Tod Consulting - Civil Plans v2 · 132003.221172.A
Attached to the e-mail Change to DA - 132003.221172.A.msg.
Plans and drawings: the text below has words only, no drawings.
SETOUT POINTS SERVICE CAUTION CAUTION DANGER
POINT EASTING NORTHING LEVEL LOCATIONS WATER MAIN TELCO ASSETS OVERHEAD
BEFORE YOU DIG ELECTRIC CABLES
1 1007.037 2991.139 46.201
NEW CONCRETE DRIVEWAY CROSSOVER
GENERALLY IN ACCORDANCE WITH SAW CUT EXISTING AC 2 1007.029 2994.946 46.307
It is the responsibility of the
Foreman to contact the relevant
service authorities to ascertain
elstra
IPWEAQ STD DRGS RS-049 & RS-050 3 1007.019 2998.968 46.424 the exact location of services energex
prior to construction.
4 1007.010 3002.883 46.608
01 02 PAVEMENT REINSTATEMENT.
- - REFER TYPICAL ROAD SECTION. 5 1007.001 3006.797 46.770
ELANDA STREET
JOIN NEATLY GENERAL NOTES
JOIN NEATLY
TO EXISTING TO EXISTING 1. DO NOT SCALE DRAWINGS.
2. ALL DISCREPANCIES SHALL BE REFERRED TO THE SUPERINTENDENT FOR CLARIFICATION BEFORE PROCEEDING.
01 02 03 04 05 3. THE CONTRACTOR SHALL NOTIFY THE SUPERINTENDENT IN WRITING OF ALL VARIATIONS ARISING FROM THE CLARIFICATION OF THE
DISCREPANCY.
4. THE CONTRACTOR SHALL SUBMIT DETAILS OF ANY ADDITIONAL COST ARISING FROM A VARIATION TO THE SUPERINTENDENT FOR
APPROVAL, BEFORE PROCEEDING WITH THE WORKS.
5. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS, CURRENT RELEVANT AUSTRALIAN
STANDARDS, OTHER STATUTORY REQUIREMENTS AND TO THE SATISFACTION OF THE LOCAL AUTHORITY AND THE ENGINEER.
6. NO WORK IS TO COMMENCE ON SITE UNTIL THE APPROVAL OF THE COUNCIL HAS BEEN RECEIVED IN WRITING AND AN OFFICIAL
4.000 PRE-START MEETING WITH A REPRESENTATIVE OF COUNCIL AND THE ENGINEER HAVE BEEN HELD. THE CONTRACTOR IS TO OBTAIN
TRANSITION SMOOTHLY NEW 1.2m WIDE CONCRETE PATH A COPY OF THE MINUTES OF THE PRE-START MEETING AND SHALL COMPLY WITH THE REQUIREMENTS THEREOF.
FROM EXISTING WIDTH AS PER IPWEAQ STD DRG RS-065
7. ALL CONSTRUCTION SHALL COMPLY WITH THE RELEVANT WORK PLACE HEALTH AND SAFETY LEGISLATION.
8. WORKING HOURS, COMMUNICATIONS PROTOCOLS, SITE ACCESS, AREA FOR CONTRACTORS FACILITIES/STORAGE AND SITE
SECURITY TO BE AGREED WITH THE PRINCIPAL AND SUPERINTENDENT.
9. THE CONTRACTOR SHALL PROVIDE ALL MANAGEMENT PLANS, INCLUDING TRAFFIC MANAGEMENT PLAN, ENVIRONMENTAL
MANAGEMENT PLAN AND WORK PLACE HEALTH AND SAFETY PLAN FOR REVIEW AND APPROVAL OF PRINCIPAL AND
NEW PAVED DRIVEWAY ON SUPERINTENDENT, PRIOR TO CONSTRUCTION.
CONCRETE SUBSTRATE. 10. FOLLOWING COMPLETION OF THE WORKS THE CONTRACTOR SHALL CLEAN UP THE SITE AND DEMOBILISE TO THE SATISFACTION OF
REFER DRIVEWAY PROFILE. THE PRINCIPAL AND SUPERINTENDENT.
SURVEY
1. THIS DESIGN IS BASED ON SURVEY PROVIDED BY MARTOO CONSULTING PTY LTD.
2. ALL LEVELS ARE TO AUSTRALIAN HEIGHT DATUM (AHD).
BUILDING OVERHANG
3. THE CONTRACTOR SHALL CONFIRM EXISTING LEVELS, FEATURES AND UTILITIES PRIOR TO CONSTRUCTION.
M1 K&C AS PER NSC STD DRG 9001 1.2m WIDE
0.615 CONC PATH 0.5 1.0 2.3 NOM 4. ALL ELEMENTS OF PROPOSED WORK TO BE SETOUT AND CHECKED BY THE CONTRACTOR'S LICENSED SURVEYOR AND ANY
GRATED DRAIN AS PER DISCREPANCIES ARE TO BE REPORTED TO THE SUPERINTENDENT.
SETOUT POINT
PAVEMENT TO MATCH EXISTING IPWEAQ
30mm AC WEARING COURSE (MIN) STD DRG
125mm BASE COURSE (MIN) MIN 75mm EXISTING SERVICES
RS-065
125mm SUB-BASE COURSE (MIN) TOPSOIL & TURF 1. THE LOCATION OF ALL IN-GROUND AND OVERHEAD SERVICES HAS BEEN DETERMINED FROM FIELD SURVEY, DIAL BEFORE YOU DIG
ENQUIRIES AND INFORMATION PROVIDED BY THE SERVICE PROVIDERS / AUTHORITIES.
RP BDY
0% 20mm FALL -5%
MATCH EXISTING CROSSFALL vvvvvv v v v v v v v v v1 : 6 2. THE SERVICES ARE SHOWN ON THESE DRAWINGS FOR INFORMATION ONLY AND NO RESPONSIBILITY IS TAKEN FOR THE ACCURACY
vv v vv v
v vvvv OR COMPLETENESS OF THE INFORMATION SUPPLIED.
vv v v 1 : 4
vvvv
NATURAL SURFAC vv v vv v 3. NOT ALL EXISTING SERVICES HAVE NECESSARILY BEEN IDENTIFIED AND SHOWN ON THE DRAWINGS.
E vvvv
vvvv
v vv v 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING SERVICES ON THE SITE PRIOR TO COMMENCING WORKS.
JOIN TO EXISTING
AS PER IPWEAQ SUBSOIL DRAIN AS PER IPWEAQ STD DRG R140. 5. EXISTING VALVES, HYDRANTS, PITS, ACCESS CHAMBERS AND OTHER UTILITIES SHALL BE MODIFIED WHERE NECESSARY TO SUIT
STD DRG R170 CONNECT TO EXISTING SUBSOIL IF PRESENT. FINAL FINISHED SURFACE LEVELS.
PROPOSED SECTION 01 TYPICAL ROAD SECTION
DUPLEX 1:50 (A1) 1:100 (A3) - PAVER DEPTH DRIVEWAY PAVING.
REFER ARCHITECT'S DRAWINGS.
SL82 MESH
125
CONC DRIVEWAY
125
CONC SUBSTRATE
300
EDGE THICKENING SL82 MESH
10mm FULL DEPTH COMPRESSIBLE R16-450 S.S. GRADE 316 DOWEL BARS,
MATERIAL WITH A 10 x 10 SEALANT 400 LONG, IN DOWEL FORM SLEEVES
REFER GOCKEL ARCHITECTS WITH 16mm INSERTS ON BAR CHAIRS
FOR BUILDING DETAILS
DRIVEWAY INTERFACE DETAIL
STORMWATER DRAINAGE INFILTRATION NOT TO SCALE
TRENCH (INDICATIVE LOCATION ONLY).
15 NO. ATLANTIS DOUBLE FLO-TANKS
AS PER SWMP (3425 x 1224mm).
'RL' : REPRESENTS FINISHED SURFACE LEVEL
CH 0.000
RL 46.659
CH 0.275
RL 46.629
CH 1.215
RL 46.769
CH 2.415
RL 46.789
BUILDING
B DRIVEWAY PAVING ON NOM RL 47.5
RP BDY
CH 5.415
RL 46.339
REFER DRIVEWAY CONCRETE SUBSTRATE.
INTERFACE DETAIL REFER ARCHITECT'S
DRAWINGS FOR DETAILS.
HEADROOM
STORMWATER DRAINAGE INFILTRATION
2.7m MIN
TRENCH (INDICATIVE LOCATION ONLY).
FP FRONT
CH 10.052
RL 45.180
SAW CUT
FP BACK
K&C INV
12 NO. ATLANTIS DOUBLE FLO-TANKS
K&C LIP
1:4
AS PER SWMP (2740 x 1224mm).
CH 13.052
RL 44.800
REFER TYPICAL
B ROAD SECTION
3.0m CURVED TRANSITION
NATURA
L
SURFAC
E
PROPOSED NEW EASEMENT
125mm THK CONCRETE DRIVEWAY 125mm THK 25MPa CONCRETE SUBSTRATE ON GARAGE
CROSSOVER GENERALLY IN ACCORDANCE COMPACTED CBR15 GRAVEL BASE (100mm MIN)
J:\2018\18505BD2_Duplex_61_Elanda_St_Sunshine_Beach\4.CADD\#ACAD\18505_CIVIL.dwg
WITH IPWEAQ STD DRGS RS-049 & RS-050 WITH KEYED CONTROL JOINTS AT 6m CRS &
REINFORCED WITH SL82 MESH GRATED
3.0m CURVED TRANSITION DRAIN
SECTION 02 DRIVEWAY PROFILE
1:50 (A1) 1:100 (A3) - 0 1 2 3 4 5m 0 0.5 1 1.5 2 2.5m
GENERAL ARRANGEMENT
1:100 (A1) 1:200 (A3) 1:50 (A1) 1:100 (A3)
SCALE 1:100 (A1) 1:200 (A3)
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
This drawing is subject to SURVEYOR JF DR
copyright in accordance with the
MARTOO CONSULTING PTY LTD
WADE JENNER Designed Verified
61 ELANDA ST, SUNSHINE BEACH
GENERAL ARRANGEMENT AS SHOWN A1
agreement between Tod
Consulting pty ltd (tc) and tc's
client. This drawing shall only be
(07) 5447 2500 JF DR PROPOSED DUPLEX DEVELOPMENT
AND DETAILS Drawing Number
Approved RPEQ No
used for this specific project. ARCHITECT
DOUG REYNOLDS 9072 RDP LOT 408 RP48112 18505-C001
This drawing shall not be used GOCKEL ARCHITECTS Noosa: 07 5449 9600 LOCAL AUTHORITY NOOSA
B 26.02.18 INFILTRATION TRENCH DETAILS JF David Gockel 0488 112 219 Sunshine Coast: 07 5329 3190 Mackay: 07 4840 2337
Signed MCU APPROVAL HORIZ DATUM LOCAL 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566
A 15.02.18 ORIGINAL ISSUE JF ROL APPROVAL VERT DATUM AHD (OPM44260)
'issued for construction' in the
revision description. Rev Date Revision Description Drawn
[email protected] www.todconsulting.com
ABN 39 128 805 336
26.02.18 OPW APPROVAL RL DATUM RL 49.843 MEASUREMENT BAR - INCREMENTS IN mm
1 of 1 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Tod Consulting - Civil Plans v2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 259 KB (small file)
- File type
No other editions are linked here.