Original source · versioned page text
Appendix 9 - Detailed assessment against the Noosa plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnPART 14 – ASSESSMENT CRITERIA FOR DEVELOPMENT FOR A STATED
PURPOSE OR OF A STATED TYPE
Division 16 – Existing Services
Table 14-54 Existing Services
Column 1 Column 2 Column 3
Specific Outcomes Probable solutions Response
(if code assessable)
14.124 Effects of works
Setbacks and easements
O1 Development near a sewer, S1.1 The footing of any structure or Complies
water main, stormwater drain, building is located clear of the zone of The site has existing connections
overland flow path or associated influence but no to all necessary urban services,
structure does not— closer than 1.5m (measured horizontally) including Council’s reticulated
a) adversely affect the function of from infrastructure including sewers, water water supply and sewerage
the service; mains and stormwater structures; disposal systems, stormwater
b) place an additional load on the infrastructure, bitumen sealed
service; and S1.2 No building or structure overhangs roads, electricity and
c) unduly increase future the zone of influence; telecommunications. It is not
maintenance costs. encumbered by any easements.
S1.3 Finished surface levels maintain a The proposal would be sufficiently
minimum of 600mm of cover, but no clear of existing infrastructure.
greater than 3m of cover to the Infrastructure contributions would
underground infrastructure; be provided in accordance with
the Charges Resolution (No. 3)
S1.4 If the existing surface level is altered, 2018.
surface level services including manholes
and inspection points are altered to match
the new surface level.
S1.5 Alterations are constructed in
accordance with Section 4 of PSP5 –
Engineering Design Standards – Roads,
Drainage and Earthworks and applicable
water and sewerage design standards;
OR
S1.6 Existing services are relocated and
the design and construction of the
relocated services is in accordance with
Section 4 of PSP5 –Engineering Design
Standards – Roads, Drainage and
Earthworks and applicable water and
sewerage design standards.
O2 Maintenance access is provided S2.1 For trunk infrastructure a registered N/A
to all sewers, water mains, stormwater easement in favour of Council is created
drains, overland flow paths and over all underground infrastructure located
associated structures. in private property;
S2.2 The width of the easement is the
greater of 3m or the width of the zone of
influence;
S2.3 The easement is centred over the
centreline of the infrastructure.
Part 14 – Assessment Criteria – Codes (The Noosa Plan) Page 16 of 28
See the original
The page text is free to read. Viewing or downloading an original file needs an account.