Original source · versioned page text
App E - Amended Development Plans
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
XXX INDICATES DEPTH OF FILL
RENDERED BLOCKWORK
RETAINING WALL 800MM HIGH
Existing
REFER TO LANDSCAPING Lot 2 Lot 5
Lot 2 Highset
SP129049 House RP72243
SP129048 Approximate House
Connection Plotted
From Statutory or POOL EXCAVATION APPROX. .900
Supplied Records
Invert Level Not Available
No 22.943 Stake Found
Depth Not Available
Mk 358°33' No
Block Fence
Found 1.66 Mk
1.72
1.79 1.64 1.69
Timber Fence
1.90
6000 Found
7
Pipe
1.5
13
0
1.7
14
9
1.6
Sewer M/H S S
12 S S S
75 S S S
Not Located S S
S 1.
S S
S S S
SS
S S S S S DRAIN
Approximate Sewer Line Location (See note)
8
Timber Fence on Existing Block Retaining Wall (Approx. 0.6m Rise)
1.5
S
0.860
DRAIN
9
1.5
0
0.850
1.6
8
1.5
0.860
S
10
89°58' Weldmesh Fence
Pipe
15 800MM RENDERED BLOCKWORK
11
1.71
RETAINING WALL REFER TO LANDSCAPING
DRAIN DRAIN
9 8
2
0.820
1.6
2
0.930
1.6
1.58
7
1
1.5
0.820
2
1.6
Pipe
Existing
Highset
269°58'
PROPOSED
0.710
4
House
1.7
RESIDENCE 0.700
1.78
28.777
1200MM BLOCK UP BASE WAFFLE SLAB
3
1.7
310MM PROPOSED Existing
1.75
Lot 0
9
1.57
RESIDENCE
29.34
2
1.5
1.6
PAD: 2.440 DRAIN
Unit
SP307693 0.850 F.F.L.: 2.750 DRAIN
WAFFLE SLAB 0.820 Complex
310MM
DRAIN
9
W/A
1.5
DRAIN
1.78 0.850
PAD: 2.440 6
0.660
F.F.L.: 2.750 Lot 0
6
1.5
Existing
BUP4964
Highset 5
House
1.61
6
1.5
1.69
1.65
8
1.5
8
2
1.6
1.6
600-800MM RENDERED BLOCKWORK
Weldmesh Fence
600-800MM RENDERED BLOCKWORK RETAINING WALL REFER TO LANDSCAPING
0
1.7
1
RETAINING WALL REFER TO LANDSCAPING 1.7
1.71
8
1.55
1.6
3 Garden Bed
0
No
1.6
2 1.6 4 Mk
Peg Flag Pole
1.69
3 1.6
Property Pole 7 Found
Post
Found
2
22.963
1.6
1.67 W Meter
Field 9
1.6
400-600MM RENDERED BLOCKWORK
0
1
1.61
1.71
1.7
177°08'30"
1.70
Gully VV RETAINING WALL REFER TO LANDSCAPING
W Meter
1
Valve x 2 WW
1.6
Telstra Concrete Driveway
Meter
1.54
400-600MM RENDERED BLOCKWORK
2
x2 9
1.6
RETAINING WALL REFER TO LANDSCAPING Concrete Telstra 1.54
1.64
Driveway 1.53 1.54 1.54
1.54 1.39
Concrete Access 1.39
1.5
1.56 1.40 Roofwater
1.41 TBM 1 Nail in Kerb
3
1.43
1.42 Outlet IL1.41 RL 1.539
George Street
Roofwater TBM 2 Nail in Kerb
Outlet x 2 RL1.568
IL1.43
NOTES: DRAWING TITLE: DESIGN: PRODUCT CODE: OWNER:
EATHWORKS PLAN GEORGE STREET 20 WILLIAMS DEVELOPMENTS
0 1 2 3m Do NOT scale this drawing. FACADE: CEILING: (No 9) LOT 8 GEORGE ST,
20/03/2026 2:12:57 PM
All written dimensions take precedence
SCALE 1 : 200 (A3) over scaled dimension. If in doubt, ASK. GEORGE STREET 27G, 27F L/R NOOSAVILLE, QLD
Power Pole JOB N°: 760230 & 760231 PERMIT N°: TBC
209 Robina Town Centre Dr, Robina, QLD, 4226 © COPYRIGHT
QBCC Licence N°: 40992 WIND SPEED: 41.11m/s MASTER ISSUED: TBC
NSW Contractor's Licence N°: 36654C Metricon homes owns copyright
ACN: 005 149 137 in this drawing. DRAWN: 0TS CHECKED:
Unauthorised use, reproduction
SHEET:
Tel: 1300 786 773
www.metriconhomes.com.au or adaption is forbidden and will
be prosecuted. WORKING DRAWINGS 21/19
SPEC: NATIONAL 01/04/2023 DATE: 20/03/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (App E - Amended Development Plans.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.