COPYRIGHT - ALL RIGHTS RESERVED
Copying or reproducing the whole or part of this document in any
form without the written permission of N12@900
Consulting Engineers constitutes an infringement of copyright.

CLASS 3 AND 4 TIMBERS CLEAR OF THE GROUND AND DISCLAIMER
EXPOSED TO THE WEATHER TO BE PRESERVATIVE N12@900 Consulting Engineers accepts no responsibility for

the accuracy or for any consequence resulting from the use
or alteration of this drawing in electronic form.

Drawings in electronic form should be checked for accuracy against
the equivalent revision hard copy issued by N12@900

TREATMENT TO BE MIN. H5 Consulting Engineers.

 

POOL BARRIERS

 

* Minimum barrier height from finished ground
level to the top of the barrier is 1200mm.

TREATED TO MIN. LEVEL H3, WHERE THESE TIMBERS
ARE IN CONTACT WITH THE GROUND PRESERVATIVE

+ Maximum allowable gap from finished ground

 

level to the bottom of any barrier is 100mm.

* Gaps between vertical members with
horizontals a minimum of 900mm apart, must
not exceed 100mm.

EXISTING TIMBER

 

DIMENSIONS.
Prior to commencing construction verify all dimensions against
Architect's, other Consultant’s and Sub-Contractor’s drawings.
Dimensions are not to be scaled or read electronically from this
drawing. Setout dimensions, unless specifically shown, are to be
obtained from the Architect's or other Consultant's drawings.

 

 

 

 

 

SLEEPER RETAINING WALL SGD SGD SGD
+ Where the horizontals are less than 900mm Z DRAWN. DESIGNED CHECKED
apart, the gaps between verticals must not 4 SEP 18
exceed 10mm and the horizontals must have a Z APPROVED DATE
60-degree fillet attached. <
a S.G. DOCHERTY RPEQ No. 6213

* Climbable objects must be at least 900mm
away from the pool barrier on the outside and
300mm on the inside.

* No objects (decks, door sills, etc.) can be so
close as to reduce the minimum 1200mm fence
height.

+ If it is not possible to achieve a 900mm
nonclimbable zone on the outside, then the
fence height can be raised to 1800mm and a
900mm nonclimbable zone created at the top
on the inside, with no objects like decks below
the nonclimbable zone that would reduce the
1800mm height/drop from the top of the fence.

POOL BARRIER GATES

* pool gates must not open toward the pool area.

+ pool gates must be self-closing and latching
from all positions.

+ the bottom of any latch release mechanism on
the outside of the gate must be at least
1500mm above the ground and 1400mm

EXISTING SEWER
MANHOLE

EXISTING CONCRETE
MASONRY RETAINING
WALL

  

EXISTING PAVERS

  

EXISTING
CONCRETE

EXISTING BUILDING

0 1000 5000
[i Tit. Ti Ti]

SCALE 1:100 AT A3

 

 

 

 

 

 

1 PRELIMINARY 24.09.18] SGD

 

 

 

 

REV. | AMENDMENT DATE _ | INITIALS

 

PROPOSED POOL APRON
9 BERRIMA ROW
NOOSA HEADS

 

 

PROJECT

above the top of the highest lower horizontal

above t 9 D. PANKOWSKI
CLIENT

* pool gate hinges must be at least 900mm

apart or the lower hinge must have a non- ARCHITECT.

 

climbable (sixty degree) safety cap affixed to TRIMMER
prevent climbing. JOIST TO END IDECK FRAMING PLAN
AS DETAILED

Door and Windows
+ there is no direct access through a door from
the house to the pool area

Yo

 

 

* windows opening onto the pool area must not FACE MOUNT FJ1 AT FB3 EXTG CONG
open more than 100mm or must be security DRAWING TITLE
screened. MASONRY (]
RET. WAL
Signage (]
* a compliant CPR sign must be displayed either AZZ 7 ZIT bb

be attached to the barrier for the pool, or

displayed near the pool, so that the sign is

conspicuous and easily visible to anyone near
the pool.

POOL ENCLOSURE TO BE QBCC COMPLIANT,
REFER TO http://www.gbcc.qld.gov.au

FOR PARTICULAR DETAILS

 

 

FLOOR FRAMING PLAN
FOR GENERAL NOTES REFER DRAWING S0.01

MEMBER SCHEDULE

DENOTES APPROXIMATE
LOCATION OF EXISTING POST
FOOTINGS

bo] NIO@SOO

CONSULTING ENGINEERS

 

ACN 129 181 086

ISUNSHINE COAST

PH 0410 599 211

 

BEAMS © DENOTES 225 REINF. CONCRETE EMAIL [email protected]

_, PIER 12 Sandy Cove Cre

Fst 125x50 F14 HWD AT 450 CTRS COOLUM BEACH QLD 4573
TRhesssoe T2ax50 F14 HWD ALL FIXINGS AND BRACKETS TO

FBI... 175x75 F14 HWD BE HOT DIP GALVANIZED (HDG)

FBQvcssee 200x50 F14 HWD PROPRIETARY TIMBER

FB3....... 150x75 £14 HWD CONNECTORS TOBE STAINLESS [18026 S2.01 1

 

 

PROJECT No. DWG No. REV.

 

Used in these records

About this file

File size
990 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

N12 9 berrima_180928.pdf · 990 KB (small file)