Original source · versioned page text
Change to Jetty OPW18-0150 - Appendix B
Attached to the e-mail Change Operational Works Application - OPW18/0150.01 - 21 Wesley Court Noosa Heads.
Department of Housing and Public Works
Form 15—Compliance certificate
for building design or
specification Version 4 – July 2017
NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work
complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B)
can not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address (include no., street, suburb/locality and postcode)
This section need only be 21 Wesley Court
completed if details of street
address and property description Noosa Heads QLD Postcode 4567
are applicable.
E.g. in the case of Lot and plan details (attach list if necessary)
(standard/generic) pool design/shell Lot 42 N21843
manufacture and/or patio and
carport systems this section may In which local government area is the land situated?
not be applicable. Noosa Council
The description must identify all
land the subject of the application.
The lot and plan details (e.g.
SP/RP) are shown on title
documents or a rates notice.
If the plan is not registered by title,
provide previous lot and plan
details.
2. Description of New structural frames and seabed anchors to support floating boat fender,
component/s certified kayak double step and jetski dock pontoons on existing timber jetty.
Clearly describe the extent of work
covered by this certificate, e.g. all Excludes:
structural aspects of the steel roof
beams.
Existing timber jetty: piles, bearers, joists, decking, stairs and railing.
Methods of construction including temporary bracing and propping
Existing structures including the revetment wall and proprietary pontoon devices
Jetty is to be built independently of all existing structures on the site
3. Basis of certification
AS1170 SAA Loading Code
Detail the basis for giving the
certificate and the extent to which AS1720 Timber Structures
tests, specifications, rules,
standards, codes of practice and other AS2159 Piling Code
publications, were relied upon.
AS1664 Aluminium Structures
AS4997 Guidelines for the Design of Maritime Structures
The Noosa Plan – Division 21 Watercourses Works Code
The Coastal Protection and Management Regulation 2017: relevant Parts and
Schedule 3
4. Reference documentation Long View Consulting Engineers Drawings 20.003 21 Wesley Ct [S001 – S004]
Clearly identify any relevant
documentation, e.g. numbered
– C2 (Construction Issue)
structural engineering plans.
LOCAL GOVERNMENT USE ONLY
Date received Reference Number/s
See the original
The page text is free to read. Viewing or downloading an original file needs an account.