Attached to the e-mail GIA (pool deck) - 51901.4210.01.
FOOTING NOTES CONCRETE: N32, REINFORCEMENT: AS NOTED CONCRETE WORK SHALL BE IN ACCORDANCE WITH A.S. 3600. AT THE TIME OF INSPECTION, REINF'T SHALL BE IN PLACE WITH PROVISION FOR MIN. 60mm COVER FOR FOOTINGS. REINFORCEMENT LAPS N12... 500 N16... 650 N20... 800 MESH ..... 2 CROSS WIRES + 25MM EXISTING TIMBER SLEEPER RETAINING WALL EXISTING SEWER \ MANHOLE \ . \ \ CONCRETE PIERS AS =O DETAILED ye \ EXISTING CONCRETE Uy MASONRY RETAINING 1 WALL EXISTING CONCRETE MASONRY RETAINING WALL SLAB & FOOTING PLAN FOR GENERAL NOTES REFER DRAWING S0.01 DENOTES APPROXIMATE LOCATION OF EXISTING POST FOOTINGS © DENOTES 225@ REINF. CONCRETE PIER EXPOSURE CLASSIFICATION TO AS 3600 IS - B1 2 a 2 a 4 a 7 a 2 a 2 a <O EXISTING PAVERS EXISTING BUILDING EXISTING CONCRETE POOL / eo COPYRIGHT - ALL RIGHTS RESERVED Copying or reproducing the whole or part of this document in any form without the written permission of N12@900 Consulting Engineers constitutes an infringement of copyright. DISCLAIMER N12@900 Consulting Engineers accepts no responsibility for the accuracy or for any consequence resulting from the use or alteration of this drawing in electronic form. Drawings in electronic form should be checked for accuracy against the equivalent revision hard copy issued by N12@900 Consulting Engineers. DIMENSIONS. Prior to commencing construction verify all dimensions against Architect's, other Consultant’s and Sub-Contractor’s drawings. Dimensions are not to be scaled or read electronically from this drawing. Setout dimensions, unless specifically shown, are to be obtained from the Architect's or other Consultant's drawings. sqD SGD saD DRAWN DESIGNED CHECKED. MAY 18 APPROVED. DATE S.G. DOCHERTY RPEQ No. 6213 0 1000 5000 Citi ti Ti Ti) SCALE 1:100 AT A3 1 PRELIMINARY 24.09.18] SGD REV. | AMENDMENT DATE _ | INITIALS PROPOSED POOL APRON 9 BERRIMA ROW NOOSA HEADS PROJECT D. PANKOWSKI CLIENT ARCHITECT, JFOOTING PLAN DRAWING TITLE CONSULTING ENGINEERS ACN 129 181 086 ISUNSHINE COAST PH 0410 599 211 EMAIL [email protected] 12 Sandy Cove Cre COOLUM BEACH QLD 4573 18026 $1.02 1 PROJECT No. DWG No. REV.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
N12 9 berrima_180928.pdfRelated documentApplication case desk ↗
About this file
- File size
- 990 KB (small file)
- File type
No other editions are linked here.