A sensitive receptor is defined as “an area or place where noise is measured”.
The EPP(Noise) states that the objectives are intended to be progressively achieved over the long term.
4.5 Summary and Noise Limits
The relevant noise criteria for this development are:
Noise Immissions onto the development–
○Acoustic Quality Objectives:
– Daytime and Evening: 42 dBA LAeq,adj,1hr, 47 dBA LA10,adj,1hr and 52 dBA LA1,adj,1hr
– Night: 37 dBA LAeq,adj,1hr, 42 dBA LA10,adj,1hr and 47 dBA LA1,adj,1hr
Mechanical Plant Noise Emissions:
○ Leq,adj,1hr ≤ Background L90 plus 5 dBA in the day and evening and background plus 3 dBA in the
night.
8816R01V01.docx 11