                 Your Mates Bowlsy Pty Ltd                                                                             Reference: #1859d1-B
                 Your Mates Bowls Pub                                                                                    Date: 6 March 2025
                 Noise Impact Assessment

                 2025 to determine the existing noise impacts. Noise measurements were taken using a Nor139
                 sound level meter at the locations illustrated in the figure below. Noise survey instrumentation
                 information is provided in Table 3.




                                                                              A




                                                           B                        C




                    Measurement Location



                                      Figure 5. Attended measurement locations of mechanical plant noise



                 Measured noise levels from the mechanical plant assessment are presented below.

                                                     Table 8. Measured mechanical plant noise levels

                  Meas.              Description /        Duration         Level, dBA
                                                                                                              Comments
                   No.                Location           (min:sec)   Leq      L90       Lmin
                                     Location A –
                                 Directly below
                                                                                                Plant noise clearly audible. Continuous
                     1        rooftop mechanical           1:00      57       57        56
                                                                                                             noise source.
                               plant, 3m from the
                                  noise source
                                     Location B –
                                                                                                Plant noise clearly audible. Continuous
                     2           1m from Patton            1:00      68       68        68
                                                                                                             noise source.
                                refrigeration unit
                              Location C – At the
                                                                                               Noise from refrigeration plant and kitchen
                              eastern boundary of
                     3                                     1:00      58       58        58      exhaust fan audible. Continuous noise
                              the site, adjacent to
                                                                                                                source.
                                11 Opal Street




                 Live It Acoustics                                                                                                  Page 13

Document Set ID: 23656872
Version: 1, Version Date: 26/03/2025
Log in to download the original file

Compiled Reference Document - 51995.1611.04 (As Published).pdf · 4.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.