Council archive · source document
05/1917 - SUPERSEDED Compiled Decision Notice [As Published] · 132005.1917.02
Form 6 – Compiled Decision Notice
INTEGRATED PLANNING ACT 1997, S3.5.15, IDAS DEVELOPMENT APPLICATION
File No: 2005/1917 Date of Decision: 23 May 2007
1. APPLICANT DETAILS
Name: Raphill Pty Ltd
Postal address: CARE Ken Hicks & Associates
PO Box 6380
MAROOCHYDORE QLD 4558
Phone no: 5443 2844 Fax no: 5443 7146
2. PROPERTY DESCRIPTION
Street address: 224-228 David Low Way & 3-5 Heron Street, Peregian Beach
Real property Lot 1 RP 152737 & Lots 75-78 P 9311, County of March, Parish of Weyba
description:
3. OWNER DETAILS
Name: Raphill Pty Ltd
Postal address: PO Box 186
PEREGIAN BEACH QLD 4573
4. REFERRAL AGENCIES
Referral Agency Address Basis
Environmental GPO Box 2771, Brisbane Qld 4001 Concurrence Agency -
Protection Agency Contaminated Land
5. APPLICATION TYPE
Development Development Details Preliminary Development
Approval Permit
Material Change of Use of Professional Office, Commercial No Yes
Premises Premises, Commercial Services, Medical
Centre, Shop, Restaurant & Multiple
Dwelling (3 units)
Reconfiguring a Lot 5 lots in to 3 lots No Yes
6. DECISION DETAILS
Council on 13 April 2006 decided to approve the application and grant a Preliminary Approval, subject to
conditions.
In relation to representations made by the Applicant, Council on 15 June 2006 decided to:
A. Grant a Development Permit for Material Change of Use of Premises for Professional Offices, Commercial
Premises, Commercial Services, Medical Centre, Shop, Restaurant & Multiple Dwelling (3 units) and
Reconfiguring a Lot – 5 lots into 3 lots subject to conditions contained in the Preliminary Approval, with the
following amendments.
B. Delete Conditions 1, 23, 45, 49, 50, 54, 123, 130 and 131.
C. Amend Conditions 4, 24, 27, 29, 36, 43, 48, 53, 109 and Items 5 & 10 contained within the Decision
Notice;
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 23 pages
Page 2
NOOSA COUNCIL IDAS Development Application Decision Notice 2 of 24
D. Include two additional conditions;
E. Refuse to delete Conditions 37, 41 & 66 for the following reasons:-
Condition 37
The amendment of Condition 4.1 and deletion of Condition 4.2 are to the satisfaction of the applicant and
therefore it is agreed to retain Condition 37.
Condition 41
The amendment of Condition 4.1 and deletion of Condition 4.2 are to the satisfaction of the applicant and
therefore it is agreed to retain Condition 41.
Condition 66
The works required as part of Condition 63 are not part of the Pathway Trunk Network and therefore
contribution to this network is still applicable.
F. Issue a Negotiated Decision Notice.
In relation to a request to change the development approval, Council on 23 May 2007 decided to:
A. Approve a change to Conditions 2, 4.1, 25, 59 & 109.
B. Issue a Compiled Decision Notice.
7. APPLICABLE CODES
The developer must comply with the following codes for self-assessable development related to the development
approved under this Development Permit:-
Nil.
8. SUBMISSIONS
One properly made submission & 2 not properly made submissions. See attached list.
9. CONDITIONS
The approval is subject to conditions. Noosa Council’s conditions are attached. Conditions from the
Environmental Protection Agency, as a concurrence agency are also attached.
10. FURTHER DEVELOPMENT PERMITS REQUIRED
Type of Development Permit required Subject of the required Development Permit
Development Permit for Building Works All building works
Development Permit for Operational Works Access and/or Carparking, Site Civil Works, Roadworks,
Stormwater Drainage, Frontage Works, Sewer Reticulation,
Water Reticulation, Site Filling, Excavation of Materials to fill
another site and Landscaping.
11. RIGHTS OF APPEAL
Rights of appeal in relation to this application are attached.
12. ASSESSMENT MANAGER
Name: Noosa Council Signature: Date: 25/05/07
DECISION NOTICE HISTORY
Original Decision Notice 13 April 2006.
Negotiated Decision Notice granting a Development
Permit with amendment to Conditions 4, 24, 27, 29,
36, 43, 48, 53, 109 and Items 5 & 10 of the Decision
Notice, deletion of Conditions 1, 23, 45, 49, 50, 54,
123, 130 and 131 and inclusion of two additional
conditions on 15 June 2006.
Minor change to the approval with amendment to
Conditions 2, 4.1, 25, 59 & 109 on 23 May 2007.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 3
NOOSA COUNCIL IDAS Development Application Decision Notice 3 of 24
Noosa Council Conditions
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
MATERIAL CHANGE OF USE OF PREMISES
Land Use
1. Deleted.
2. Development undertaken in accordance with this approval must generally comply with the approved plans
of development. The approved plans are titled and numbered:-
2.1. Ground Level Plan, First Floor Plan, Roof Plan, Elevations, Project No 0503, Revision A, prepared
by H2o Architects and dated 10 November 2006;
2.2. Survey Plan A0.02, Basement Plan A1.00 Revision 16, Sections A6.01 Revision 16, Project No
503, prepared by H2o Architects and dated 6 January 2006;
and as may be amended by these conditions
3. The development must be undertaken and operated in a manner that causes no detrimental effect upon
the amenity of the neighbourhood by reason of the creation of excessive noise, lighting nuisance or other
emissions.
4. The development shall incorporate the following amendments to the building design:-
4.1. The development shall have a maximum building footprint and a total site cover as shown on the
approved plans.
4.2. The development shall have a maximum gross floor area of 1,561m².
4.3. The timber pergola located on the corner or Kingfisher Drive and Heron Street shall not be located
within the road reserve;
4.4. The bin storage area located adjacent to the David Low Way street frontage shall be relocated and
the screening vegetation extended through to the property boundary;
4.5. Sight lines from the parking aisle that serves the 6 car parking spaces, accessed off the side of the
main entry driveway (under the medical centre), shall be improved as there is currently limited
vision of vehicles on the ramp without vehicles in the parking aisle having to protrude some
distance onto the actual ramp. A Traffic Engineer with appropriate qualifications in this area shall
certify the design at the Operational Works stage.
4.6. The main access ramp shall be widened / flared where it joins with the basement carpark (to the
south east of the proposed lift), to improve vehicle access onto the ramp, which is currently quite
tight to manoeuvre and results in vehicles having to turn into the path of oncoming traffic on the
ramp. A Traffic Engineer with appropriate qualifications shall certify the design at the Operational
Works stage.
4.7. A Traffic Engineer with appropriate qualifications shall certify the design at the Operational Works
stage with regard to the manoeuvring room at the southeast and southwest corners of the
circulation aisle of the basement carpark due to the positioning of the Plant Room and Bicycle
Parking Compound.
4.8. Access to the lift from the two disabled spaces shall be positioned to the east of this row of spaces
and any necessary modifications to the plant room, structure and/or adjacent spaces will be
included in the operational works application to ensure that a clear path to the lift is available for
use with appropriate headroom and width. A Traffic Engineer with appropriate qualifications shall
certify the design at the Operational Works stage;
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 4
NOOSA COUNCIL IDAS Development Application Decision Notice 4 of 24
5. The open space and setback areas are to be landscaped in accordance with Council’s Policy on
Landscaping Guidelines and a properly prepared landscape plan prepared by a suitably qualified
Landscape Architect or Horticulturalist. Such landscaping is to be completed prior to the premises being
occupied and maintained at all times thereafter. The landscaping plan is to include:-
5.1. The establishment of 45 litre screening vegetation to reach a height of 4 – 6 metres along the
length of the northern property boundary to ensure adequate screening for the adjoining
properties.
5.2. The provision of either of the following species within the courtyard areas:-
5.2.1. BANKSIA integrifolia, exground or 200 litre bag stock to be planted in groups of 5 & 7 in
the one podium planter box;
5.2.2. HIBISCUS tiliaceus (Cottonwood), exground or 400 litre bag stock, single planted in
planter box;
5.2.3. METROSIDEROS thomasii, exground or 2 x 400 litre bag stock, double planted in
planter box;
5.2.4. PANDANUS pendunculatus, exground, single planted in planter box.
5.3. The provision of additional landscaping to screening all waste storage areas.
6. Existing trees on the site and within road reserves are to be retained, except where required to be
removed due to building operations or the conduct of the approved use.
7. The proposed ramp walkway along the northern property boundary shall not be utilised for outdoor dining
purposes and shall be kept clear at all times.
8. The tenancies nearest the northern boundary of the site (shops 8 and 9 and the restaurant) shall maintain
a focus towards the courtyard areas with limited access to the proposed ramp/walkway in order to
minimise noise impacts on adjoining residential properties.
9. All deliveries associated with the Business Uses on the premises shall be undertaken only between the
hours of 7am to 7pm.
10. Business Uses shall operate only between the hours of 7am to 10pm, 7 days a week, except Friday and
Saturday where Entertainment and dining business uses may operate until 12 midnight.
11. Any gate constructed across the vehicle access to the site shall remain open between the hours of 7am to
10pm Sunday to Thursday and 7am to 12 midnight Friday and Saturday.
12. The amenity facilities (toilets) shall be available to patrons of the development for use during the operating
hours of businesses on site.
13. Ground floor premises shall provide a minimum 50% glazing to shop fronts.
14. Natural and muted earth tones shall be incorporated on external walls and roofing so as to integrate with
the natural environment.
15. Signage shall be integrated into the building façade and comply with Council’s policies on advertising.
16. Signage clearly delineating the upper level residential access from the upper level commercial access
shall be provided.
17. Arcade and courtyard paving shall be integrated with the paving types detailed in Council’s Peregian
Centre Masterplan.
18. Any additional mechanical plant and equipment shall be located greater than 2 metres from any property
boundary and shall be fully enclosed and integrated with a component of the building. Plans illustrating
this shall be submitted to Council to the satisfaction of Manager Land Use prior to the equipment being
installed.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 5
NOOSA COUNCIL IDAS Development Application Decision Notice 5 of 24
19. The bicycle racks located adjacent to the Heron Street property boundary shall be relocated within the
courtyard areas. Amended plans detailing this shall be submitted prior to obtaining a Development Permit
for Operational Works.
20. Lighting of appropriate intensities is to be provided which satisfies the requirements of Australian
Standard AS1158: Public Lighting Code.
21. The blank walls associated with the stairways, amenities and bin storage areas on the lower floors shall
incorporate measures in the form of landscaping, creepers, murals, vandal resistant paint, etc to deter
vandalism.
22. Lighting shall be directed on to the site and away from neighbouring properties.
23. Deleted.
24. The outdoor dining areas shall comply with Planning Scheme Policy 14 and shall only use flexible, roll-up
or drop plastic sheeting when adverse weather conditions prevail, and these should be cleaned regularly.
25. The development shall have a maximum height above natural and finished ground level of 8.4 metres
except for the flumes, which shall be constructed in accordance with plans titled and numbered
Mechanical Services Layout Roof Level Drawing No. Q0371-MS-07A dated 9 November 2006 and
Section & Schedules Drawing No. Q0371-MS-06C, Mechanical Services Layout Level 1 Drawing No.
Q0371-MS-05C and Ground Level – Part 2 of 2 Drawing No. Q0371-MS-04C dated 8 November 2006
prepared by Marc Air Conditioning Services. A verification survey of the building is to be carried out by a
Licensed Surveyor and a certificate lodged with Council at completion of work confirming compliance with
the this condition.
26. Any deck or balcony areas are not to be enclosed with shutters, glass panelling or the like, thus remaining
as open structures.
27. Security in the form of a cash bond or trading bank guarantee to the sum of $100 000 must be submitted,
to secure performance of all conditions of this approval, prior to the issue of a Development Permit for
Operational Work. The cash bond or trading bank guarantee will be returned on performance of the
conditions of approval less any costs incurred by Council in respect of enforcing performance of this
permit.
28. The developer must obtain all of the other Development Permits referred to in the Decision Notice, prior to
obtaining a Development Permit for Building Works.
29. This Development Permit lapses if the use has not happened by 15 June 2010, unless an application to
extend the currency is approved by Council.
Land Development
Vehicle Access
30. The main entry driveway off the David Low Way, which gives access to and from the proposed
development, shall be designed and constructed as a left-in / left-out access driveway with no right turn
movements permitted to or from the development and shall incorporate a pavement threshold to define a
significant change in road environment to entering motorists.
In accordance with the Australian Standard for Off Street Car Parking AS2890.1-2004 both the entry and
exit must be separated by a central traffic island with a 6m wide entry and a 4-6m wide exit, separated by
a 1-3m wide traffic island.
In this regard the traffic island shall be shaped to promote a left-in entry and a left-out exit, with a break in
the island to allow the smooth flow of pedestrians along the footpath without the need for pedestrians to
step up onto the traffic island. The proposed traffic island shall also extend down part of the driveway
ramp to help guide vehicles in the correct direction and not into the path of oncoming vehicles.
31. A centre median shall also be provided on the lower portion of the main entry driveway (where the
driveway bends to the south to provide access into the basement carpark) to ensure vehicles travel on the
correct side and do not stray into the path of oncoming vehicles. This median need only be 200mm wide
x 150mm high.
32. The driveway shall be designed and constructed to grades that prevent vehicles from scraping and/or
bottoming whilst also allowing pedestrians movements along the footpath without any level difference.
Should any driveways be constructed to grades that do not comply with AS2890.1-2004 and AS2890.2-
1989, Council will require that the driveway be removed and reconstructed to levels that do comply.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 6
NOOSA COUNCIL IDAS Development Application Decision Notice 6 of 24
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
33. All vehicles shall enter and leave the site in a forward direction.
External Roadworks
34. The applicant shall provide a centre traffic median within the David Low Way extending from the existing
roundabout splitter island along the entire frontage of the site (up to a point in-line with the northern
boundary of Lot 1 on RP 152737, #228 David Low Way and the southern boundary of Lot 0 on BUP
101281, #232 David Low Way) to prevent vehicles from turning right into/from the development.
35. Any roadworks widening and associated works (including pavement correction to the existing pavement,
drainage works, modification of the footpath, landscaping, and adjustments to the existing infrastructure)
that may be required as a result of the new centre traffic median shall be at no cost to Council. In this
regard, plans detailing this work shall be prepared and submitted to Council for approval prior to obtaining
a Development Permit for Operational Works.
36. A safe U-turn facility shall be provided along the David Low Way to the north of the development, and
within close proximity to the site, to enable northbound traffic the ability to U-turn in order to gain entry to
the development. The provision of this facility shall be at no cost to Council, as the facility is needed to
enable patrons of the development the ability to safely turn around. This facility shall be constructed prior
to the approved use commencing.
As an alternative to construction of the U-turn facility, Council may elect to enter into an Infrastructure
Agreement with the applicant for the future roundabout to be constructed at Woodland Drive in
accordance with the Coastal Major Roads Network Infrastructure Charges Plan (CMRNICP). This
agreement would need to address, but not be limited to:
Who pays for the design;
Who constructs the infrastructure;
The amount of costs to be borne by each party, recognising that the costs associated with
constructing the roundabout prior to Council’s programme of 2010 will be the applicant’s;
Use of CMRNICP contributions paid by this development towards the roundabout cost;
All costs involved with the preparation of any Infrastructure Agreement will be borne by the applicant..
37. A pedestrian priority crossing shall be provided in Heron Street between Courtyard E of the new
development and the existing Peregian Centre on the southern side of Heron Street at no cost to Council.
This crossing shall be designed as a shared zone and be consistent in design, form and function with the
two existing shared zones in the precinct. Plans illustrating the design shall be submitted to Council prior
to obtaining a Development Permit for Operational Works.
38. To cater for increased pedestrian movements, in a north south direction at the Heron Street / David Low
Way intersection, kerb ramps shall be installed and a pavement threshold shall be provided in Heron
Street to define a significant change in road environment to motorists entering Heron Street from the
David Low Way.
39. To cater for increased pedestrian movements in a north south direction at the Heron Street / Kingfisher
Drive intersection, kerb ramps shall be installed.
40. The northern leg of the roundabout at Heron Street shall be provided with kerb ramps and a safe at grade
gap in the central median island to facilitate safe pedestrian access in an east west direction.
41. A raised at grade platform for pedestrians shall be provided in Kingfisher Drive (south of the proposed
Delivery / Garbage collection bay) at the intersection with Heron Street to enable pedestrians to cross
safely in an east west direction. This platform will by its physical nature be slow speed and shall fit in with
the shared zone strategy for the precinct.
42. A 2m wide pathway shall be provided between the new kerb ramps and the existing / proposed pathway
network.
43. A linemarked on road bicycle lane shall be provided on the David Low Way adjacent to the site at no cost
to Council, the works shall include removal of existing lines and linemarking in accordance with Council
requirements.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 7
NOOSA COUNCIL IDAS Development Application Decision Notice 7 of 24
44. All roadworks upgrading shall be designed by a suitably qualified Registered Professional Engineer
Queensland (RPEQ) and submitted to Council for approval prior to obtaining a Development Permit for
Operational Works.
Roadworks Contributions (Local Road Network)
45. Deleted.
Loading / Delivery Areas
On Street Delivery Area
46. A Delivery / Garbage collection bay shall be provided within the Kingfisher Drive road reserve at no cost to
Council. This bay shall be sized appropriately to facilitate the requirements of a Council refuse collection
vehicle, giving consideration to the number of bins to be serviced and the room / length needed to store
and service these bins along the verge. In this regard a wheelie bin is 600mm wide and each wheelie bin
is required to be spaced approximately 500mm apart to allow adequate room for the collection arm of the
refuse truck to be able to collect each bin.
The Delivery / Garbage collection bay shall also be positioned to provide separation to the new pedestrian
crossing across Kingfisher Drive (south of the bay), as required by conditions within this permit, and shall
not restrict sight lines to pedestrians approaching the crossing. The 2m pathway adjacent to this bay shall
be aligned to provide continuous use by pedestrians even when bins are placed for collection.
47. The Delivery / Garbage collection bay shall be appropriately line-marked and signposted to prevent
misuse and be kept and maintained in a condition fit for use. In this regard a regulatory sign shall clearly
define the maximum length of time a delivery vehicle can remain parked to ensure the bay is available for
use by other delivery vehicles and the Council refuse vehicle.
Off Street Delivery Area
48. The proposed shared “Pedestrian / Vehicle / Ambulance / Small Rigid Vehicle (SRV)” zone located on the
parking aisle between the 6 car park spaces accessed off the side of the main entry driveway (under the
proposed medical centre) is not approved.
Accordingly the parking aisle shall be used for the purposes of gaining entry to the 6 car parking spaces
only, and not combined with an ambulance / delivery space.
49. Deleted.
Carparking
On Street
50. Deleted.
Off Street
51. Carparking shall be provided within the site as shown on drawing number A1.01, revision 16, dated
06/01/06, by H2o Architects Pty Ltd (Project No. 0503), except as modified herein.
52. The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for user class 3
with allowance for vehicles to enter and leave the site in a forward gear and with a minimum head
clearance (headroom) at any point of 2.2m.
53. All disabled car park spaces shall be designed to comply with the provisions of AS 2890.1-2004 for user
class 4 with allowance for vehicles to enter and leave the site in a forward gear with a minimum head
clearance of 2.3m and with a minimum head clearance (headroom) of 2.5m above the space from the
point of entry to the space to a point 2.16m from the front.
54. Deleted.
55. Signage shall be provided to all frontages of the development to advise/direct patrons to the basement
carpark.
56. All owners / tenants shall be required to inform their visitors / customers of the basement car parking
arrangements, particularly when such patrons are required to make an appointment or booking (as is
often the case for a Medical Centre Uses and Restaurant Uses). These requirements shall be
incorporated into the Community Management Scheme for the development and a copy submitted to
Council for approval prior to the approved Uses commencing.
57. All car parking shall be kept, maintained and line-marked in a condition fit for use.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 8
NOOSA COUNCIL IDAS Development Application Decision Notice 8 of 24
58. At least 2 motorcycle/motorscooter spaces shall be provided on site, and in this regard a maximum of 1
carparking space shall be permitted to be removed/altered to accommodate these 2 spaces. These 2
spaces should be positioned close to the main entry ramp that enters the basement carpark to allow
people travelling on motorcycle or scooter to quickly locate a parking space without having to park in a
standard car park space.
Bicycle Facilities
59. End of trip bicycle storage facilities, showering facilities and changing rooms shall be provided in
accordance with Council’s latest policies to encourage cycling and walking to the development by staff
and customers.
Vegetation Protection & Preservation
60. Vehicular pavements within the drip zone of any proposed trees on site (or existing trees to remain) shall
be designed as a pervious pavement (such as grass paving cells or similar), to allow water that falls on
this surface to penetrate to the trees root system. The pavement shall be constructed so as not to
damage the tree or their root system and in this regard temporary fencing may need to be provided
around existing trees during construction to help protect them.
Plans shall be submitted to the Council for approval that clearly show the type and extent of the pervious
pavement and the temporary fencing prior to obtaining a Development Permit for Operational Works.
Park Contributions
61. A Park contribution of $3,616 towards the acquisition of additional parkland or the improvement of existing
parkland and facilities in the locality shall be paid to the Council prior to obtaining a Development Permit
for Operational Works in accordance with Council’s Planning Scheme Policy PSP24 Park Requirements
for Development Applications. This amount will be subject to variations in the Consumer Price Index, All
Groups Brisbane from December 2005 until the date of payment.
Frontage Works
62. Footpath improvements such as topsoiling, grassing, and tree planting (with low shrubs and shade trees)
shall be provided to all road frontages of the site (i.e. the David Low Way, Heron Street, and Kingfisher
Drive) in accordance with Planning Scheme Policy PSP1 Landscaping Guidelines and the Peregian
Centre Master Plan, to the satisfaction of the Manager – Design, Works Directorate. This landscaping
shall not obstruct safe road use and safe conditions for pedestrians and cyclists by limiting sight lines. All
grass shall be couch, free of weeds.
63. A new 2.0m wide concrete path shall be constructed along all frontage of the site (i.e. the David Low Way,
Heron Street, and Kingfisher Drive), in accordance with Council’s design standards and to an alignment
that protects any significant vegetation or any underground services.
64. All paths and kerb ramps shall be designed and constructed to ensure pedestrian safety using non-slip
materials and to produce an evenly graded surface finish.
65. All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel, footpath
paving and landscaping such as trees and grasses in accordance with Council’s Standard specifications
prior to commencement of the use permitted by this permit.
Pathway Contributions
66. A pathway contribution of $813 towards external major pathways, in accordance with Planning Scheme
Policy PSP41 Pathway Trunk Network Contributions, shall be paid to the Council prior to obtaining a
Development Permit for Operational Works. This amount will be subject to variations in the Consumer
Price Index, All Groups Brisbane from December 2005 until the date of payment.
Internal Pedestrian Pathways
67. All internal pedestrian ramps and pathways shall be designed and constructed to ensure pedestrian safety
using non-slip materials and to provide disabled access in accordance with the appropriate Australian
Standards.
Undergrounding Power
68. All existing overhead electricity wires to the frontages of the development (David Low Way, Heron Street,
& Kingfisher Drive) shall be redirected underground to help beatify the streetscape and aid with the growth
of street trees. This work shall be at no cost to Council.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 9
NOOSA COUNCIL IDAS Development Application Decision Notice 9 of 24
Stormwater Drainage
69. All stormwater drainage shall be collected on site and discharged so there is no net increase in
stormwater runoff from the site. Stormwater drainage permitted to drain from the site shall be discharged
to Council’s existing drainage structures in Kingfisher Drive. Plans of the drainage design shall be
prepared by a Registered Professional Civil Engineer and submitted to Council prior to obtaining a
Development Permit for Operational Works. In this regard the capacity of Council’s existing drainage
system shall be determined in order to ensure that the existing system has capacity to carry additional
flows.
70. Roof runoff from any new buildings shall be directed to a rainwater storage system or tank (with a
2
minimum storage capacity of 12 litres/m of roof area) that is installed to ensure water from the tank can
be used for external uses (such as watering gardens, irrigation, ornamental ponds, water features,
topping-up swimming pools, outdoor cleaning, etc) and for use in flushing of toilets internal to the building.
All rainwater tanks are to be designed and installed in accordance with the Queensland Development
Code (QDC), Part 25 – Rainwater Tanks, and to the satisfaction of Council’s Manager Plumbing Services.
The location and capacity of the tanks shall be clearly shown on the plans submitted for Building Works
approval and any overflow shall be directed to the stormwater drainage system for the development.
71. All stormwater on site, except roof water, shall be discharged through an approved Gross Pollutant Traps
(GPT) prior to being permitted to discharge into Council’s drainage system.
To this end, a detailed maintenance plan shall be prepared for the GPT, which shall be submitted to the
Council for approval prior to obtaining a Development Permit for Operational Works.
The approved maintenance plan shall be incorporated in the Community Management Scheme for the
development (if no Community Management Scheme then in the development’s maintenance plans) and
a copy of this shall be provided for Council’s records prior to commencement of the approved Use.
72. Any GPT proposed within the basement carpark shall be capable of being serviced and maintained by
ensuring sufficient head clearance over the GPT.
73. All site stormwater drainage shall be by means of a gravity system in accordance with section 3.4.4.12 of
Council’s Planning Scheme.
74. All stormwater drainage lines that will become a Council asset shall be inspected by closed circuit
television (CCTV) prior to commencement of the approved Use.
CCTV inspection will be carried out by Council's CCTV contractor and arranged by Council following
satisfactory completion of construction works. The developer will be responsible for the full cost of CCTV
inspection, including any additional inspection necessary following defect identification and rectification.
This charge is payable prior to the issue of Operational Works approval and will be determined on the unit
rate basis current at the time of approval.
75. Plans of the drainage scheme shall be prepared by a Registered Professional Civil Engineer and
submitted to Council prior to obtaining a Development Permit for Operational Works. The applicant shall
note that a Development Permit for Building Works will not be granted until a Development Permit for
Operational Works has been issued in regard to the drainage scheme.
Sewer Mains
76. The site shall be connected to Council’s existing sewerage reticulation systems and be constructed in
accordance with Council’s standards and requirements at no cost to Council.
77. The existing sewer main that currently crosses part of the site shall be relocated at no cost to Council to
make way for the new development and basement car park.
78. All existing and/or future sewer mains within the site or adjacent to the site which are intended to remain,
shall be accurately located by a licensed Surveyor whom shall determine their ‘zone of influence’ (taken
as the area within a 45-degree angle measured from the invert of the sewer main to the finished surface
level) and arrange for easements to be created over these mains where the ‘zone of influence’ impacts on
the subject site.
This ‘zone of influence’ for both existing sewer mains and proposed sewer mains shall be shown on all
plans submitted for Operational Works approval and Building Works approval to ensure no damage
occurs and no encroachments result.
79. To ensure Council’s sewer mains are accessible for maintenance purposes and are protected from risk of
damage, no structures requiring a building permit (eg. buildings, swimming pools, retaining walls
exceeding 1m in height, raised terraces, etc) shall be constructed within this ‘zone of influence’ and as
such the applicant shall amend Operational Works plans, including Building plans to ensure compliance.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 10
NOOSA COUNCIL IDAS Development Application Decision Notice 10 of 24
Town Water Supply
80. The site shall be connected to Council’s existing town water supply and be constructed in accordance with
Council’s standards and requirements at no cost to Council.
81. Each water connection to the water reticulation system shall extend to the property boundary and be
metered. Where multiple units including leased buildings are served by a single service, multiple water
meters to each individual unit or leased building shall be installed. All fees for the supply of water meters
shall be paid to the Council.
Service Easements (Sewer / Stormwater)
82. A registered easement shall be created over the ‘zone of influence’ of all sewers within the subject site
and over those parts of the subject site that are impacted upon by sewers on any adjoining sites. The
easements shall generally be parallel to and centred over the sewer main and be equivalent in width to
twice the depth to invert level of the sewer at the deepest point within the allotment (measured from the
finished surface) and be no less than 3.0m wide. In this regard a licensed surveyor shall accurately locate
all sewer mains and determine the necessary width of the easement, which shall be shown on any plans
submitted for Operational Works / Building Works approval. To this extent the surveyor shall certify that
the sewer and the zone of influence is wholly contained within the easement to be created.
In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in
writing that the Title Deed and the easement documents will be lodged at the Land Titles Office and any
additional Titles Office forms or requisitions requiring the consent of Council will be attended to promptly.
A duly executed copy of the easement shall be submitted to Council for perusal prior to the use
commencing.
Any changes required by Council’s Solicitor must be corrected immediately.
83. A registered easement shall be created over any stormwater drainage pipes within the site that collect
stormwater from a Council road or convey stormwater from any adjoining property (for example, where
drainage pipes are provided within the site to prevent adjacent properties from additional ponding/flooding
due to works on the subject site).
Headworks Contributions
84. Contributions shall be paid to Council in accordance with Planning Scheme Policies PSP28 and PSP30
on Water Supply Headworks Contributions and Sewerage Headworks Contributions respectively and at
the rates applicable at the time of payment. An estimate only of the contribution rates under the current
policies is outlined below. These amounts will adjusted in line with changes to the Consumer Price Index,
All Groups Brisbane from December 2005 until the date of payment.
Water Supply $10,059
Sewerage $27,965
TOTAL $38,024
All headworks contributions must be paid prior to the issue of a Development Permit for Operational
Works.
Alternatively a trading bank guarantee shall be submitted to Council plus 20%. Should the headworks
contributions not be paid at the due time, Council shall call upon the trading bank guarantee in full.
In the event that the Development Permit for Material Change of Use of Premises lapses or is cancelled,
the contribution or trading bank guarantee will be returned.
Site Stability
85. A Geotechnical Engineer or similar qualified expert shall assess the soil condition on site, determine the
soil classification, establish whether any measures are required to protect the stability of adjoining
buildings and/or structures, and make recommendations on the type of foundation system (including
retaining wall structures) best suited for the proposed development. This information shall be submitted to
the Council for assessment and approval prior to obtaining a Development Permit for Operational Works.
Earthworks
86. A Geotechnical engineer must be on site to supervise and direct all excavation works, and foundation
constructions (i.e. Level 1 supervision in accordance with AS3798-1996). Such work shall only be carried
out during dry weather conditions. Should any risk of soil movement occur - all work shall be suspended
until steps (approved by the Geotechnical engineer in conjunction with Council’s Manager of Building
Services) have been taken to ensure that no further slippage will result.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 11
NOOSA COUNCIL IDAS Development Application Decision Notice 11 of 24
87. Boundary wall movement shall be monitored throughout construction and if movement occurs -
construction is to be stopped immediately and appropriate action is to be taken to arrest the movement.
Further work shall only take place after a re-assessment of the conditions on site by the Geotechnical
engineer and Noosa Council’s Manager of Building Services.
88. Earthworks carried out on site shall not affect the structural integrity of any of the existing fences or
structures that border the development site. In this regard any fences to be replaced shall be clearly
shown on the plans submitted for Operational Works approval. Fences that are affected shall be replaced
prior to the Building Certifier issuing the Certificate of Classification.
89. The builder, landscaper and all workers associated with the construction of the proposed development
shall at all times comply with the directions of the Geotechnical engineer and the reasonable and lawful
directions of Council officers.
90. Any filling works required on site shall be carried out in accordance with Section 3.8 of Council’s
Engineering Design Standards Manual and so as not to cause the ponding of water on any adjoining
lands or the blockage of, or interference with, any natural watercourses. Detailed site surveys indicating
natural surface levels and contours of the adjoining properties must be provided with the application for a
Development Permit for Operational Works for Filling and Drainage.
91. A Registered Professional Engineer Queensland shall certify all designs and certify that he or she has
supervised all engineering works and that all works have been completed in a workmanlike manner in
accordance with the Australian Standards and good engineering practice.
Construction Issues
92. A Construction Management Plan (including a Traffic Management Plan) addressing all construction
phases shall be prepared by suitably qualified persons in consultation with the Peregian Beach Business
Association and submitted to Council for approval prior to obtaining a Development Permit for Operational
Works. The report should aim to address every foreseeable problem that is likely to occur during the
construction process and include recommendation on how these can be overcome or minimised and shall
also address parking for construction workers.
To ensure construction is undertaken appropriately, the Construction Management Plan shall also include
a section written by a Geotechnical engineer addressing the excavation and surrounding site support
systems.
93. A Condition Survey is to be carried out on adjoining buildings, structures and services prior to any
excavation or construction works taking place on site. If distress already exists, a photographic survey
shall be undertaken, the distress measured and a plan to monitor changes to distress shall be
implemented. A copy of this report is to be submitted to Council within 5 business days of the survey and
prior to construction work proceeding.
This report will be held by Council until all work is completed and will be used for verification purpose and
to ensure that all buildings, structures and services are left in at least the same state as before
construction commenced.
94. The use of vibratory equipment of any kind is not permitted to be used (including vibrating rollers and the
use of vibrating installation techniques for sheet piling and other construction vibrations caused by
excavating, earthmoving or demolition machinery or other similar construction techniques) unless
approved and supervised by a Certified Geotechnical Engineer. Under such circumstances the operator
of such equipment shall at all times comply with the directions of the Geotehcnical engineer and the
reasonable and lawful directions of Council officers.
The proposed use of such equipment shall be detailed in any application for a Development Permit for
Operational Works.
Erosion and Sediment Control
95. Any person acting on this permit shall prevent erosion and sediment export from leaving the site. Site
control measures such as silt fencing, controlled gravel access to the site and controlled disposal of
waste, will be necessary.
In this regard plans detailing the methods of controlling erosion and sediment are required to be submitted
to the Council for approval prior to obtaining a Development Permit for Operational Works.
General
96. A suitably qualified Registered Professional Engineer shall prepare engineering drawings and
specifications for all engineering works that will become Council infrastructure, which shall be submitted in
conjunction with an application for a Development Permit for Operational Works. In this regard a
DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be submitted in conjunction
with any application for Operational Works.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 12
NOOSA COUNCIL IDAS Development Application Decision Notice 12 of 24
97. Digital detailed design drawings and calculations shall be submitted with any application for a
Development Permit for Operational Works in respect of roadworks and stormwater drainage works. To
avoid conflict with underground pipes or services, all existing and proposed services required by the
development shall be shown on the plans.
98. To facilitate production of As Constructed drawings it is suggested that all design drawings are submitted
in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC are
available at www.adac.com.au).
99. Any damage caused to any public utility during the course of construction shall be repaired to Council’s
standards and at no cost to Council.
100. Any alteration of any public utility or other facilities necessitated by the development of the land or
associated construction works external to the site shall be at no cost to Council.
101. The transportation of all materials to and from the site shall be undertaken in a manner such that no
particle matter escapes onto a public road. All vehicles carrying materials either to or from the site shall
be covered to prevent materials including dust being windblown from the vehicle.
102. As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer for design
intent, and a Licensed Surveyor shall certify the cadastre and the location, level and type of all services
and structures. All of which shall be submitted to Council for checking and for Council’s records.
The data must fully detail levels for all engineering works including but not limited to drainage structures,
finished ground levels and pavement surface levels. The data shall be submitted in the Asset Design and
As Constructed (ADAC) digital format. (Guidelines on the use of ADAC are available at
www.adac.com.au).
Approval of works shall not be granted until all As Constructed information has been supplied and
accepted by Council.
Environmental Health
103. Waste storage and disposal facilities must generally comply with Planning Scheme Policy No:9 “Waste
Management Multi-Dwellings and Commercial and Industrial Premises”.
104. The waste storage area at David Low Way is to be relocated and serviced from Kingfisher Drive. The
additional waste storage area is to be shown on the site plan.
105. The external bin wash area (4m x 2m) at the eastern end of the complex is to be provided with;
105.1. Approved screening to the northern and eastern sides;
105.2. Cold water tap, hose and drain outlet connected to the sewer.
106. The off-street refuse pick-up bay in Kingfisher Drive is to be increased in length in a southerly direction to
suit the length of a refuse vehicle, of a minimum of 11 metres. Clear turning circles must be met.
107. The waste storage area at the rear of the restaurant is to be provided with mechanical exhaust ventilation,
as natural ventilation is not permitted in the Acoustic Consultant’s Report.
108. On-site litterbins are to be provided within each courtyard.
109. Four combined street litterbins and smokers bins to a design approved by Council’s Environmental Health
Section shall be supplied and installed at the developers expense at the following locations:-
109.1. On or near the footpath area at the end of the Pedestrian Arcade adjacent to the David Low
frontage of the site;
109.2. On or near the footpath area adjacent to the pedestrian crossing along the Kingfisher Drive
frontage of the site; and
109.3. On or near the footpath area adjacent to both courtyards W and E along the Heron Street frontage
of the site.
Details of the location and design of these shall be submitted to Council for approval prior to the issuing of
Operational Works.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 13
NOOSA COUNCIL IDAS Development Application Decision Notice 13 of 24
110. Refuse containers must be provided in accordance with the requirements of the Environmental Protection
(Interim Waste) Regulation 1996 and (Waste Management) Regulation 2000, for the storage and
collection of refuse.
Noise
111. Strict compliance with the Acoustic Consultant’s TTM Consulting P/L. Report No: 50596 dated September
2005, 20 December 2005 and 21 February 2006. Upon completion of the development and prior to any
occupation, the Acoustic Consultant is to provide written certification to Council that the development is in
accordance with their recommendations.
112. Submission of a further acoustic report to Council for approval prior to the issue of a development consent
for building works, that shows final details of the noise control measures for the car park exhaust,
restaurants cooking, refrigeration and waste storage room ventilation systems and compliance with
Council’s Local Law 12 – Control of Nuisances and the Environmental Protection Regulation 1998.
113. An acoustic barrier is to be provided on the roof above the restaurants in accordance with the Acoustic
Consultant’s TTM Consulting P/L Report No. 50596 dated 21 February 2006.
114. The eastern ground floor outdoor dining area is not to be used after 10pm. All patrons are to leave this
area prior to 10pm, and restaurant doors leading to this area kept closed after 10pm.
115. The exhaust ventilation ducts from the restaurants must be relocated a minimum 6 metres from the
northern boundary.
116. The proposed fixed glazing to the eastern external wall of Apartment 3 is to be of sufficient density to
prevent noise nuisance from patrons and music noise from the two restaurants.
117. All plant, equipment or motors for the basement air intake are to be located within the basement car
parking area.
118. Noise emission from air conditioning equipment shall comply with the following requirements:
118.1. The equipment shall be installed and located in a manner that prevents excessive noise in
accordance with Council’s Local Law No. 12 - Control of Nuisances. Infringement Notices (on-the-
spot fines) may apply for offences.
118.2. Submission of written certification from a suitably qualified person confirming that the noise levels
comply when measured at either the residential boundary or outside the most exposed part of an
affected building, whichever is the closest to the equipment. This is required immediately after
installation of the equipment and prior to any occupation of the building, and in a format approved
by Council.
118.3. A person must not use equipment on any day if it makes or causes noise to be made –
118.3.1. From 10pm to 7am: More than the lower of either –
40 dB(A)
3 dB(A) above the background noise level
118.3.2. From 7am to 7pm: More than the lower of either –
50 dB(A)
5 dB(A) above the background noise level
118.3.3. From 7pm to 10pm: More than 3 dB(A) above the background noise level.
Trade Waste
119. Liquid waste generated by industry, small business and commercial enterprises is referred to as Trade
Waste and shall comply with the following:
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 14
NOOSA COUNCIL IDAS Development Application Decision Notice 14 of 24
119.1. A Trade Waste Permit shall be obtained prior to the discharge of trade waste to Council’s
sewerage system.
119.2. All trade waste requirements complying with Council’s Trade Waste Policy and including pre-
treatment devices, must be shown on hydraulic plans submitted to Council for approval prior to
issuing the development permit for building work.
119.3. Vehicular access shall be provided to each grease arrestor and/or pre-treatment device for
cleaning and servicing by Council’s contractor, and must allow vehicles to enter and leave the site
in a forward direction. Where access is restricted, a pump out line to an approved location is
required.
119.4. Trade waste requirements must be in place, inspected and approved prior to commencement of
trading or operation.
120. Bin washing areas for commercial and industrial developments exceeding 600mm x 600mm shall be
roofed and the floor fall to a bucket trap prior to discharge to the sewer. Rainwater should be excluded
from the bin washing area. Bin washing should take place only at the bin washing area.
121. Each restaurant must be provided with its own 1000lt grease arrestor as follows;
121.1. Located in the basement car park floor directly beneath the restaurants
121.2. Be provided with trafficable lids
121.3. Be provided with draw-off lines to a common location in the landscaped area adjoining Kingfisher
Drive.
122. Future food premises eg; café, coffee shop, take-away are required to have specific trade waste facilities
including a dedicated sewerage line connected to a grease arrestor located at the eastern end of the
basement car park. A common grease arrestor of 2000 litres may be shared. These facilities should be
installed during the initial construction stage, otherwise certain types of food premises may not be able to
be approved in the future.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 15
NOOSA COUNCIL IDAS Development Application Decision Notice 15 of 24
RECONFIGURE A LOT
123. Deleted.
124. The lot reconfiguration / amalgamation shall generally be in accordance with proposal plan S05-0123.1,
dated 19/09/05 by Urban Strategies, except as modified herein.
125. For the purpose of conditions contained within this permit, a Plan of Survey means the plan for the
reconfiguration of a lot required to be endorsed by Council pursuant to S3.7.1 of the Integrated Planning
Act 1997.
126. In conjunction with the lodgement of the Plan of Survey for Council endorsement, legal documentation
shall be presented to Council and shall be submitted in the correct form with the fees prescribed in
Council's adopted fee schedule.
127. Prior to Council endorsing the Plan of Survey, a duly executed copy of any required Grant of Easement
shall be submitted to Council for perusal.
Any changes required by Council’s Solicitor shall be attended to prior to endorsing the Plan of Survey.
Any necessary Titles Office forms requiring the consent of Council is to be submitted prior to the
endorsing of the Plan of Survey.
128. Prior to the endorsement of the Plan of Survey, the Applicant's Solicitor shall give Council's Solicitor an
appropriate undertaking in writing that in conjunction with lodgement of the Plan of Survey at the Land
Titles Office, the Title Deed and the easement documents will also be lodged and any additional Titles
Office forms or requisitions requiring the consent of Council being attended to forthwith.
129. Pursuant to Section 3.7.3(3)(b) of the Integrated Planning Act, all outstanding rates and charges due and
payable to Noosa Council in respect of the lots being reconfigured shall be paid prior to endorsement of
the Plan of Survey.
130. Deleted
131. Deleted.
Additional Conditions 15/06/06
MATERIAL CHANGE OF USE OF PREMISES
132. Payment of a contribution to Council in lieu of two (2) off-street car parking spaces in accordance with
Council’s Policy on Cash Contributions in Lieu of the provision of Off Street Carparking, prior to issue of
Operational Works Approval. Such payment shall be in accordance with the contribution rate adopted by
Council at the time the application was lodged and shall total $21,380.00.
133. Prior to the use commencing, a certificate from a registered Professional Civil Engineer shall be submitted
to Council for each Development Permit for Operational Works issued pursuant to this permit. The
engineer shall certify that he has supervised those works and that they have been completed in a
workman like manner in accordance with good engineering practice and in accordance with that permit.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 16
NOOSA COUNCIL IDAS Development Application Decision Notice 16 of 24
Concurrence Agency Conditions –
Environmental Protection Agency
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 17
NOOSA COUNCIL IDAS Development Application Decision Notice 17 of 24 A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 18
NOOSA COUNCIL IDAS Development Application Decision Notice 18 of 24 A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 19
NOOSA COUNCIL IDAS Development Application Decision Notice 19 of 24 A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 20
NOOSA COUNCIL IDAS Development Application Decision Notice 20 of 24
Local Laws, Policies & State
Regulation Requirements
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
THE FOLLOWING ADVICES ARE FOR INFORMATION PURPOSES ONLY AND DO NOT FORM
CONDITIONS OF APPROVAL
1. The applicant is informed that approval of this development application will trigger an Infrastructure
Charge in accordance with the Coastal Major Road Network Infrastructure Charges Plan for the estimated
amount of $242,458 and is subject to variations in the Consumer Price Index, All Groups Brisbane from
December 2005 until the date of payment. An Infrastructure Charge Notice will be issued in accordance
with Chapter 5 of the Integrated Planning Act 1997.
2. It is recommended that the applicant incorporate the principles of Council’s TravelSmart Noosa Program
to encourage mode shift and create improved access to the development.
3. The applicant is informed that payment via credit card transaction will not be an acceptable method of
payment for development contributions conditioned in this permit or for infrastructure charge notices
issued separately.
4. The applicant is advised that a Compliance Permit for all plumbing and drainage works within the
boundaries of the development site shall be obtained from Council’s Plumbing Services Section prior to
obtaining a Development Permit for Building Works.
5. Where any food premises is to be included in the development, the following is required:
5.1. Plans and an application should be made to Council’s Environmental Health Section for approval
prior to any building approval, fitting out or use of the premises.
5.2. Construction and use of the food premises should comply with Council’s Food Premises Policy and
the Food Safety Standards.
5.3. Toilets for customers and staff should be provided in accordance with the Building Code of
Australia. Obtain advice from a building certifier.
5.4. Plans and approval is required for any mechanical exhaust ventilation system which should comply
with AS1668. A certificate is required from the installer certifying the system complies with the
Standard.
5.5. Licence and registration is required for any food premises listed in Schedule 1, Food Hygiene
Regulation 1989, prior to use of those premises.
5.6. A detailed statement indicating the purpose of the food premises, type of food sold, proposed
menu and number of persons served, is to accompany the plans approval application.
6. The number of patrons for each of the restaurants will be determined by the size of the kitchen and the
adequate provision of all other required facilities.
7. A mechanically ventilated air-lock may be required between the waste storage room and the “back of
house” area of the ground floor restaurant.
8. The operator of any body piercing or tattooing business should comply with the Public Health (Infection
Control for Personal Appearances Services) Act 2003 and:
8.1. Obtain a licence to operate prior to commencing the use.
8.2. Comply with the Infection Control Guidelines of the Act.
8.3. Premises to comply with the standard in Part 15 of the Queensland Development Code.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 21
NOOSA COUNCIL IDAS Development Application Decision Notice 21 of 24
9. The operator of any beauty treatment and/or hairdressing business should comply with the Infection
Control Guidelines of the Public Health (Infection Control for Personal Appearances Services) Act 2003.
10. All refrigeration plant including motors, should be situated within the building or suitably provided with
noise reduction measures and located as to prevent a noise nuisance in accordance with the nuisance
provisions of the Environmental Protection Regulation 1998. On the spot fines apply for such offences.
11. In accordance with the Environmental Protection (Water) Policy 1997, all sand, silt, mud, paint, cement,
concrete, builder’s waste or rubbish should not be permitted to enter or be placed where it could
reasonably be expected to move into a roadside gutter, storm water drain or a watercourse. On the spot
fines apply for such offences.
12. The plans for the proposed building work have not been assessed for compliance with the requirements of
the Building Code of Australia as they relate to people with disabilities. Your attention is drawn to the
matter that either or both the Disability Discrimination Act 1992 (commonwealth) and the Anti-
Discrimination Act 1991(Queensland) may impact on the proposed building work.
Noosa Council recommends that the following matters be considered to address equitable access and
facilities in the building:
12.1. The building and environs should be designed to meet the requirements of the Human Rights and
Equal Opportunity Commission “Advisory Notes on Access to Premises” and AS1428.2;
12.2. Applicants should be aware that a “Disability Standard on Access to Premises is being developed
and most likely will result in changes to the Building Code of Australia;
12.3. Any services and facilities in the building complex must allow independent, dignified and equitable
use of the services and facilities for all people.
13. This proposal has not been assessed in relation to the spread of fire between properties / buildings. It is
the building certifiers responsibility to assess the requirements for fire services, fire separation and
appropriate methods of construction as part of the building works approval process. Referral to the
Queensland Fire and Rescue Service (QFRS) may be required as part of the Building Approval process.
14. Prior to the commencement of the development, a plumbing assessment must be obtained from Noosa
Council’s Plumbing Services Section in accordance with the Plumbing & Drainage Act 2002 (as
applicable).
15. Pursuant to the Building and Construction Industry (Portable Long Service Leave) 1991 Act if the cost of
operational works exceeds $80,000, then a portable long service leave levy is required to be paid. In
accordance with Section 77.(1) of the Act, Council is required to sight the approved form issued by the
Building and Construction Industry (Portable Long Service Leave) Authority that confirms that the
requirements of the Act have been satisfied. A statutory declaration outlining the cost of the operational
works must be submitted to Council with the lodgement of any application for operational works over the
site.
16. The requirements of the Environmental Protection Amendment Regulation (No. 2) 1999 and Local Law
No. 12, prevents a builder or building contractor carrying out building work on a building site in a way that
makes or causes audible noise to be made from the building work:-
16.1. On a Sunday or public holiday, at any time; or
16.2. On a Saturday or a business day, before 7.00am or after 6.30pm.
A maximum penalty of $1,500 applies to an offence under this legislation.
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 22
NOOSA COUNCIL IDAS Development Application Decision Notice 22 of 24
List of Submitters
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
BF Murphy Murmag Peregian Holdings PO Box 26 NOOSA HEADS QLD 4567
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 23
NOOSA COUNCIL IDAS Development Application Decision Notice 23 of 24
Appeal Rights
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
The following is an extract from the Integrated (6) If an application involves assessment against
Planning Act (Chapter 4). a concurrence agency code, appeal rights for
submitters for the application are not available
Division 8 - Appeals to court relating to against the part of the approval that represents the
development applications concurrence agency’s response for the code.
Appeals by applicants Appeals by advice agency submitters
4.1.27.(1) An applicant for a development application 4.1.29.(1) An advice agency may, within the limits of
may appeal to the court against any of the following- its jurisdiction, appeal to the court about the giving of
(a) the refusal, or the refusal in part, of a a development approval for a development
development application; application if-
(b) a matter stated in a development approval, (a) the development application involves impact
including any condition applying to the assessment; and
development, and the identification of a code (b) the advice agency told the applicant and the
1
under section 3.1.6; assessment manager to treat its response to the
(c) the decision to give a preliminary approval when a application as a submission for an appeal.
development permit was applied for; (2) The appeal must be started within 20 business
(d) the length of a currency period; days after the day the decision notice or negotiated
decision notice is given to the advice agency as a
(e) a deemed refusal. submitter.
(2) An appeal under subsection (1)(a) to (d) must Appeals for matters arising after approval given
be started within 20 business days (the “applicant’s (co-respondents)
appeal period”) after the day the decision notice or
negotiated decision notice is given to the applicant. 4.1.30.(1) For a development approval given for a
development application, a person to whom any of
(3) An appeal under subsection (1)(e) may be the following notices have been given may appeal to
started at any time after the last day a decision on the the court against the decision in the notice-
matter should have been made.
(a) a notice giving a decision on a request for
Appeals by submitters extension of the currency period for an approval;
4.1.28.(1) A submitter for a development application (b) a notice giving a decision on a request to make a
may appeal to the court about- minor change to an approval.
(a) the giving of a development approval, including (2) The appeal must be started within 20 business
any conditions (or lack of conditions) or other days after the day the notice of the decision is given
provisions of the approval; or to the person.
(b) the length of a currency period for the approval. (3) Subsection (1)(a) does not apply if the
approval resulted from a development application
(2) The appeal must be started within 20 business (superseded planning scheme) that was assessed as
days (the “submitters appeal period”) after the day if it were an application under a superseded planning
the decision notice or negotiated decision notice is scheme.
given to the submitter.
(4) Also, a person who has made a request
(3) If a person withdraws a submission before the mentioned in subsection (1) may appeal to the court
application is decided, the person may not appeal the against a deemed refusal of the request.
decision.
(5) An appeal under subsection (4) may be
(4) If an application involves both impact started at any time after the last day the decision on
assessment and code assessment, appeal rights for the matter should have been made.
submitters are available only for the part of the
application involving impact assessment. Division 9 - Appeals to court about other matters
(5) If an application is processed under section Appeals for matters arising after approval given
6.1.28(2), appeal rights for submitters for the (no co-respondents)
application are available only for the aspects of the
development that would have required public 4.1.31.(1) A person to whom any of the following
notification under the repealed Act. notices have been given may appeal to the court
against the decision in the notice-
(a) a notice giving a decision on a request to change
or cancel a condition of a development approval.
1
Section 3.1.6 (Preliminary approval may override local planning
instrument)
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Page 24
NOOSA COUNCIL IDAS Development Application Decision Notice 24 of 24
2
(b) a notice under section 6.1.44 giving a decision to
change or cancel a condition of a development
approval.
(2) The appeal must be started within 20 business
days after the day the notice of the decision is given
to the person.
(3) Also, a person who has made a request
mentioned in subsection (1)(a) may appeal to the
court against a deemed refusal of the request.
(4) An appeal under subsection (3) may be
started at any time after the last day the decision on
the matter should have been made.
Appeals against decisions to change approval
conditions under the repealed Act
4.1.33A.(1) A person who is dissatisfied with a
decision made on an application to change the
conditions attached to an approval given under
section 2.19(3)or section 4.4 of the repealed Act may
appeal to the court against-
(a) the decision; or
(b) a deemed refusal of the application.
(2) An appeal under subsection (1)(a) must be
started within 20 business days after the day notice of
the decision is to be given to the person.
(3) An appeal under subsection (1)(b) may be
started at any time after the last day a decision on the
matter should have been made.
Appeals against local laws
4.1.33B.(1) An applicant who is dissatisfied with a
decision of a local government or the conditions
applied under a local law about the use of premises
or the erection of a building or other structure
permitted by the planning scheme may appeal to the
court against the decision or the conditions applied.
(2) The appeal must be started within 20 business
days after the day notice of the decision is given to
the applicant.
2
Section 6.1.44 (Conditions may be changed or cancelled by
assessment manager or concurrence agency in certain
circumstances)
A c:\docume~1\tblogg\locals~1\temp\bcl technologies\easypdf 5\@bcl@6c06e85a\@[email protected]
Used in these records
05/1917 - SUPERSEDED Compiled Decision Notice [As Published]Related documentApplication case desk ↗
05/1917 - SUPERSEDED Compiled Decision Notice [As Published]Related documentApplication case desk ↗
05/1917 - SUPERSEDED Compiled Decision Notice [As Published]Related documentApplication case desk ↗
About this file
- File size
- 339 KB (small file)
- File type
No other editions are linked here.