Council archive · source document
01072015144724 · MCU10/2065
Attached to the e-mail MCU10/2065.01 Request to Extend the Development Approval 17 Grant St Noosa Heads.
MCU10/2065 — CIVIL ENGINEERING Vehicle Access 14. 15. 16. 417. A vehicular access driveway to serve the development must be constructed from the Grant Street frontage of the site with a maximum width of 4.5m at the property boundary. The driveway must be designed and consiructed to Council’ 's design standards and to grades that prevent vehicles from scraping and/or bottoming whilst also allowing ~ pedestrians movements along the footpath without any step or level difference. Should any driveways be constructed to grades that do not comply with AS/NZS 2890.1+-2004, Council will require that the driveway be removed and reconstructed to levels that do comply. Please note, a step between the driveway and the footpath must be avoided, as it is preferred to have the footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall: To ensure pedestrian safety between vehicles exiting the site and pedestrians on the’ footpath, the driveway and any associated fencing or vegetation near the driveway must comply with the minimum sight line requirements as defined in AS 2890.1, section 3.2.4. The applicant must demonstrate compliance by illustrating these sight lines on the plans submitted for both Operational Works approval and Building Works © approval. All vehicles must enter and leave the site in a forward direction. Car Parking 18. 19. 20. Carparking must be provided within the site generaily as shown on drawing number A- 03 dated 14 September 2010 by EPS Design, except as modified herein. The carparking area must be designed to comply with the provisions of AS/NZS 2890.1-2004 for user class 1A with allowance for vehicles to enter and leave the site in a forward gear and-with a minimum head clearance (headroom) at any point of 2.2m. . All carparking must be kept and maintained in a condition fit for use. . Frontage Works 21. 22, 23. 24. Footpath improvements such as topsoiling, grassing, and tree planting are required to __ the Grant Street frontage of the site in accordance with Planning Scheme Policy PSPO03 Landscaping Ph jants & Guidelines. Grass must be couch, free of weeds. Anew 1.5m wide concrete path must be constructed along the Grant Street frontage of the site in accordance with Council's design standards and fo an alignment that protects any significant vegetation or any underground services. All paths, driveways and parking areas must be designed and constructed: to ensure pedestrian safety using non-slip materials, to produce an evenly graded surface finish, and to be in accordance with the Disability | Discrimination Act 1992 and Australian Standard 1428.1 Design for Access & Mobility. All redundant vehicular crossings to the site must be removed and replaced by kerb & channel, footpath paving and landscaping such as trees and grasses in accordance with Council’s Standard specifications prior to commencement of the use permitted by this permit. PD-DA-FM384/1-13/04/2010 - : . . Page 4 of 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
01072015144724.pdfRelated documentApplication case desk ↗
01072015144724.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.