Attachment 1 - Amended Proposal Plans

of 9

Page text shows just the words. Original shows the document exactly as it was published.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
    Notes for Construction & Maintenance of Timber Decks:

    Builder to adhere to BCA Part 3.10.6 & to Manufactures Engineers specifications or industry standards at all times &               Timber Queensland recommend that all timber has a moisture content of 15%
    Owners to follow manufactures details for maintenance & cleaning of deck                                                           Decking boards to be fixed with 2/nails or screws & staggered or offset along the joists. Holes at ends of boards to be
    All timber posts to be naturally durable Class 1 or 2 above ground or softwoods H3 treated if supported on bracket if in           drilled holes to be 80% of nail diameter & 12mm from ends of boards. Nails & screws to finish flush with top of boards (Not
    ground to be H5 Treated soft or hardwood.                                                                                          Punched). Nails or screws to be hot dipped galvanized or stainless steel. Stainless Steel to be used within 900 mm of
    Recommend brackets or supports be used & Bitumen paint be applied to the top 200 mm of bracket in the concrete.                    pools
    Posts to have a Minimum 75 mm clearance from the base of the post to footing or slab & post to be 10 mm above cross                All Framing Anchors, Fixing Plates, Nailing Plates, Joist hangers to be Galvanised Minimum or Stainless Steel where
    member of bracket. End grain of post to be sealed prior to erecting.                                                               Construction within 2.0 km radius of open coastal areas
    Top of concrete pad footing to be mounded to fall away from support to prevent water from ponding                                  Ends of boards to be slightly undercut at joints. Gaps between decking boards to be min 3 mm to 5 mm
    Bearers, Hardwood to be H3 treated if less than 400 mm above ground H4 for touching ground H5 for in ground.                       (Check with supplier Gaps range with different Types of timbers)
    Joists as bearers depending on ground clearance. Joists to have Malthoid strip or an, approved proprietary joist protection        Decking boards to be fully sealed (Oiled, Stained, Painted etc.) prior to fixing.
    system, fixed to top of joists. Softwood & Engineered manufactured timbers bearers & joists to be H3 min treated at all            Recommend a light coloured sealer, with UV protection and a fungicide to be used
    times. Approved connectors be used for treated timbers & location.
    Recommend hot dip galvanized or stainless steel connectors & fixings be used at all times. Especially where inspections            Maintenance & inspection of deck by Owner is to be carried out regularly
    are not possible deck is to close to ground or decking to be screwed in place to allow for easy removal to inspect sub-floor       Sweep or blow, leaf or other debris off deck. Hosing or use of water to be avoided. Keep the gaps between decking boards
    for any issues                                                                                                                     clear of dirt & debris.
                                                                                                                                       Reseal decking boards when required by manufactures recommendations
                                                                                                                                       Inspect all connections for corrosion or movement regularly (Twice Yearly)
                                                                                                                                       Pot plants to be on stands with a drip tray underneath & moved around regularly to prevent uneven weathering of the deck
                                                                               600                                                     Accolade Building Designs recommends that Builder & Home Owners read Domestic Deck Design Guide                               600
                                                                                                                                       Available on line www.timber.net.au


                                                                                                                                                                                                                                                                                  Custom Orb Roof sheets
                                                                                                                                                                                                                                                                                  Fixed to Manufactures details for N3 Wind Classification
Approved type roof Trusses to Manufacturers @ 900 Ctrs                                                                                                 5°                                                                                                                         Approved type roof battens @ 900 Ctrs
30 mm Galv looped strap or 2/Framing anchors (Triple Grips                                                                                                                                                                                                                        Fixed to Manufacturers details for N3 Wind Classification
4/30 mm nails per leg)
                                                                                                                                                                                                                                                                                  Approved type metal gutter guard
                                                                                                                                                                                                                                                                                  as required by BAL



                                                                                                                                                                                                                                                                                  Colorbond metal Fascia & Gutter
RB1: Roof beam 2/M12 bolts to posts
Manufactured beams to be protected                                                                                                                                                                                                                                                Approved type 6 mm FC Sheet to Soffit
from weather as per Manufacturers details and BAL Requirements                                                                                                                                                                                                                    Top plates 2/90x45 MGP12


C2: Hardwood Timber Posts Approved type timber for BAL Rating




                                                                                                                                                                                                                        Ceiling Hgt 2700
                                                                                                                                                  W3                                                   W4                                        W5




                                                                                                                                                                                                                                                      2400
                                                                                                                                                                                                                                                                                  Tie-down 12 mm rods from subfloor to top plates
Hardwood Timber decking boards to joists                                                                                                                                                                                                                                          Studs 90x35 MGP 12 @ 450 Ctrs
Approved type timber for BAL Rating
                                                                                                                                                                                                                                                                                  Cladding to comply with BAL supplied by
                                                                                                                                                                                                                                                                                  an Approved Qualified person
J2: Hardwood Timber Joists @ 450 Ctrs 1/framing anchor 4/30 mm nails per leg
Joist protector strips to top of Joists Approved type timber for BAL Rating                                                                                                                                                                                                       Bottom Plates 90x45 MGP12

                                                                                                                                                                                                                                                                                  J1: Joists at 450 Ctrs 1/Framing anchor 4/30 mm nails peer leg
                                                                                                                                                                                                                                                                                  @ Joists under outer walls
                                                                                          Less than 1000




C2: Hardwood Timber Bearers Approved type timber for BAL Rating
2/M12 bolts to Posts
                                                                                                                                                                                                                                                                                  B1: Bearers 2/M12 bolts to C1




                                                                                                                                                                                             Min 400
Pryda PSQ600100/12
Post support bracket 2/M12 bolts to posts
                                                                                                                                                                                                                                                                                  C1: Galv SHS posts to Engineers details
N12 Cranked through support 1000 mm in length
                                                                                                                                                                                                                                                                                  Bitumen paint to Posts min top 200 mm in concrete
                                                                                                                                                                                                                                                                                  Concrete pad footings to Engineers details




                                                                                                                          Ground Under Floor & Decks to be have ALL vegetation removed and be Graded so Groundwater Does Not Pond Under Floors



                                                                                                                                                                          Section A
                                                                                                                                                               A            1 : 50
                                                                                                                                                                                                                                                                                                Engineers Details to Take
                                                                                                                                                                                                                                                                                                Precedence Over Shown Details

Client: Scott Stewart                                            Address: 797 Ringtail Creek Rd. Pomona                            Noosa Shire Council                                                                                                Mobile: 0407 693 018        Date     2/02/2022 11:25:21 AM
                                                                                                                                                                            ACCOLADE Building Designs                                                                             Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on RP 213871                                      Site Area : 34073 m²                          Wind Classification N3                                                     Proprietor: Steven Horn                                  Email: [email protected]
                                                                                                                                                                                                                                                                                                  Project Number                         0521SS
Proposed Residence SHS & Timber Posts , Timber Framed, Sheet Roof                                                                                                                      QBSA Lic. 54806                                         Issue Date:           02 - FEBRUARY -2022          Scale 1 : 50          Sheet No. 4          of 9
Log in to download the original file

Attachment 1 - Amended Proposal Plans.pdf · 271 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.