GENERAL:

~ THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL
ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND
SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS
‘AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT.
‘ALL DISCREPANCIES SHALL BE REFERRED TO THE ARCHITECT
FOR DECISION BEFORE PROCEEDING WITH THE WORK.

‘ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE
WORK SHALL BE VERIFIED BY THE CONTRACTOR BEFORE
CONSTRUCTION AND FABRICATION IS COMMENCED. THE
ENGINEER'S DRAWINGS SHALL NOT BE SCALED.

DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE
FOR MAINTAINING THE STRUCTURE IN A STABLE CONDITION AND
ENSURE NO PART IS OVER-STRESSED.

- WHERE EXCAVATION WORK IS TO BE CARRIED OUT ADJACENT TO
EXISTING FOOTINGS, THE EXACT LEVEL OF THE UNDERSIDE OF
‘THE FOOTINGS SHALL BE OBTAINED BY TEST PITS PRIOR TO
EXCAVATION. UNDERPINNING AND SHORING OF THE STRUCTURE
SHALL BE CARRIED OUT AS DETAILED AND THE EXISTING
STRUCTURE SHALL BE MAINTAINED IN A STABLE AND UNDAMAGED
CONDITION.

WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH
‘THE RELEVANT CURRENT S.A.A. CODES (INCLUDING ALL
AMENDMENTS) AND THE STATUTORY AUTHORITIES’
REQUIREMENTS, EXCEPT WHERE VARIED BY THE CONTRACT
DOCUMENTS.

~ ALL DIMENSIONS ARE IN MILLIMETRES UNLESS STATED
OTHERWISE. ALL LEVELS ARE EXPRESSED IN METRES.

‘THE STRUCTURAL WORK SHOWN ON THESE DRAWINGS HAS BEEN
DESIGNED FOR THE FOLLOWING LIVE LOADS UNLESS NOTED
OTHERWISE.

AREA LIVE LOAD (kPa)
DECKS 2.0
FOOTINGS:

- AN ALLOWABLE BEARING PRESSURE IN NATURAL MEDIUM DENSE
SAND OF 175 kPa HAS BEEN ADOPTED IN THE DESIGN OF
FOOTINGS, TO BE CONFIRMED AT TME OF DETAILED EXCAVATION.

‘ALL FOOTING EXCAVATIONS SHALL BE CLEANED OF LOOSE
MATERIAL AND WATER.

~ SIDES OF FOOTINGS SHALL BE FORMED AS NECESSARY WHEN
EXCAVATED FACE IS NOT STABLE.

‘ALL WALLS AND COLUMNS SHALL BE CONCENTRIC WITH
SUPPORTING FOOTINGS UNLESS OTHERWISE NOTED ON THE
DRAWINGS.

UNLESS APPROVED BY THE STRUCTURAL ENGINEER, EXCAVATIONS
SHALL NOT EXTEND BELOW A LINE DIPPING AT 45 DEGREES AND
AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS.

WHERE FOUNDATION MATERIAL DIFFERS FROM THAT DESCRIBED IN

THE SITE INVESTIGATION REPORT OR LOCALISED SOFT SPOTS ARE

FOUND, THE ENGINEER SHALL BE NOTIFIED AND IF NECESSARY THE
MATERIAL SHALL BE EXCAVATED AND BACKFILLED WITH WEAK MIX
CONCRETE,

CONCRETE:

‘ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE
WITH AS. 3600.

CLEAR CONCRETE COVER TO ALL REINFORCEMENT FOR DURABILITY
SHALL BE AS FOLLOWS UNLESS SHOWN OTHERWISE.

 

 

Exposure Concrete | Cast Cast in Cast in
Classification | Grade Against | Forms and | Forms and
To AS 3600 Ground | Exposed not exposed
A1& AZ Ns 50mm 30mm 20mm)
BI N32 60mm 40mm -
82 Noo 65mm 45mm -

 

 

 

 

 

 

Cover Requirements May Need To Be Increased To Suit Fire Rating.

Exposure Classification Shall Be As Indicated On The Drawing.

DURABILITY REQUIREMENTS FOR CONCRETE.

 

 

 

Exposure Classification | Minimum Maximum W/c
To AS 3600: Cement Content | Ratio

AL& AZ -

81 320

82 390

c 450

 

 

 

 

 

MAX. AGGREGATE SIZE = 20mm
SLUMP = BOmm +/- 15mm (AT POINT OF DISCHARGE)

THE CONTRACTOR IS TO NOTIFY THE STRUCTURAL ENGINEER IN
WRITING OF ANY ADMIXTURES TO BE USED IN THE CONCRETE
MIX. NO ADMIXTURES SHALL BE USED WITHOUT WRITTEN
APPROVAL BY THE STRUCTURAL ENGINEER. CALCIUM CHLORIDE
WILL NOT BE PERMITTED AND SHALL NOT BE USED UNDER ANY
CIRCUMSTANCES.

CONCRETE TESTING - PROJECT ASSESSMENT IS REQUIRED AS
PER AS 1379

‘ALL FORMWORK SHALL CONFORM TO A.S. 3610, RESHORING NOT
PERMITTED.

REINFORCEMENT SYMBOLS:~

R - PLAIN ROUND BAR GRADE R2SON TO A.S.4671
N - DEFORMED BAR GRADE DSOON TO A.S.4671
SL - DEFORMED FABRIC MESH GRADE D5O0L TO A.S.4671

THE NUMBER FOLLOWING THE BAR SYMBOL IS THE NOMINAL BAR
DIAMETER IN MILLIMETRES.

SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF
‘APPLIED FINISHES.

UNLESS NOTED OTHERWISE ALL FORMED EDGES AND CORNERS OF
CONCRETE MEMBERS SHALL HAVE 20mm CHAMFERS.

NO_ PENETRATION, CHASES OR EMBEDMENTS SHALL BE
MADE WITHOUT PRIOR APPROVAL BY THE STRUCTURAL ENGINEER.

REINFORCEMENT IS SHOWN DIAGRAMMATICALLY AND NOT
NECESSARILY IN TRUE PROJECTION.

DO NOT CUT REINFORCEMENT ON SITE TO CLEAR PENETRATIONS.
DISPLACE REINFORCEMENT SLIGHTLY AS NECESSARY TO CLEAR
BLOCKOUTS.

SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE
POSITIONS SHOWN, UNLESS APPROVED BY THE STRUCTURAL
ENGINEER.

WELDING OF REINFORCEMENT |S NOT PERMITTED.

REINFORCEMENT SHALL BE BENT COLD IN ACCORDANCE WITH
‘AS. 3600 EXCEPT WHERE APPROVED BY THE STRUCTURAL
ENGINEER. NO REBENDING SHALL BE PERMITTED UNLESS:
APPROVED BY THE STRUCTURAL ENGINEER.

ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN ITS
CORRECT POSITION DURING CONCRETING BY APPROVED PLASTIC
BAR CHAIRS, SPACERS OR SUPPORT BARS. MAXIMUM

CENTRES OF SUPPORTING CHAIRS SHALL BE 800mm FOR FABRIC,
600mm FOR BARS UP TO 12mm DIAMETER, 900mm FOR BARS 16mm
AND GREATER.

THE FACE OF ALL CONCRETE AGAINST WHICH NEW CONCRETE IS
TO BE CAST IS TO BE THOROUGHLY MECHANICALLY SCABBLED,
FULLY EXPOSING THE AGGREGATE MATRIX.

ALL CONCRETE SURFACES ARE TO BE CURED FOR SEVEN DAYS
AFTER CASTING USING A METHOD APPROVED BY THE
STRUCTURAL ENGINEER.

TIMBER GENERAL:

‘ALL_TIMBER WORK TO BE IN ACCORDANCE WITH:

+ AS 1720.1 TIMBER STRUCTURES CODE.

+ AS 1684 TIMBER FRAMING CODE.

« BUILDING CODE OF AUSTRALIA AND AUSTRALIAN DOMESTIC
CONSTRUCTION MANUAL.

‘ALL TIMBER MEMBERS SHALL CARRY AN INDUSTRY STANDARD
LABEL IDENTIFYING THE STRESS GRADE, SEASONING CONDITION
‘AND TIMBER SPECIES (WHERE APPLICABLE),

CAMBERS AND BOWS TO LINTELS TO BE UP.

BOLTING SCHEDULE:

= EDGE DISTANCES ~ SPACING
M10 - 50mm M10 - 50mm
M12 - 60mm M12 - 60mm
M16 - 80mm Mté - 70mm
M20 -100mm M20 - 80mm

‘ALL BOLTS TO TIMBERWORK TO BE GRADE 4.6/s U.N.O.
(NOT APPLICABLE TO MASONRY ANCHORS & CAST-IN BOLTS)
BOLTS, NUTS & WASHERS TO BE HOT DIP GALVANISED.
BOLT HOLES IN STEEL PLATES SHALL PROVIDE A SNUG FIT
NOT GREATER THAN 0.5mm LARGER THAN BOLT DIAMETER.
WASHERS TO TIMBER:

M12 BOLTS......50sq x 3 THICK

M16 BOLTS.......65sq x 5 THICK

M20 BOLTS.....758q x 5 THICK

M24_BOLTS......85sq x 6 THICK (REFER TO DETAIL DRAWINGS)
‘AT THE END OF THE DEFECTS LIABILITY PERIOD, ALL BOLTED CONNECTIONS
THROUGHOUT ENTIRE PROJECT MUST BE RETIGHTENED.

   
  
 

 

COPYRIGHT - ALL RIGHTS RESERVED
Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.
DISCLAIMER
N12@900 Consulting Engineers accepts no responsibility for
the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900
Consulting Engineers.
DIMENSIONS.

Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

sqD SGD

 

saD

 

 

DRAWN DESIGNED CHECKED.
SEP 18
APPROVED. DATE

 

S.G. DOCHERTY RPEQ No. 6213

 

 

 

 

 

 

1

PRELIMINARY

24.09.18] SGD

 

REV.

 

AMENDMENT

DATE _ | INITIALS

 

 

 

PROJECT

PROPOSED POOL APRON
9 BERRIMA ROW
NOOSA HEADS

 

D. PANKOWSKI

CLIENT

 

ARCHITECT,

 

 

NOTES

DRAWING TITLE

NTeSj0O)

CONSULTING ENGINEERS

 

PH

EMAIL

ACN 129 181 086

ISUNSHINE COAST

0410 599 211

[email protected]
12 Sandy Cove Cre
COOLUM BEACH QLD 4573

 

 

18026

PROJECT No.

DWG No.

S0.01 1

REV.

 

 

 
Full text of the other 5 pages

Page 2

COPYRIGHT - ALL RIGHTS RESERVED

Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.

 

 

a

2

a

4

ZZ
“~ 9 BERRIMA ROW

-~ NOOSA HEADS
a BUP 6343
4 508 SQ. M

   
   

EXISTING
SEWER
MANHOLE

  

EXISTING BUILDING

PROPOSED
POOL
DECK

|
?

 

DISCLAIMER

N12@900 Consulting Engineers accepts no responsibility for
the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900
Consulting Engineers.

DIMENSIONS.

Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

 

 

 

sqD SGD saD
SEP 18

 

 

S.G. DOCHERTY RPEQ No. 6213

0 2000 10000
Liti titi ti)

SCALE 1:200 AT A3

 

 

 

 

 

 

1 PRELIMINARY 24.09.18] SGD
DATE _| INITIALS

 

 

 

 

REV. | AMENDMENT

PROPOSED POOL APRON
9 BERRIMA ROW
NOOSA HEADS

 

PROJECT

D. PANKOWSKI

CLIENT

 

 

ARCHITECT,

SITE PLAN

 

 

 

DRAWING TITLE

NTeSj0O)

CONSULTING ENGINEERS

 

ACN 129 181 086

ISUNSHINE COAST

PH 0410 599 211

EMAIL [email protected]

12 Sandy Cove Cre

COOLUM BEACH QLD 4573

 

 

18026 $1.01 1

DWG No. REV.

 

PROJECT No.

 

Page 3

 

 

FOOTING NOTES
CONCRETE: N32, REINFORCEMENT: AS NOTED

CONCRETE WORK SHALL BE IN
ACCORDANCE WITH A.S. 3600.

AT THE TIME OF INSPECTION, REINF'T
SHALL BE IN PLACE WITH PROVISION
FOR MIN. 60mm COVER FOR FOOTINGS.

REINFORCEMENT LAPS

N12... 500
N16... 650
N20... 800

MESH ..... 2 CROSS WIRES + 25MM

EXISTING TIMBER
SLEEPER RETAINING WALL

EXISTING SEWER \
MANHOLE \

. \

\

CONCRETE PIERS AS =O

DETAILED ye

\

EXISTING CONCRETE Uy
MASONRY RETAINING 1
WALL

EXISTING CONCRETE
MASONRY RETAINING
WALL

 

SLAB & FOOTING PLAN
FOR GENERAL NOTES REFER DRAWING S0.01

DENOTES APPROXIMATE
LOCATION OF EXISTING POST
FOOTINGS

© DENOTES 225@ REINF. CONCRETE

PIER

EXPOSURE CLASSIFICATION
TO AS 3600 IS - B1

2 a
2 a
4 a
7 a
2 a
2 a
<O EXISTING PAVERS
EXISTING BUILDING
EXISTING
CONCRETE
POOL
/
eo

COPYRIGHT - ALL RIGHTS RESERVED
Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.
DISCLAIMER

N12@900 Consulting Engineers accepts no responsibility for
the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900
Consulting Engineers.

DIMENSIONS.

Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

 

 

 

sqD SGD saD
DRAWN DESIGNED CHECKED.
MAY 18
APPROVED. DATE

 

 

S.G. DOCHERTY RPEQ No. 6213

0 1000 5000
Citi ti Ti Ti)

SCALE 1:100 AT A3

 

 

 

 

 

 

1 PRELIMINARY 24.09.18] SGD

 

 

 

 

REV. | AMENDMENT DATE _ | INITIALS

PROPOSED POOL APRON
9 BERRIMA ROW
NOOSA HEADS

 

PROJECT

D. PANKOWSKI

CLIENT

 

 

ARCHITECT,

JFOOTING PLAN

 

 

 

DRAWING TITLE

CONSULTING ENGINEERS

 

ACN 129 181 086

ISUNSHINE COAST

PH 0410 599 211

EMAIL [email protected]

12 Sandy Cove Cre

COOLUM BEACH QLD 4573

 

18026 $1.02 1

 

 

 

PROJECT No. DWG No. REV.

Page 4

 

 

EXISTING ———=ff. 7}

RET AINNG
WALL

 

   
  

NOTED

 

 

 

 

 

 

 

th

CONCRETE PILE AS

1/RB25G GALVANIZED
REID BAR CENTRAL

2250

 

ALL PIERS TO FOUND IN
MEDIUM DENSE SAND OF
ALLOWABLE BEARING
CAPACITY 175KpA

   

PLAN VIEW

PIERS TO FOUND AT BASE OF
ADJACENT RETAINNG WALL AND

INTO NATURAL MATERIAL AS

NOMINATED

CONCRETE PIER DETAILS

1:20 AT A3

CONCRETE PILE AS NOTED
1/RB25G GALVANIZED REID BAR
CENTRAL

EXISTING POOL

PIERS TO FOUND AT BASE OF
ADJACENT EXCAVATIONS AND
INTO NATURAL MATERIAL AS
NOMINATED

COPYRIGHT - ALL RIGHTS RESERVED
Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.
DISCLAIMER

N12@900 Consulting Engineers accepts no responsibility for
the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900
Consulting Engineers.

DIMENSIONS.

Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

 

 

 

sqD SGD saD
SEP 18

 

 

S.G. DOCHERTY RPEQ No. 6213

0 200 1000
Litititi ti

SCALE 1:20 AT A3

 

 

 

 

 

 

1 PRELIMINARY 24.09.18] SGD

 

 

 

 

REV. | AMENDMENT DATE _ | INITIALS

 

PROPOSED POOL APRON
9 BERRIMA ROW
NOOSA HEADS

PROJECT

 

D. PANKOWSKI

CLIENT

 

ARCHITECT,

 

JFOOTING DETAILS

 

DRAWING TITLE

NTeSj0O)

CONSULTING ENGINEERS

 

ACN 129 181 086

ISUNSHINE COAST

PH 0410 599 211

EMAIL [email protected]

12 Sandy Cove Cre

COOLUM BEACH QLD 4573

 

 

18026 $1.03 1

PROJECT No. DWG No. REV.

 

 

 

Page 5

•


•


•



•




•



•



•




•

•


•




•




•

•




•


[OCR of page images]
 

COPYRIGHT - ALL RIGHTS RESERVED
Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.

CLASS 3 AND 4 TIMBERS CLEAR OF THE GROUND AND DISCLAIMER
EXPOSED TO THE WEATHER TO BE PRESERVATIVE N12@900 Consulting Engineers accepts no responsibility for

the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900

TREATMENT TO BE MIN. H5 Consulting Engineers.

 

POOL BARRIERS

 

* Minimum barrier height from finished ground
level to the top of the barrier is 1200mm.

TREATED TO MIN. LEVEL H3, WHERE THESE TIMBERS
ARE IN CONTACT WITH THE GROUND PRESERVATIVE

+ Maximum allowable gap from finished ground

 

level to the bottom of any barrier is 100mm.

* Gaps between vertical members with
horizontals a minimum of 900mm apart, must
not exceed 100mm.

EXISTING TIMBER

 

DIMENSIONS.
Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

 

 

 

 

SLEEPER RETAINING WALL SGD SGD SGD
+ Where the horizontals are less than 900mm Z DRAWN. DESIGNED CHECKED
apart, the gaps between verticals must not 4 SEP 18
exceed 10mm and the horizontals must have a Z APPROVED DATE
60-degree fillet attached. <
a S.G. DOCHERTY RPEQ No. 6213

* Climbable objects must be at least 900mm
away from the pool barrier on the outside and
300mm on the inside.

* No objects (decks, door sills, etc.) can be so
close as to reduce the minimum 1200mm fence
height.

+ If it is not possible to achieve a 900mm
nonclimbable zone on the outside, then the
fence height can be raised to 1800mm and a
900mm nonclimbable zone created at the top
on the inside, with no objects like decks below
the nonclimbable zone that would reduce the
1800mm height/drop from the top of the fence.

POOL BARRIER GATES

* pool gates must not open toward the pool area.

+ pool gates must be self-closing and latching
from all positions.

+ the bottom of any latch release mechanism on
the outside of the gate must be at least
1500mm above the ground and 1400mm

EXISTING SEWER
MANHOLE

EXISTING CONCRETE
MASONRY RETAINING
WALL

  

EXISTING PAVERS

  

EXISTING
CONCRETE

EXISTING BUILDING

0 1000 5000
[i Tit. Ti Ti]

SCALE 1:100 AT A3

 

 

 

 

 

 

1 PRELIMINARY 24.09.18] SGD

 

 

 

 

REV. | AMENDMENT DATE _ | INITIALS

 

PROPOSED POOL APRON
9 BERRIMA ROW
NOOSA HEADS

 

 

PROJECT

above the top of the highest lower horizontal

above t 9 D. PANKOWSKI
CLIENT

* pool gate hinges must be at least 900mm

apart or the lower hinge must have a non- ARCHITECT.

 

climbable (sixty degree) safety cap affixed to TRIMMER
prevent climbing. JOIST TO END IDECK FRAMING PLAN
AS DETAILED

Door and Windows
+ there is no direct access through a door from
the house to the pool area

Yo

 

 

* windows opening onto the pool area must not FACE MOUNT FJ1 AT FB3 EXTG CONG
open more than 100mm or must be security DRAWING TITLE
screened. MASONRY (]
RET. WAL
Signage (]
* a compliant CPR sign must be displayed either AZZ 7 ZIT bb

be attached to the barrier for the pool, or

displayed near the pool, so that the sign is

conspicuous and easily visible to anyone near
the pool.

POOL ENCLOSURE TO BE QBCC COMPLIANT,
REFER TO http://www.gbcc.qld.gov.au

FOR PARTICULAR DETAILS

 

 

FLOOR FRAMING PLAN
FOR GENERAL NOTES REFER DRAWING S0.01

MEMBER SCHEDULE

DENOTES APPROXIMATE
LOCATION OF EXISTING POST
FOOTINGS

bo] NIO@SOO

CONSULTING ENGINEERS

 

ACN 129 181 086

ISUNSHINE COAST

PH 0410 599 211

 

BEAMS © DENOTES 225 REINF. CONCRETE EMAIL [email protected]

_, PIER 12 Sandy Cove Cre

Fst 125x50 F14 HWD AT 450 CTRS COOLUM BEACH QLD 4573
TRhesssoe T2ax50 F14 HWD ALL FIXINGS AND BRACKETS TO

FBI... 175x75 F14 HWD BE HOT DIP GALVANIZED (HDG)

FBQvcssee 200x50 F14 HWD PROPRIETARY TIMBER

FB3....... 150x75 £14 HWD CONNECTORS TOBE STAINLESS [18026 S2.01 1

 

 

PROJECT No. DWG No. REV.

 

Page 6

 

 

 

 

{

FACEMOUNT AND \/
2/TYPE 17 14-10
SCREWS

 

 

 

 

 

 

 

JOIST HANGER C/W
4/TYPE 17 14-10 ——}
SCREWS TO EACH

 

 

MEMBER " —

SECTION f x \
110 AT A3

 

 

 

 

 

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

|
| DETAIL (1
110 AT A3 \sz.01 DETAIL (2
1:10 AT A3 \sz.o1 125x38 F14 HWD
TRIMMER TO JOISTS
2/TYPE 17 14-10
> SCREWS
ce _ 100x75 F14 HWD FENCE
< POST Tis
a © 5
S TIMBER PALINGS PER = s “i
° [7 CLIENT SPEC. FA 2 gi
0 1/M12 BOLT TYP. —4
RB25NG EXISTING
GALVANIZED REID [= CONCRETE
_ 75x38 F14 HWD RAILS: NUT AND WASHER oe MASONRY
TOP, MID & BOTTOM. TYP. " 3, RETAINING
LY CHECK TO POST Ves WALL
rl 150x90x8.0 UA 1/TRIPL GRIP
} 2/TRIPL GRIPS BRACKET [— C/W 3/2.8¢ f
AT FENCE POST TYP. REINF. HD NAILS
i TYP
|
INCOMPRESSIBLE
| PACKER AS
| REQUIRED SECTION (B
1:10 AT A3 \sz.0o1
EXISTING
L.____ CONCRETE POOL
SHELL

 

 

 

 

 

 

 

 

 

2/M12 BOLTS
TO FB1

 

1/M12 BOLT TO
FJ1

ALL FIXINGS AND BRACKETS TO
BE HOT DIP GALVANIZED (HDG)
PROPRIETARY TIMBER
CONNECTORS TO BE STAINLESS

 

 

 

 

 

 

 

 

CONCRETE PIER
AS NOTED

SECTION OO
110 AT AS

 

Q

DETAIL Gs)
1:10 AT A3 \s2or/

JOIST HANGER
8/2.80 REINF

HD NAILS PER
LEG

BATTENS TO

   
 
  
 

DETAIL

1:10 AT A3

75x38 F14 HWD
BATTEN TO DECKING
W/TYPE 17 14-10

DECKING AS
NOTED

DECKING PER
CLIENT SPEC.

\s20)

 

 

 

 

 

 

 

SCREW ATSO0CTRS |
MIN. 38 EMBEDMENT DECKING PER
STAGGER [CLIENT SPEC.
u KK 1
—_ =
F/I ® ° FJ

 

50 SQ. F14 HWD
BATTEN 1/TYPE 17
14-10 SCREW AT
500 CTRS MIN. 38
EMBEDMENT
STAGGER

REMOVABLE HATCH

BATTEN 1/TYPE 17

EX. DECKING

50 SQ. F14 HWD

 

14-10 SCREW AT
300 CTRS MIN. 38
EMBEDMENT

   
  

 

 

 

 

 

SECTION f \
110 AT A3

SECTION f Z \
110 AT A3

COPYRIGHT - ALL RIGHTS RESERVED

DISCLAIMER

 

Consulting Engineers.
DIMENSIONS.

Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.

N12@900 Consulting Engineers accepts no responsibility for
the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900

Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

sqD

DRAWN

SGD

DESIGNED

 

saD

CHECKED.

 

APPROVED.

 

SEP 18

DATE

 

S.G. DOCHERTY RPEQ No. 6213

 

 

 

 

 

 

 

 

0 100 500
Li Ti Titi Ti)
SCALE 1:10 AT A3

T_| PRELIMINARY 7.0518} SCO

 

 

 

9 BERRIMA ROW
NOOSA HEADS

PROJECT

PROPOSED POOL APRON

 

D. PANKOWSKI

CLIENT

 

ARCHITECT,

 

 

DRAWING TITLE

JDECK FRAMING DETAILS

NTeSj0O)

CONSULTING ENGINEERS

 

ACN 129 181 086

SUNSHINE COAST
PH 0410 599 211

12 Sandy Cove Cre

EMAIL [email protected]

COOLUM BEACH QLD 4573

 

18026

PROJECT No.

 

S2.02 1

DWG No.

 

 

 

Used in these records

About this file

File size
990 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

N12 9 berrima_180928.pdf · 990 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.