Council archive · source document
OPW18-0016_Change Representation · OPW18/0016
Attached to the e-mail Correspondence from Applicant to Suspend Appeal Period under - Sect 75 OPW18/0016.
Version 3 – March 2013
Form 15—Compliance Certificate for building Design or Specification
NOTE This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether
building work complies with the BCA or a provision of the QDC. A building certifier (Class B) can
not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address (include no., street, suburb / locality & postcode)
This section need only be completed if
details of street address and property
26 Dolphin Bay Drive
description are applicable. Sunshine Beach, QLD Postcode 4567
EG. In the case of (standard/generic)
pool design/shell manufacture and/or
Lot & plan details (attach list if necessary)
patio and carport systems this section
may not be applicable.
In which local government area is the land situated?
The description must identify all land the Noosa Council
subject of the application.
The lot & plan details (eg. SP / RP) are
shown on title documents or a rates notice.
If the plan is not registered by title, provide
previous lot and plan details.
2. Description of component/s certified
Clearly describe the extent of work covered by Structural design of proposed new garage
this certificate, e.g. all structural aspects of the
steel roof beams.
This certificate does not apply to the following:
existing structure outside of proposed scope of work as per
reference documentation.
3. Basis of certification
Detail the basis for giving the certificate and the Standards:
extent to which tests, specifications, rules, AS/NZS 1170.0 (2002), AS/NZS 1170.1 (2002), AS/NZS 1170.2 (2011), AS
standards, codes of practice and other 2870 (2011), AS 3600 (2009), AS 3700 (2011), AS 4678 (2002)
publications, were relied upon.
Loadings:
Roof Live Load – 3.0kPa
Driveway / Carport – 2.5kPa / 9kN
Wind Loading – N3
Geotechnical Conditions:
Footings have been designed in accordance with site investigation numbered
17/1057 by Global Testing
As per Noosa Council Decision Notice (Application Number
OPW18/0016), the following have been satisfied in the design covered in
this certificate:
a. have the capacity to cater for the expected stormwater flows in
accordance with Council’s Planning Scheme Policy PSP 5
b. will not result in additional ponding of stormwater on the subject
site, the road reserve or any adjoining property
c. will not result in any scour or damage to the subject site or the
adjoining reserve.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
OPW18-0016_Change Representation.pdfRelated documentApplication case desk ↗
About this file
- File size
- 251 KB (small file)
- File type
No other editions are linked here.