Original source · versioned page text
Electrical AC1286 Preliminary Design Sub 2 Pearsons Road, Cooroy 4563 [20-08-2021]
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
0.14 Lux
0.14 Lux
13L CATEGORY PR5
0.14 Lux
P2251872
BLUE WREN PLACE
9L P2251871
17L P2251873
BLUE W P Category Lighting - AS/NZS 1158.3.1:2005
REN PL ******************************************
ACE
19L P2251874
0.14 Lux Auspower Connect
----------------
0.14 Lux I-table Filename: C:\Users\Auspower\Desktop\Modular LED 15W 4K 17032
0.14 Lux
6PHM.CIE
Job Name: AC1286 - 2 PEARSONS ROAD COOROY
20L P2251875
Luminaire Description: Modular LED 15W 4K 170326PHM use 1899lms
Initial Lamp Flux: 1899 lms
Maintenance Factor: 0.75
Stores Code:
Upcast Angle: 0 degrees
Arrangement: Single Side
Offset Distance: 1/4 Road Reserve
Upward Waste Light Ratio: 2.8 %
0.14 Lux
Light Source: LED - Light Emitting Diode
Luminaire Classification: Not specified
Lighting Category: P4 (Local Area Roads - Tables 2.1 & 2.6)
Illuminance Criteria: Average Illuminance (Eav) >= 0.85 lx
(Maintained values) Minimum Illuminance (Eph) >= 0.14 lx
ISOLUX CONTOUR Illuminance Uniformity (Up) <= 10
10 0 10 20 30 40 50 METRES
Calculation Grid: 20 x 11 points - Figure 3.7 of AS/NZS 1158.2
Mounting Maximum Spacing for different
SCALE 1:500 AT A1 Height Road Reserve Widths
15.0
+---------------------+
5.1 I 61.0 I
+---------------------+
Value/s in above table are all in metres.
The table contains maximum spacings which, for the specified luminaire
and lamp combination, provide compliance with the light technical
parameters (LTPs) of Table 2.6 of AS/NZS 1158.3.1:2005.
Light Technical Parameters at Maximum Spacing
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
Mounting Road Maximum Eav Eph Up Emax
Height Reserve Spacing (Emax/Eav)
(m) (m) (m) (Ix) (Ix) (Ix)
5.1 15.0 61.0 1.12 0.14 5 6.04
---------------------------------------------------------------------------
PlePcat - Vers 3.10 (Built: 10/ 4/13)
Run: 28/06/2021 at 14:44:44
ISSUE DESCRIPTION DATE AUSPOWER CONNECT IS THE FIRST POINT OF DEVELOPER DETAILS ALIGNMENTS WORKS COORDINATOR - APPROVED: SUBDIVISION AUSPOWER CONNECT
AC1286
P PRELIMINARY DESIGN 20/08/2021 CONTACT FOR CONSTRUCTION ENQUIRIES. Auspower Connect Pty Ltd Ventralia Pty Ltd ENERGEX OH 3.0m PARENT PROJECT NO. - RECONFIGURE 1 LOT INTO 16 LOTS PROJECT NO.
Darren Matthews ENERGEX UG 0 - 0.9m WORK REQUEST NO. - RAL 20/0021 SCALE: 1:500
PO Box 531
0499 339 155 STREETLIGHTS 0.7m I.O.K LOTS 1-16 ENERGEX PROJECT NO.
Buddina, QLD 4575 ELECTRICAL RETICULATION
[email protected] NBN REFER DBYD
Mob 0419 707 166 INSTALL 5 LED 15W AERO 4K STREET LIGHTS
[email protected]
PROJECT MANAGER DETAILS GAS - CANCELLING LOTS 3 on RP113733 APPROVED DATE: N/A ENGINEERING INFORMATION S4400244
Ventralia Pty Ltd HP GAS - D.A RAL 20/0021 CHECKED: J McKenna
ABN 74 166 366 883
Darren Matthews WATER REFER DBYD LOCAL AUTHORITY Noosa Council DESIGNER: I Lubacheski
This drawing is the property of Auspower Connect Pty Ltd and 2 PEARSONS ROAD
0499 339 155 STORMWATER REFER DBYD UBD REF Map 5 A-20 PHONE: 0419 707 166
must not be used, retained or copied without written permission
COOROY 4563 ISSUE NO. P SHEET 5 OF 5 A1
[email protected] SEWER REFER DBYD PEGGED On Request ISSUE DATE: 20/08/2021