Attachment 9- Amended Bushfire Assessment Report MCU12/0208

of 77

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (11.7 MB): the original may take a few minutes to open or download. The page text below is quick to read.

Noosa on Weyba
Bushfire Assessment Report



Table 5-2          Noosa Plan Natural Hazards Overlay Code compliance assessment
Specific Outcomes                           Probable Solutions                            Noosa on Weyba Response

13.33 Effects of use and works
New Uses

O4 The proposed use does not                S4.1 The use is sited on land that is not     Complies: For the reasons
compromise the safety of people or          in a Medium or High Bushfire Hazard           specified in Section 4, the
                                                 38
property from bushfire.                     Area ; or                                     proposed use does not
                                                                                          compromise the safety of people
                                            S4.2 The use is sited on land that is         or property from bushfire.
                                            determined as low bushfire risk by a site
                                                                                  39
                                            specific bushfire hazard assessment.


Protection of Infrastructure and
Community Uses

O5 Community Uses and                       S5.1 Community Uses and Infrastructure        Not Applicable: The Noosa on
Infrastructure Uses, including that         Uses are not located in a High or Medium      Weyba project does not involve
identified below, are able to function      Bushfire Hazard Area identified on            any Community Uses or
effectively during and immediately          Overlay Maps OM1.4 to OM9.4;                  Infrastructure Uses.
after bushfire events—                      OR
a) Emergency service facilities;            S5.2 Building work will not involve more
                                                                    2
b) Hospitals;                               than an additional 20m of gross floor
c) Education Type 4 uses, including         area to an existing building;
stores for valuable records or items        OR
of historic or cultural significance; and   S5.3 Where located in a High or Medium
d) Service and utility uses, including      Bushfire Hazard Area identified on
electricity substations, major              Overlay Maps OM1.4 to OM9.4, uses are
electrical depots and water treatment       designed to function effectively during
                                                                                    40
plants.                                     and immediately after bushfire events .

Hazardous materials

O6 Public safety and the environment        S6.1 Hazardous materials are not              Not Applicable: The Noosa on
are not adversely affected by the           manufactured and stored on the site.          Weyba project does not involve
detrimental impacts of bushfire on                                                        any hazardous materials
hazardous materials manufactured or                                                       manufacture or bulk storage.
stored in bulk.
13.34 Siting, design and construction
O7 Uses and works including                 S7.1 Uses and works including building        Complies: As detailed in Section
building works are sited, designed          works are sited—                              4 herein the Noosa on Weyba
and constructed to—                                                                       project complies with S7.1 and
                                                                            2
a) minimise the number of people            a) on lots greater than 2,500m ;              thereby achieves O7.
and property subject to bushfire risk;      i) in locations of lowest hazard within the
and                                         lot (Figure 13.5 provides guidance); and
b) maximise the protection of people        ii) to achieve setbacks from hazardous
and property during the passage of a        vegetation of 1.5 times the predominant
fire front.                                 mature canopy tree height or 10m
                                            whichever is the greater; and
                                            iii) 10m from any retained vegetation
                                            strips or small areas of vegetation; and
                                            iv) so that the elements of the
                                            development least susceptible to fire are
                                            sited closest to the bushfire hazard;
                                                              2
                                            b) on lots 2,500m or less - to maximise
                                                                               37
                                            setbacks from hazardous vegetation

13.35 Water supply for fire fighting
O8 An adequate and accessible               S8.1 For premises not in a water service      Complies. The Noosa on Weyba
water supply is provided for fire           area— each lot has an accessible dam,         development would be serviced
fighting purposes.                          swimming pool or water tank accessible        by a reticulated water supply.
                                            by the fire brigade that contains at least
                                            5,000 litres of water.


Northbrook Corporation Pty Ltd                            Version 2                                           11 October 2013
Bushfire Assessment Report v2.docx                  Commercial in Confidence                                         Page 16

Used in these records

About this file

File size
11.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 9- Amended Bushfire Assessment Report MCU12_0208.pdf · 11.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.