Skip to the record
Accept no imitations.

Original source · versioned page text

Compiled Reference Document - 51995.1611.04 (As Published)

of 74

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                 Your Mates Bowlsy Pty Ltd                                                                         Reference: #1859d1-B
                 Your Mates Bowls Pub                                                                                Date: 6 March 2025
                 Noise Impact Assessment

                 The children were modelled as an area source 0.9 meters above ground level and was calculated
                 to have a total SWL of 87dB. For the purposes of a conservative assessment, it is also assumed
                 that the LAeq,adj,15min is equivalent to an LAeq,adj,1hr.

                 The noise sources of the children playing have been modelled as an area source to be operating
                 for 75% of the time during the hours of 10:00 AM – 10:00 PM.

                 Results of the noise prediction model are detailed in the below section.

                 4.8 Results and Discussion
                 The predicted noise levels at the SRs are provided as follows. The results presented are the
                 impacts at the most affected point of each SR. Noise levels are only shown for the closest SRs to
                 the site, as they are considered to be the most affected. Should compliance be achieved at these
                 locations, compliance is also predicted to be achieved at all other SRs within the wider area due
                 to distance separation and shielding from buildings or structures.

                 4.8.1 All Operational Noise Sources
                 To provide the expected worse-case impacts, an assessment of all operational noise sources
                 associated with the development was conducted. This assessment assumes use of all spaces are
                 occurring simultaneously, which may not occur in practice. Hence, the assessment of noise
                 impacts is considered conservative.

                 The predicted noise levels at the nearest SRs are detailed in Table 13, with noise contour maps
                 presented in Appendix D – Noise Contour Maps.

                                     Table 12. Predicted noise levels – All operational noise sources – LAeq
                                                       Predicted noise levels at receptor façade in dBA (LAeq,adj,1hr
                                                                                                                           Compliance
            Sensitive Receptor Reference                                          Evening                 Night
                                               Floor         Day                                                          Day / Evening /
                  (Refer to Table 2)                                             (6:00PM –            (10:00PM –
                                                       (7:00AM –6:00PM)                                                       Night
                                                                                 10:00PM)               7:00AM)
                                                GF             44                   N/A                   N/A             YES / N/A / N/A
                    1 (Commercial)
                                                F1             45                   N/A                   N/A             YES / N/A / N/A
                    2 (Residential)             GF             40                    37                   25             YES / YES / YES
                                                GF             41                    40                   34             YES / YES / YES
                    3 (Residential)
                                                F1             42                    42                   35             YES / YES / YES
                    4 (Residential)             GF             42                    42                   27             YES / YES / YES
                    5 (Commercial)              GF             46                   N/A                   N/A             YES / N/A / N/A
                    6 (Commercial)              GF             36                   N/A                   N/A             YES / N/A / N/A
               Noise limit Residence, LAeq,adj,T               42                    42                   35
              Noise limit Commercial, LAeq,adj,T               52                   N/A                   N/A



                 Compliance with the established noise criteria is predicted, provided the recommendations in
                 Section 5 are implemented in full.




                 Live It Acoustics                                                                                             Page 18

Document Set ID: 23656872
Version: 1, Version Date: 26/03/2025
Log in to download the original file

Compiled Reference Document - 51995.1611.04 (As Published).pdf · 4.2 MB (large file)