07/0012 - Response to Information Request [As Published] · 132007.12
tiny © 2006 - TTM Consulting (SC) Pty Ltd Project No: 51078 2. Noise Measurement 21 Equipment The following equipment was used to measure and record existing ambient noise levels in the vicinity of the site: «Lutron SC-941 Acoustic Calibrator « ARL 315 Environmental Noise Logger. Calibration certification is current for all equipment used, and the noise logger was field calibrated before and after use with no significant difference in level. 2.2 Unattended Monitoring A logger was located along the north west site boundary adjacent to 18 June Crescent, and was set to record noise statistics in 15 minute intervals between the 22" and 26" of March 2007. The statistical interval was chosen to allow application of AS/NZS 1055.1 - 1997 ‘Acoustics - Description and Measurement of Environmental Noise’. Weather conditions during the survey were clear with light to moderate wind. Table 1 Ambient noise levels measured at the site Measured Noise Level Time Period Lso, dB(A) Lio, dB(A) Li, dB(A) Day 7:00 - 18:00 48 54 61 Evening 18:00 - 22:00 42 43 57 Night 22:00 - 07:00 36 43 48 www. itmgroup.com.au wr” T: (07) 5479 2455 F: (07) 5479 3651 E: [email protected] Page 3