Original source · versioned page text
6.5.22 - GCCC Flood Guideline
Shelter-in-place Small-scale developments proposing Reconfiguring a lot
only, must:
Shelter-in-place is defined as finding a safe location indoors,
seeking immediate shelter and staying there during a flood • propose appropriate wording to establish a covenant
emergency event until the threat is removed; rather than over the land that requires any future built form, to
evacuating the area to an alternative safe refuge. incorporate a shelter area above PMF, in accordance with
the shelter-in-place requirements
Interim framework • have the covenant registered on the property’s rates
notice.
As a minimum, the shelter-in-place component of the
development must:
Probable maximum flood levels
• be located above Probable Maximum Flood (PMF) and
Applicants who wish to know the PMF level for their property
provide a safe habitable space during an event
can forward an email request to
• be a minimum of 9m2 based on a single bedroom
[email protected]
occupancy, with an addition of 4m2 for each additional
bedroom
• contain toilet and shower facilities
• have unobstructed egress options for emergency
evacuation (balcony or deck evacuation options) For more information
• have a dedicated storage cupboard to store the necessary
For planning related matters, please contact our Planning
items as advised by emergency services goldcoast.qld.gov.
Enquiries Centre on:
au/council/be-prepared-462.html
• comply with the automatic fire detection and warning City of Gold Coast
requirements of the Building Code of Australia for its normal P 07 5582 8708
use E [email protected]
• be engineered to withstand the flood actions (forces)
generated by the PMF event.
See the original