Manufacturing - Floor Manufacturing - Ceiling General Notes & Disclaimers
Manufacturing - Electrical Equipment • Wall/Ceiling/Roof frames built to Ausco
Tag Type Frame Crs. Pan Material Insulation Tag Description Phases Qty. Installed Frame Backbone framing design standards.
FL01 Particleboard, 22mm, F11 flooring grade, LC150 joists 400 0.35mm Galv Steel Pan R1.5 Glass Wool EQ01 PE Cell 3 By Ausco Tag Frame Crs. Lining Insulation • Building chassis designed to Ausco
FL02 Decking, Modwood 22mm 480 - - EQ02 Smoke Alarm 240V 1 By Ausco CL01 Engineered steel frame, 400 Versilux, 6mm, H-mould (White), to - Standard Chassis drawings.
75mm "Lipped C" section eaves & verandah • All work must be done in accordance with
CL02 Engineered steel frame, 400 Plasterboard, 10mm, TSF (White) R4.0 Glass the relevant Australian/New Zealand
75mm "Lipped C" section Wool Bats
Manufacturing - Walls Manufacturing - Electrical Fixtures Standard(s) and the National Construction
Code.
Frame Tag Description Qty. Installed • Furniture, plumbing, & electrical
Tag Frame Crs. Cladding Lining Insulation EE01 Draw wire, with plate 31 By Ausco
representations are indicative. Appearance
WL01 Engineered steel frame, 75mm, 600 - Plasterboard, 10mm, TSF - EE02 GPO, 2 gang, 10A, single pole 32 By Ausco Manufacturing - Roof
may vary depending on supplier.
"Lipped C" section (Blanc) EE03 Isolator Switch, 20A, single pole WP 9 By Ausco Frame • Loose items to be packed for transport.
WL02 Engineered steel frame, 75mm, 400 Scyon Matrix Panel (Deep Ocean & Plasterboard, 10mm, TSF R2.0 glasswool EE05 Switch, 2 gang, 1 way, single pole 4 By Ausco Tag Frame Crs. Cladding Lining Insulation
"Lipped C" section Paperbark, refer elvations, express joint (Blanc) batts EE06 Floor Box, flush mounted, -'Commander F4BP' 2 x GPO 2 gang 2 By Ausco
• Site, stairs, ramp and building skirting
painted black) RF01 Engineered steel 1100 Custom Orb (Deep - R1.8 Glass Wool indicative only. Size, fall and location to suit
10A single pole & 4 x Draw wire with plate
frame purlins, Ocean) Foil
WL03 Engineered steel frame, 75mm, 400 3.6mm Rough Ply Plasterboard, 10mm, TSF R2.0 glasswool EE09 General purpose outlet, weatherproof, 10A, single pole 6 By Ausco 75mm, "Lipped C"
site conditions. Constructed to comply with
"Lipped C" section (Blanc), one side only batts EE10 Switch, 2 gang, 1 way, single pole - Ceiling Fan 4 By Ausco section AS1428.1.
WL03 Engineered steel frame, 75mm, 400 Scyon Matrix Panel (Deep Ocean & Plasterboard, 10mm, TSF R2.0 glasswool Manufactured to Wind Speed: B190
"Lipped C" section Paperbark, refer elvations, express joint (Blanc) batts
painted black)
Manufactured in: MQB
Manufacturing - Lighting Fixtures Manufacturing - Trims (General) Manufacturing - Trims (Gutters) Intended Location: Noosaville, QLD
Tag Description Lamps Qty. Installed Description Description
CCS pre-finished barge (Manor Red) CCS prefinished gutter (Manor Red) Client Approval
Manufacturing_Doors LT01 Light, Emergency Exit compliant to AS2293.1, ceiling 1 6 By Ausco
mounted Client: Good Shepard Lutheran College
Size Finish
LT02 Vandal resistant light, 18W, clear 1 13 By Ausco Manufacturing - Plumbing Fixtures
Frame Frame
LT03 Fluorescent batten, 2x36W, diffused 2 38 By Ausco Tag Description Qty. Installed Approved by:
Tag Qty. Style/Type Leaf 1 Leaf 2 H H (R) W (R) Head Glazing Type Finish Leaf Finish Accessories
LT04 LED 3W Emergency Surface Mount 1 By Ausco
D02 6 Swing Door 920 0 2040 2085 950 2040 Clear Aluminium Clear Timber SC Half Glazed, lever escape set 3 By Ausco Company:
w/ Anodised w/ (Deep (Satin Chrome), hold open door PL01 CCS Slotted Gutter (Manor red) 1 By Ausco
Aluminium Black trims Ocean) closer
trims
Manufacturing - Mechanical PL02 100x75mm CCS Straight Downpipe (Deep Ocean) 5 By Ausco Date (dd-mm-yyyy):
PL03 100x75mm Offset CCS Down Pipe(Deep Ocean) 7 By Ausco
Tag Description Qty. Installed Signature:
ME01 AC, Split system, indoor unit, 7.1kW pipework concealed in wall 5 By Ausco
Manufacturing_Windows ME02 AC, Split system, indoor unit, 5.0kW pipework concealed in wall 4 By Ausco Manufacturing - Structural Framing
Size Finish ME03 Split System Reverse Cycle, Outdoor unit, packed and installed on 9 By Ausco Tag Qty. Comments Description
Frame Frame site Drawings - Architectural
B 2 Ausco Type 'B' wall bracing
Tag Qty. Style/Type H H (R) W W (R) Head Glazing Type Finish Accessories ME04 Ceiling fan, 1400mm 15 By Ausco Sheet Content Rev
B 19 Type B Wall Brace Ausco Type 'B' wall bracing
W01 15 Half Slider Window 1075 1080 1800 1810 2275 Grey Aluminium Clear Fibreglass Mesh Aluminium Flyscreen
Anodised (Black) BF01 3 Subframe black Perimeter, 150mm PFC, 12,000 x 3,450mm A-000 Schedules - Building Shell I
A-001 Site Plan I
W02 4 Half Slider Window 1075 1080 1155 1165 2275 Grey Aluminium Clear Fibreglass Mesh Aluminium Flyscreen Manufacturing - Complexing
Anodised (Black) A-100 Ground Floor Plan I
W4 8 Window w/Side Louvres 462 467 1800 1810 612 Grey Aluminium Clear Fibreglass Mesh Aluminium Flyscreen Rear Wall external - Flexible Gap sealant with Down pipe over By Ausco A-101 Roof Plan I
Anodised (Black)
A-200 Elevations I
Front wall external - Flexible Gap sealant & painted finish By Ausco A-300 Ground Floor RCP I
Internal walls - Fully flushed and painted finish By Ausco A-500 Section & Details I
Manufacturing - Rooms
Internal Ceiling - Fully flushed and painted finish By Ausco
Name Area Perim. Floor Covering Skirting Cornice
Breakout Room 1 Not Placed Not Placed Carpet Tiles Aluminium skirt 100mm (Clear Anodised) 55mm Set plaster cornice External Soffit/Eave - 50mm 'T' mold 'White'(8 x 600L & 4 x 2400L) By Ausco
Breakout Room 2 Not Placed Not Placed Carpet Tiles Aluminium skirt 100mm (Clear Anodised) 55mm Set plaster cornice
Staff Room Not Placed Not Placed Carpet Tiles Aluminium skirt 100mm (Clear Anodised) 55mm Set plaster cornice External Barge - 80x40 CCS angle under gutter 'Manor red'(8 x 600L) By Ausco
Breakout Room 1 39.61 m² 26.32 m
No Floor coverings. By Others
Breakout Room 2 23.25 m² 19.30 m
Breakout Room 3 47.00 m² 28.82 m Carpet Tiles Aluminium skirt 100mm (Clear Anodised) 55mm Set plaster cornice
Classroom 1 63.37 m² 32.30 m Carpet Tiles Aluminium skirt 100mm (Clear Anodised) 55mm Set plaster cornice
Classroom 2 62.90 m² 32.20 m Carpet Tiles Aluminium skirt 100mm (Clear Anodised) 55mm Set plaster cornice
I Moved ramp, Added deck, stairs & windows 15.07.2020 CB
Deck 15.82 m² 16.11 m Modwood NA NA H Moved Staff Room 30.06.2020 CB
Deck 65.31 m² 59.54 m Modwood NA NA G Bigger Breakout Room 2 29.06.2020 CB
Staff Room 30.38 m² 25.30 m F Adjusted Building Location and added RL's, Moved Stairs and 26.07.2019 JP
Ramp
E Resizing of Buildings and Layouts. Relocated Office Moved 19.07.2019 JP
D For Client Approval 31.08.2018 IC
Iss. Description Date By
FOR APPROVAL
COPYRIGHT AUSCO MODULAR PTY LTD. THIS DOCUMENT MAY NOT BE
REPRODUCED OR HAVE ITS CONTENTS DIVULGED WITHOUT WRITTEN
AUTHORITY.
Title
Schedules - Building
Shell (MQB)
Project
30.85x12m Learning Centre-
SG (B190)
Client
Good Shepard Lutheran
College
Drawn By Drawn Date Scale
APPROVED PLANS
-
IC MAR 18 1:1 A2
MCU20/0072 Checked By Check Date
DIMENSIONS ARE IN MM
NOOSA COUNCIL AAD MAR 18
15/07/2020 7:00:51 PM
DO NOT SCALE
19 AUGUST 2021 Project No. Order No.
- 0240100047 -
Drawing No. Sheet Issue
- A-000 I
Designed by: Brisbane
Document Set ID: 21594200
21213117
21260700
Version: 1, Version Date: 25/08/2021
05/08/2020
14/10/2020
See the original