Original source · versioned page text
Planning Report - Code MCU - 25-27 Toolar St Tewantin.pdf
e) allow for space and that uncovered visitor parking, or At ground level, the outdoor
landscaping to be provided swimming terrace in the open space is
between buildings including pools protruding no more than 1 provided with a roof giving
adequate area at ground metre above the ground level, can weather protection and to facilitate
level for landscaping with be as close as 2 metres from the use of outdoor spaces consistent
trees, shrubs, outdoor living front boundary. with residents’ enjoyment of the
and utilities; subtropical climate of the Noosa
f) be consistent with the AO12.3 Region in an outdoor space. The
predominant character of the Relocatable homes are set back not roof of the ground floor terrace to
surrounding area; and less than: Units 5 & 8 result in a setback to
g) protect the natural character the rear boundary of 2.3m, while
a) (a) 6 metres from a Units 6 & 7 are setback
and avoid adverse impacts road frontage;
on ecologically important approximately 3.3m. This
(b) 1.5 metres from any structure is located at the ground
areas such as national parks,
other site boundary; and level and is unlikely to result in
waterways and wetlands. (c) 3 metres from an internal adverse visual amenity,
road obstruction of views or result in
AO12.4 excessive building bulk.
Buildings and structures on
premises with frontage to the Noosa Side
River system are set back not less The overall height of the buildings
than 10 metres from mean high is no greater than 7.5m. The
water spring as shown in Figure ground floor side setbacks meet
AP3-15A. the minimum 1.5m to the wall with
minor encroachment of window
Alternative provision to the QDC hoods by up to 0.6m.
Front
Setback to the wall on the road
frontage meets the minimum
requirement at 6.5m. Minor
encroachments include the roof
overhang on the upper level, the
upper level balcony, partition wall,
and window hoods. The minimum
setback to the outermost
projection is 3.6m to the overhang
of the upper level roof.
Design
Streetscape AO14.1 The proposed building design
PO14 Development provides visual makes a positive contribution to
Development: interest to the street and the streetscape. The existing
surrounding areas through: dwellings are visibly aging and are
a) contributes positively to the in need of significant upgrading.
locality; a) highlighting individual The proposed multiple dwelling
b) addresses and enhances the dwellings and land uses; design pays tribute to the old
streetscape by incorporating b) an asymmetrical design buildings of Tewantin with the
articulation and individual presentation to the street; timber and tin character and post
design elements that add c) offsetting or staggering war design.
visual interest to the dwellings to provide variation The built form is softened by the
development; in the frontage; significant landscaping and
d) varying the roof form setback to the courtyard fences on
c) has a form and architectural Toolar Street. The design is not
scale that does not dominate out of character or scale with
AO14.2
the streetscape or the surrounding development in the
Buildings have the main entrance
surrounding properties; area.
easily recognisable from the street
d) does not detract from the and include design elements in the The design is visually appealing
visual amenity of adjoining front façade such as verandahs, and provides interest in the façade
properties through the impact external stairs, awning or shade design. The development is
on views, access to sunlight or structures and window openings. comprised of 3 smaller buildings
overlooking; in a landscaped setting rather
AO14.3 than a single block of 8 dwellings.
e) takes the form of small Buildings and structures are
separate buildings, rather than designed to:
large single bulky
development; and
Material Change of Use – Multiple Dwelling (Code Assessment)
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Planning Report - Code MCU - 25-27 Toolar St Tewantin.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.