Skip to the record
The gold standard in government transparency.

Council archive · source document

N12 9 berrima_180928 · 51901.4210.01

Attached to the e-mail GIA (pool deck) - 51901.4210.01.

of 6

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

 

 

FOOTING NOTES
CONCRETE: N32, REINFORCEMENT: AS NOTED

CONCRETE WORK SHALL BE IN
ACCORDANCE WITH A.S. 3600.

AT THE TIME OF INSPECTION, REINF'T
SHALL BE IN PLACE WITH PROVISION
FOR MIN. 60mm COVER FOR FOOTINGS.

REINFORCEMENT LAPS

N12... 500
N16... 650
N20... 800

MESH ..... 2 CROSS WIRES + 25MM

EXISTING TIMBER
SLEEPER RETAINING WALL

EXISTING SEWER \
MANHOLE \

. \

\

CONCRETE PIERS AS =O

DETAILED ye

\

EXISTING CONCRETE Uy
MASONRY RETAINING 1
WALL

EXISTING CONCRETE
MASONRY RETAINING
WALL

 

SLAB & FOOTING PLAN
FOR GENERAL NOTES REFER DRAWING S0.01

DENOTES APPROXIMATE
LOCATION OF EXISTING POST
FOOTINGS

© DENOTES 225@ REINF. CONCRETE

PIER

EXPOSURE CLASSIFICATION
TO AS 3600 IS - B1

2 a
2 a
4 a
7 a
2 a
2 a
<O EXISTING PAVERS
EXISTING BUILDING
EXISTING
CONCRETE
POOL
/
eo

COPYRIGHT - ALL RIGHTS RESERVED
Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.
DISCLAIMER

N12@900 Consulting Engineers accepts no responsibility for
the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900
Consulting Engineers.

DIMENSIONS.

Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

 

 

 

sqD SGD saD
DRAWN DESIGNED CHECKED.
MAY 18
APPROVED. DATE

 

 

S.G. DOCHERTY RPEQ No. 6213

0 1000 5000
Citi ti Ti Ti)

SCALE 1:100 AT A3

 

 

 

 

 

 

1 PRELIMINARY 24.09.18] SGD

 

 

 

 

REV. | AMENDMENT DATE _ | INITIALS

PROPOSED POOL APRON
9 BERRIMA ROW
NOOSA HEADS

 

PROJECT

D. PANKOWSKI

CLIENT

 

 

ARCHITECT,

JFOOTING PLAN

 

 

 

DRAWING TITLE

CONSULTING ENGINEERS

 

ACN 129 181 086

ISUNSHINE COAST

PH 0410 599 211

EMAIL [email protected]

12 Sandy Cove Cre

COOLUM BEACH QLD 4573

 

18026 $1.02 1

 

 

 

PROJECT No. DWG No. REV.

Used in these records

About this file

File size
990 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

N12 9 berrima_180928.pdf · 990 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.