or trees roots and any rubbish shall be removed from the site prior to the commencement of construction. Following stripping of the site, the building platform is to be compacted and proof-rolled to ensure that no loose material is present on the surface. If necessary, any material which cannot be adequately compacted shall be removed, then replaced with a suitable material which can be compacted to the standard specified. If the site is to be “Cut-and-Filled”, then the construction of the footing beams and the placement of the fill material shall be in accordance with the requirements of Appendix 2: Specification for Placement of Fill Material. The foundation under the floor shall be poisoned against termites in accordance with the Tequirements of the Local Authority and the Building Code of Australia. 2. Polythene Membrane A layer of high-impact polythene sheeting shall be provided under all floor slabs. The membrane shall be continuous under the slab and internal footing beams and shall be terminated at the edge beams as indicated on the Footing System drawings. The membrane is to be taped at all joints with a 200 mm minimum overlap and shall be loosely place in the excavated footing trenches to allow the sheeting to conform totally to the width and the depth of the beam once the concrete is placed. 3. Reinforcement All steel reinforcement shall conform to the requirements of AS1302 and AS1304. The reinforcement shall be supported on plastic bar chairs to ensure that the specified cover to all sides is achieved and maintained during placement and compaction of the concrete. Minimum laps for reinforcement shall be as follows: Slab Fabric - 225 mm minimum overlap of “cross-bars” at all edges (r 400 overlap without any “cross-bars”) Trench Mesh - 500 mm splices in all footing beams. - Laps at intersections shall be shown on the Footing System Drawings. Reinf.Bars - 500 mm splices in all footing beams - Provide “L” bars at all beam intersections with min. 500 mm laps to each leg. Cover to reinforcement shall be as follows: - 25 mm to the upper face of internal slabs. - 40 mm to the upper face for external exposure. - 30 mm to the polythene membrane in contact with the ground. - 40 mm to unprotected ground. * 4. Alternative Reinforcement Details Slab Mesh - Deformed Wire Fabrics equivalent to LSDF 752 by “Neumann Steel” may be substituted for F82 mesh (similarly, LSDF 652 Deformed Wire Fabric may be substituted for F72 Mesh). Ligatures - 10mm diameter Deformed Wire ligatures by “Neumann Steel” (FSY = 500 MPa), at 1000 mm max crs. - Y12 deformed bars at 1000 mm crs. 5. Concrete Concrete shall have a minimum 28 day compressive strength of 20 MPa, with an 80 mm slump and a 20 mm maximum nominal aggregate size. All concrete must be well compacted to ensure that all entrapped air is removed and that the concrete is worked around the reinforcement and into all corners. This is easily achieved by the use of mechanic al vibrators. In order to minimise shrinkage cracking of the concrete, the slab may be “cured” to retain the moisture in the concrete for as long as possible. The most convenient method of curing is to use an approved spray-on curing compound which is applied after the concrete has been placed and levelled and has reached its initial set. The curing compound allows continued access to the slab during the curing process, however, care must be taken to avoid damage to the membrane resulting from excessive construction traffic. 6. Thickenings under Bracing Walls Slab thickenings under bracing walls have not been specified, as this information requires that an assessment be made of the wind loading on the structure, which is outside the scope of this report. It is the responsibility of the designer of the structure to specify the location and type of all bracing walls. Where a bracing wall is fixed to the floor slab with a bolt, then the slab shall be locally thickened to 150 mm thick for a distance of 150 mm on all sides of the bolt. 7. Shrinkage Control Long Slabs(<25m) - F82 reinforcing mesh should be provided for slabs over 18 metres in length if shrinkage cracking is to be minimised. Alternatively, Deformed Wire Fabrics equivalent to LSDF 752 by “Neumann Steel” may be substituted for F82 reinforcing mesh (similarly, LSDF 652 Deformed Wire Fabric may be substituted for F72 reinforcing mesh). Re-entrant Steel - Additional reinforcement (2 metres in length) shall be place diagonally across the potential crack at all re-entrant corners, comprising either: - 2 layers of 3— 8TM trench mesh, or - 1 layer 3-11TM trench mesh, or - 3 —Y12 reinforcing bars. Placement of Tiles - Where floor slab is to be tiled, in order to minimise the effects of shrinkage, the following recommendations are made: - F92 slab mesh (or equivalent) should be provided in the area to be tiled. - Cure the slab by keeping it wet (or sealed) for at least 7 days. - Placement of tiles should be delayed for as long as possible (preferably for at least 3 months) - Use a rubber-based adhesive when laying the tiles.
Page 9
APPENDIX 2: SPECIFICATION FOR PLACEMENT OF FILL MATERIAL Where the proposed development is to be supported on fill material that is placed after the completion of the site testing, then the fill shall be placed in accordance with the following recommendations. 1. The site is to be stripped of all vegetation and all topsoil containing grass or trees roots. Following striping of the site, the building platform is to be compacted and proof-rolled to ensure that no loose material is present on the surface. If necessary, any material which cannot be adequately compacted shall be removed, then replaced with a suitable material which can be compacted to the standard specification. 2. Footing Beams at Edge of Slabs (beams supporting load-bearing walls, external walls or roof loads) shall be supported as follows: (a) Beams shall be founded at least 100 mm into the specified foundation material and not less than 300 mm below the finished surface. Where the depth of fill is too large, it may be more economical to support the beam son mass concrete piers, founded 200 mm below the original surface on a sound foundation (either dense sand, firm clay or decomposed rock). The piers shall be either: e 450mm diameter, bored with the Bobcat, and located under all corners of the edge beam and at 1800 mm maximum centres between, or e 1000 mm long x full trench width, excavated with the backhoe and located under all corners of the edge beam and at maximum 3000mm centres between. (b) Alternatively, the Footing Edge Beam may be founded on “Controlled Fill” as specified in Note 5 below. 3. Strip Footings shall be supported either: (a) min. 100 mm into natural undisturbed material with an allowable bearing capacity of at least 100 kPa, or (b) For Class “‘A’ and Class ‘S’ sites only, on “Controlled Fill” as specified in Note 5 below. 4. Footing Slabs, Internal Beams and Load Bearing Support Thickenings shall be supported either: (a) min. 100 mm into natural undisturbed material with an allowable bearing capacity of at least 50 kPa, or (b) on “Rolled Fill” as specified in Note 6 below. Compaction Standards for Fill Material NOTE: All fill material shall be clean and granular and free of organic matter. 5. Controlled Fill (a) Sand Fill up to 800 mm deep, placed in maximum 300 mm layers and compacted with a vibrating roller to achieve a minimum Dynamic Cone Penetrometer reading of 7 blows per 300 mm penetration (refer AS1289.F3.3). Sand fill may be flooded if necessary to achieve this compaction standard, provided the moisture can be subsequently drained from the site. (b) Non-Sand Fill up to 400 mm deep, placed in maximum 150 mm layers and compacted with a mechanical roller. Clay fill should be moist during compaction. (c) Controlled Fill shall continue for at least 1 metre past the edge of the footing beam and shall be battered back to the original surface with a slope of no more than | : 2 (Vert : Hor) (d) Where the depth of fill material exceeds that specified above, the fill material shall be compacted as follows: e Sand Fill - to 65 % Density Index — AS1289.E7.1 e Non-Sand Fill - to 95% Maximum Dry Density (‘Standard Compaction) — AS12891.E4.1 Compaction tests shall be carried out on each layer as fill is placed. If the compaction standard specified is not achieved, then a “Pier and Slab” and ‘Pier and Beam” footing design will be required with all pairs founded on the underlying natural material. 6. Rolled Fill (a) Sand Fill up to 600 mm deep, placed in maximum 300 mm layers and compacted by repeated rolling with an excavator. (b) Non-Sand Fill up to 300 mm deep, placed in maximum 150 mm layers and compacted by repeated rolling with an excavator. (c) Where the depth of fill material exceeds that specified above, the fill material shall be compacted as follows: e Sand Fill - to 65% Density Index — AS1289.E7.1 e Non-Sand Fill - to 95% Maximum Dry Density (Standard Compaction) — As 1289.E4.1 Compaction tests shall be carried out on each layer as fill is placed. If the compaction standard specified is not achieved, then a “Pier and Slab” and ‘Pier and Beam” footing design will be required with all pairs founded on the underlying natural material.
Used in these records
Weier Group geotech.pdfRelated documentApplication case desk ↗