130814 Permissible Change Request Final · MCU14/0073
Attached to the e-mail OPW13/1038.01 Request to Change to existing approval.
EDGE OF BUILDING (REFER TO
ARCHITECTURAL DRAWINGS)
5m 4.7m 6.0m VARIES 6.0m 5.4m
CONCRETE PATH 10 BICYCLE SPACES DRIVEWAY (CONCRETE) LANDSCAPING DRIVEWAY (CONCRETE) PARKING (CONCRETE)
GARDEN 600 x 600 SW
EXISTING TABLE DRAIN
0.2m
PIT WITH RAISED GRATE;
RP BDY
OFFICE FFL 95.85 FFL 95.80 REFER TO DWG R07 FOR
1.0% DETAILS
1.0%
LAKE MACDONALD DRIVE
FOR LANDSCAPING DETAILS SCRC BARRIER KERB B4
DRAIN PIPES OUTLET
REFER TO LANDSCAPING TYPE
TO STORMWATER PIT EXISTING TELSTRA
ECOSOL 100 GPT OR DRAWINGS
CONDUITS EXISTING WATER MAIN
APPROVED EQUIVALENT
SECTION A-A
R05 SCALE 1:200
EXISTING DOWN PIPE CUT AND CONNECT
EXISTING BUILDING EXISTING RCP TO
2.0m WIDE;250DEEP PROPOSED 1050 MH
GRASS SWALE PROPOSED
2m 1050 MH
INTERNAL DRIVEWAYS
EXISTING CONCRETE FLOW PIPE
IL 95.1 IL 94.78
IL 94.44 150 THICK N32 CONCRETE
SL 92 TOP 50 COVER
OUTLET TO
UNDERGROUND 100 THICK GRAVEL MIN CBR 15
WATER TANK CREEK
SECTION B-B
R06 SCALE 1:200 50 50
PERMANENT CAPPING
MESH
BYPASS
16mm DOWEL
400 LONG @ 400crs
PROPERTY ALIGNMENT
DANLEY RIPA STRIP JOINT (GREY)
CONCRETE 1.0m 10.41m
BENCHING (WEIR) DJ
EXISTING EDGE OF
BITUMEN
FLOW TO RAINWATER TANK 5.0%
PAVEMENT DETAILS
LAKE MACDONALD 1:8
DRIVE FINAL PAVEMENT DEPTH TO BE DETERMINED FOLLOWING SOIL TESTS BY GEOTECHNICAL ENGINEER.
SLAB CONSTRUCTION AND JOINTING TO BE IN ACCORDANCE WITH THE "GUIDE TO RESIDENTIAL
SL82 REINFORCING STREETS & PATHS" - CEMENT & CONCRETE ASSOCIATION OF AUSTRALIA.
FABRIC 50mm TOP AND CONCRETE PAVEMENT HAS BEEN DESIGNED FOR RESIDENTIAL & SERVICE TRAFFIC LOADINGS ONLY.
EDGE COVER. PAVEMENT DEPTHS MAY VARIED BY THE SUPERINTENDENT FOLLOWING SUBGRADE TESTING.
OVERFLOW PIPE
TO SERVICES 600mm CONDUIT LOCATIONS IF REQUIRED.
NOTIFY ALL RELEVANT AUTHORITIES PRIOR TO COMMENCEMENT OF WORK WITHIN EXISTING ROAD
FLOW RESERVE.
DRIVEWAY ENTRANCE - CROSSOVER DETAIL THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING SERVICES WITHIN THE SITE PRIOR
TO COMMENCING WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING
SERVICES WHETHER SHOWN ON THE DRAWINGS OR NOT.
PLAN ALL WORK SHALL CONFORM WITH THE RELEVANT LOCAL AUTHORITY'S SPECIFICATIONS AN
REQUIREMENTS
CONCRETE 110
BENCHING
LOW FLOW
BYPASS
COMPACTION STANDARDS
(WEIR) 40
ROADWORKS TO 300mm BELOW SUBGRADE 95% STANDARD
ROADWORKS WITHIN 300mm OF SUBGRADE 100% STANDARD
SUB BASE GRAVEL 100% STANDARD
150
R20 BASE GRAVEL 100% STANDARD
250mm
150 CONCRETE TYPE
FLOW
DRIVEWAYS PAVEMENTS N32
B4 BARRIER KERB
NTS
LOW FLOW BYPASS (TANK OVERFLOW)
NTS
CLIENT: JOB NUMBER
REV DATE DESCRIPTION BY CHKD SCALE APPROVED 1014
PROJECT:
DATUM
DESIGN
0 2 4 6 8 10m
................. SHEET: 9 OF 9
DRAWING NUMBER REV
Director: TONY SHELLEY DRAWING TITLE:
DRAWN SCALE 1:200 A3 (RPEQ 7736)
DESIGN CHECK TS
DRAWING STATUS
07 54534494 R09
This drawing is not to be copied or amended without written permission from [email protected] www.barlowshelley.com.au
DATE Barlow Shelley Consulting Engineers FOR APPROVAL PO Box 432 Buderim 4556 ABN 42 135 788 813
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
130814 Permissible Change Request Final.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.