Skip to the record
Search everything, all in one place.

Council archive · source document

Attachment 9- Amended Bushfire Assessment Report MCU12/0208

of 77

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (11.7 MB): the original may take a few minutes to open or download. The page text below is quick to read.

Noosa on Weyba
Bushfire Assessment Report



Specific Outcomes                      Probable Solutions                            Noosa on Weyba Response
                                       iii. have access at each end and in other
                                       locations where necessary;
                                       iv. have passing areas and turning areas;
                                       v. have clearly identified access points
                                       for emergency vehicles; and
                                       vi. are located on public land or within
                                       access easements that are granted in
                                       favour of the Sunshine Coast Regional
                                       Council and the Queensland Fire and
                                                        44
                                       Rescue Service
                                       .
Road network

O12 Roads provide for the safe and     S12.1 Cul-de-sacs or no-through roads         Complies - The Noosa on Weyba
effective evacuation of users of       are not used in the street network            Concept Plan makes provisions
premises and access by Emergency       unless—                                       consistent with S12.1 and S12.2.
services.
                                       a) a perimeter road reserve with a
                                       minimum reserve width of 20m and a
                                       formed width of not less than 6m is
                                       provided; or

                                       b) cul-de-sacs or no-through roads are
                                       provided with fire trails or access
                                       easements, capable of being navigated
                                       by conventional vehicles, that link to
                                       through roads (see Figures 13.3 and
                                       13.4);

                                       AND

                                       S12.2 Roads have a maximum grade of
                                       1 in 8 (12:5%).




Lot design

O13 Lot design and building siting     S13.1 Each residential lot—                   Complies.
minimises bushfire hazard to people     a) includes a house site area,               All of the identified Noosa on
and property having regard to slope,        identified on the plan of subdivision;   Weyba development areas are
aspect, existing vegetation and                                                      consistent with S13.1.
adequate separation from hazardous      b)    is of sufficient size and dimensions
vegetation.                                   to accommodate a dwelling and          All of the identified Noosa on
                                              ancillary buildings and use areas;     Weyba development areas, with
                                                                       2             the exception of the area referred
                                        c)    for lots more than 2,500m —            to below, are consistent with
                                             i. conform with the principles for      S13.2.
                                                house site numbers 1, 2 or 3
                                                                                     As detailed in Section 4.3 herein
                                                shown in Figure 13.5; and
                                                                                     appropriate access/egress
                                             ii. are separated from hazardous        arrangements are provided for the
                                                 vegetation for a distance the       proposed Rural Residential area
                                                                                     forming part of Precinct Four that:

Northbrook Corporation Pty Ltd                        Version 2                                           11 October 2013
Bushfire Assessment Report v2.docx              Commercial in Confidence                                         Page 18

Used in these records

About this file

File size
11.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 9- Amended Bushfire Assessment Report MCU12_0208.pdf · 11.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.