Attachment A Revised proposal plans · 132007.2446.03
Attached to the e-mail Response to information request - 132007.2446.03.
Plans and drawings: the text below has words only, no drawings.
ELEVATED ROOF
ELEVATED ROOF OVER BUNK ROOMS
OVER BUNK ROOM EXISTING EXISTING ROOFLINE
1.0M WIDE TO MANAGER'S UNIT
LANDSCAPING STRIP 5° ROOF
ceiling 2
ceiling 1
2700
2400
2700
2400
upper floor
680
floor level
LANDSCAPING STRIP NEW 2000 HIGH RENDERED
WALL WITH INSERTS EASTERN ELEVATION
PACIFIC AVENUE ELEVATION SCALE 1 : 100
SCALE 1 : 100
PAINT FINISH ELEVATED ROOF 1.0M WIDE LANDSCAPED
EXISTING ROOFLINE TO MATCH EXIST . HOSTEL OVER BUNK ROOMS BUFFER TO BOUNDARY
TO MANAGER'S UNIT
ceiling 2
ceiling 1
2700
2400
2700
2400
upper floor
PUBLIC floor level
FOOTPATH
NORTHERN ELEVATION
SCALE 1 : 100
LANDSCAPING
STRIP ROOFED COMMUNAL AREA EXISTING ROOFLINE ELEVATED ROOF OVER BUNK ROOMS
5° PITCH EXISTING ROOFLINE
TO MANAGER'S UNIT
ceiling 2
ceiling 1
2700
2400
2700
2400
upper floor
680
floor level
PAINT FINISH TO
SCREENED BIN AREA MATCH EXISTING HOSTEL
SOUTHERN ELEVATION
SCALE 1 : 100 FOR INFORMATION ONLY
NOT FOR CONSTRUCTION
Drawing Revisions Construction Notes
All construction to be in accordance with the current BCA, Qld Building Act,
Client TAMOBROJO PTY LTD Title
ELEVATIONS - SHEET 1
PJ
Note: * indicates signatures on original issue of drawing or last revision of drawing
relevant Aust. Stds, QDC and relevant Local Govt reqts.
Builder or contractor is to verify all dimensions and details before the
commencement of any work and notify designer of any discrepancies. concepts Project NOOSA FLASHPACKERS,
All dimensions shown in millimetres u.n.o.
& designs HOSTEL 102-106 PACIFIC AVE
Do not scale off drawings. Scale 1 : 100 DO NOT SCALE
Drawn JG Designed Original Size
Drawing No:
PJ concepts & design Pty Ltd PH. 0438 945 935 Drafting Design
A3
P ISSUED FOR INFORMATION JG POD 09.07.18 Conditions of Use. This document may only be used by PJ's client (and any other
person who PJ concepts & designs has agreed can use this document) for the PH. 0410 627 589 ABN 80 130 019 288
Check Check
This Drawing must not be used for Construction unless signed as Approved 18101-04
No Revision Drawn Checked Date
purpose for which it was prepared and must not be used by any other person or for
any other purpose.
E. [email protected] QBCC LIC 1264 308
Approved Date 05.07.18 Rev: P
Plot Date: 9/07/2018 12:11:29 PM Cad File No: Z:\PJ CONCEPTS & DESIGNS\Flashpackers\FLASHPACKERS.rvt
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment A Revised proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.