Council archive · source document
OPW15/0076 Application for non-standard driveway
catchpit, manhote and pipetine locations
drainage details (if applicable)
cross road drainage culverts (if appticabte)
concrete footpaths and cycle paths
iocation and details for access points, ramps and invert crossings
changes in surfacing material.
Applications for operational work involving stormwater drainage
Drawings showing:
existing and proposed contours
drainage locations, diameters and class of pipe, open drains and
easements
manhole location, chainage and offset or coordinates and inlet and outlet
invert levels
inlet pit locations, chainage and offset or coordinates and invert and kerb
levels,
Cl Confirmed
Cy Not applicable
Applications for operational work involving water reticulation
Drawings showing:
kerb fines or edge of pavement where kerb is not constructed
location and levels of other utility services where affected by water
reticulation works
pipe diameter, type of pipe and pipe alignment
water main alignments
water supply pump station details (if applicable)
minor reservoir details (if applicable)
conduits
location of valves and fire hydrants
location of house connections (if applicabte)
location of bench marks and reference pegs.
L Confirmed
C Not applicable
Applications for operational work involving sewerage reticulation
Drawings showing:
location of all existing and proposed services
location of all existing and proposed sewer tines and manhole locations
location of all house connection branches
kerb lines or edge of pavement where kerb is not constructed
chainages
design sewer invert levels
design top of manhole levels
type of manhole and manhole cover
pipe diameter, type of pipe and pipe alignment
location of house connections (if applicable)
sewer pump station details (if applicable).
oO Confirmed
oO Not applicable
Applications for operational work involving street lighting
Drawings showing:
location of all light poles and service conduits
location of all other cross road conduits
type of wattage and lighting
any traffic calming devices
additional plans for roundabouts and major roads {if applicable)
details of any variations to normal alignment
C] Confirmed
CI] Not applicable
IDAS form 6—Building or operational work assessable
against a planning scheme
Version 3.0—-1 July 2013
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
OPW15/0076 Application for non-standard drivewayRelated documentApplication case desk ↗
About this file
- File size
- 785 KB (small file)
- File type
No other editions are linked here.