44. A Registered Professional Engineer of Queensland shall certify engineering drawings
and specifications for all engineering works, which shall be submitted in conjunction with
an application for a Development Permit for Operational Works.
Building Services
45. A verification survey of the building is to be carried out by a Licensed Surveyor and a
certificate lodged with Council at completion of the work confirming compliance with the
maximum building height above natural surface, required by the provisions of the
Planning Scheme.
Environmental Health
46. The developer must provide a suitably screened imperviously paved area large enough
for all refuse and recycling containers. A wash down area is required with a cold-water
tap, hose and drain outlet connected to sewer. The drain outlet is to be designed to
prevent stormwater entry to the sewerage system.
47. Swimming pool or spa pumps are to be contained in an acoustically treated enclosure or
located in a manner which prevents a noise nuisance beyond the subject land in
accordance with the nuisance provisions of the Environmental Protection Regulation
1998. On the spot fines apply for such offences.
48. All lift plant including motors, shall be situated within the building or suitably provided
with noise reduction measures and located as to prevent a noise nuisance beyond the
subject land in accordance with the nuisance provisions of the Environmental Protection
Regulation 1998. On the spot fines apply for such offences.
49. Noise emission from air conditioning equipment shall comply with the following
requirements:
49.1 The equipment shall be installed and located in a manner which prevents noise
nuisance beyond the subject land in accordance with the nuisance provisions of
the Environmental Protection Regulation 1998 and Council’s Local Law No. 12 -
Control of Nuisances. Infringement Notices (on-the-spot fines) may apply for
offences.
49.2 Submission of written certification from a suitably qualified person confirming that
the noise levels comply when measured at the nearest residential boundary. This
is required immediately after installation of the equipment and prior to any
occupation of the building, and in a format approved by Council.
49.3 A person must not use equipment on any day if it makes or causes noise to be
made –
49.3.1 Before 7am or after 10pm: More than the lower of either –
40 d(B)A
3 d(B)A above the background noise level
49.3.2 From 7am to 7pm: More than the lower of either –
50 d(B)A
5 d(B)A above the background noise level
49.3.3 From 7pm to 10pm: More than 3 d(B)A above the background noise
level.
5 REFERRAL AGENCY CONDITIONS
Not Applicable
Page 7 of 11
Document Set ID: 20351003
Version: 3, Version Date: 07/07/2017 Print Date: 26 July 2017, 8:39 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 1a - permissible change approval.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.