Council archive · source document
Letter from Alan & Linda Thomas - Crossover from Leslie Drive · OPW11/0119
^,CRL^ CORRESP O EN
ND CE
11 May 2011
Alan and Linda Thomas
Po box 1420
Noosa Heads Q 4567
Attention: Chris Gibberd
Senior Development Engineer
Sunshine Coast Shire Council
Locked Bag 72
Sunshine Coast Mail Centre, Q 4560
Dear Chris,
RE: 7 Moonare Crescent, Noosa Heads - Proposed Crossover from Leslie Drive, Noosa Heads
Reference is made to our previous application for two crossovers from Moonare Crescent to the
above property and to our subsequent application to delete the crossover on the left hand side of
the property and relocate it to Leslie Drive.
Reference is also made to your letter of 15 April 2011 requesting further information regarding the
proposed crossover from Leslie Drive.
We appreciate that Leslie Drive is a busy collector road and that safety is paramount. If a crossover
from Leslie Drive is approved it will not be used on a daily basis. This crossover will be used to access
the wider back yard for maintenance purposes and to access a second garage located on the ground
floor of the residence. This second garage will mainly be used for storage of a vehicle which will not
be driven on a daily basis. Access to the property from Leslie Drive will therefore be infrequent. The
main access / garage for the property that will be used on a daily basis will be the one located on
Moonare Crescent.
We feel that the Leslie Drive crossover is a safer option than the second one shown on the site plan
from Moonare Crescent given the narrow allotment frontage, and shape of the block.
If the Leslie Drive crossover is approved, the second cross over from Moonare Crescent will be
deleted.
We hope that you will take these matters into consideration when you make your decision.
We thank you for your consideration.
C ounter
Yours Faithfull,
1.3 MAY
^^ / /L(•Y9r L^ .7
Alan & Linda Thomas.
Encl. Site plans
Box: ^?^ 52
........ .^c:01. ._
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
5ustainabiiity Requirements
- Provide Greenhouse-efficient hot water systems
- Provide AAA-rated shower roses with min 3-star
water Efficiency and Standards rating z
- Provide dual-flush (6/3 litre) toilets with min 4-star
water Efficiency and Standards Rating
Provide tapware with min. 3-star water Efficency
Labelling and Standards rating for taps Serving:
(a) Laundry tubs i
(b) Kitchen sinks i
u-I A DEVE_LOPNiENT APPLICATION 2W10/10
(c) Basins
N0. I DESCRIPTION DATE
Provide water pressure-limiting devices
(where water pre55ure exceeds, 500 kilopascals)
- &ner qy Efficient Lighting 35e sqm min required (50%)
Max. 1.5m high mas. blk wrk
CONST TO BE IN ACCORD WITH THE OLD BUILDING ACT 1q is,-lgg9 6
retaining wall to engineers THE STANDARD BUILDING REGULATION 1gg3 AND SHALL COMP-,Y NiwTH
details - subject to Site levels ALL LOCAL AUTHORITY REGJLATIONS AND REQUIREMENTS
-IMBER SIZES ! COH•:NECTION DETAIL NOT 5HONBN ARE TO BE IN
ACCORD WITH A51684-111gq RESIDENTIAL TIMBER-FRAMED
CONSTRUCTION MANUAL FOR 4WND SFEEG' NOMrNATED BELOW
Gross over to be in DO NOT SCALE
accordance with the VERIFY ALL DIMENSIONS AND LEVELS ON SITE BEFORE STARTING Vii,-' '
local authority
regulations
SITE NOTES
GENERAL
FIRST FLOOR
SITE LEVELS AND FINISHED FLOOR LEVEL ARE TO BE VERIFIED BY
F.F.L. = 8360 THE BUILDER BEFORE STARTING iNORK
ALL GUT 4 FILLED GARTH EMBANKMENTS ARE TO BE GRASSED
UNLESS UNLESS NOTED OTHERWISE.
SITE DRAINAGE
FOR SLOPING SITES DIVERT SURFACE MATER FROM UPH'LL SIDE
AWAY FROM BUILDING
PROVIDE FALLS TO FINIS. GROJND SURFACE TO PREVENT WATER
PONDIN6 AT ANY POINT IN THE v CINi'Y CF THE BUILDING OR ON INC
C_1-Ml 1CN 30UNDARY OF AG OWING ALLC 71-TE1' TS
Road
ROOF DRAINAGE
DISCHARGE DOWN PIPES TO K. AND C./RY TANK
PLACE DOWN PIPES GENERALLY AS SHOWN ON SHEETS 02/03
YVASTE DISPOSAL
DISCHARGE WASTE WATER TO COUNCIL 5EVIER,
PROPOSED RESIDENCE
Max. 2.2m high mas blk wrk FOR A. $ L. THOMAS
retaining wall to encneers
details, - subject to1site levels, AT LOT 25q MOONARE GRES
NOOSA HEADS
All cut i fill banters to
be at 1 in 3 ma \slope. MEMBER
BUILDING DESIGNERS
RA ASSOC. OF QLD INC.
Licenced under
the QBSA Act
Lic No, 1180286
Site Plan Telephone 61 7 49288011
Facsimile 61 7 49266579
57YLE- QUAL/TY• INNO VA 770N
Development Coun 1:200 R.Q.D. E-mail mailbox@rufusdesigngroup com
Lot Number 259
Reg./survey Plan Number : RP1-7cM-12 DESIGNED J.P. WIND ,- PROJECT NUMBER
13 MAY 2011 Parish : wEYBA
SPEED V
County : March DRAM : ,N''9 . ° . J 100522 -- 01
Area :
PLAN
Tewantin
71135gm
CHKO €T.P SIZE: A3 SHEET
•^
01 OF 10 SHEETS
-- - REVIT FILE : A
SCALE : As, Indicated 100622.rvt REV•
PRINT PATE :
Used in these records
Letter from Alan & Linda Thomas - Crossover from Leslie DriveRelated documentApplication case desk ↗
About this file
- File size
- 1.5 MB (small file)
- File type
No other editions are linked here.