Council archive · source document
OPW16/0105 - Approved Plans
Plans and drawings: the text below has words only, no drawings.
Revision Description Date
. . .
. . .
. . .
Issue:
DEBUILD T/A
SCG
ABN 40 098 481 899
-
NOOSA COUNCIL
Title: Drive Way Plan
APPROVED PLAN Project Lot 110(#29) McAnally Drive
OPW16/0105 1 JUL 2016 Sunshine Beach
Rev.
Date: Sept 2015 Drg No. 25335 -DR1 .
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 3 pages
Page 2
Revision Description Date
. . .
. . .
. . .
Issue:
DEBUILD T/A
SCG
ABN 40 098 481 899
-
NOOSA COUNCIL
APPROVED PLAN Title: Longitudinal Drive Way Sections
Project Lot 110(#29) McAnally Drive
OPW16/0105 1 JUL 2016 Sunshine Beach
Rev.
Date: Sept 2015 Drg No. 25335 -DR2 .
Page 3
Revision Description Date
. . .
. . .
. . .
Issue:
DEBUILD T/A
SCG
ABN 40 098 481 899
-
NOOSA COUNCIL
Title: Site Earth Works
APPROVED PLAN
Project Lot 110(#29) McAnally Drive
OPW16/0105 1 JUL 2016 Sunshine Beach
Rev.
Date: Sept 2015 Drg No. 25335 -OW1 .
Page 4
-
NOOSA COUNCIL
APPROVED PLAN
OPW16/0105 1 JUL 2016
[OCR of page images]
2000min
itle
Hot Dip Galvanised Kerb
adaptor to match kerb
/ profile
Boundary
|
450
200
__7omin 75min
A
——
RAIN HEAD
W/ OPEN TOP
\ 125 x 75 x 6mm Galvanised
MS section
Notes:
Connection fitting
refer Detail ’A’
|
75min
#100
WX :'i GY
N
N
N
N
Ly Hot d
A fitting
DETAIL A
pipes
morta
RL 63.10 AHD
GARAGE
FOR CONTINUATION REFER GROUND oun
SECTION A — A
ip MS connection
or approved equivalent.
to sealed with silicone or
r into fittings.
TYPICAL CROSS SECTION OF STORMWATER TO
NOT TO SCALE
PROVIDE 200mm WIDE
LINEAL DRAIN CHANNEL WITH
HEAVY DUTY, TRAFFICABLE
GRATE
DRIVEWAY
vos
=| |
| cette || Uf
non |
/|
POOL ABOVE i!
B
USE SEALED
SYSTEM AND
TO OVER TANK
INLET SCREE!
ASEMENT_ INSERT
WET
RISE
N
_—
a
EN Pa
8 \ ye
=
DS RL
1
i
PD
66.10 AHD VOS
_
a A\
WE
UN Ss
MS section
KERB
PARKING.
1. UPVC pipe to be 100mm heavy duty DWV
class SN6
2. All steel works to be hot dip galvanised
3. All joints on PVC pipe to be sealed with
solvent weld cement (type N or P), or
rubber ring joint.
——
——
=
S
\CAUNDR
——
=
250
Fitting for connection of 4100
uPVC pipe to 125 x 75 x 6mm
some
I~
990
RAIN WATER HEAD DETAIL
SCALE: 1:10
a WALL
3 9100
o100-”
USE GUTTER
PROFILE LARGE
NOOSA COUNCIL
APPROVED PLAN
OPW16/0105 1 JUL 2016
GARDEN
BELOW
PROPOSED POOL
\pex POSITION ea
~a_ USPIT TO FLAT
ROOF BELOW
#90 TO GROUND.
#90 WITH
GUTTER
USE GUTTER PROFILE LARGE
TERRACE
RL 65.75 AHD VOS
GARDEN
—<%
Re
©
b
eb
, yi
outoofid
| gurpofia Oe 1
\
PROVIDE 10,000 LITRE ROOF WATER HARVESTING TANK AND RE-USE RAINWATER FOR IRRIGATION AND POOL TOP UP
GROUND PLAN
91004 Lo150
SPREADER TO pp
ROOF BELOW
NOTE:
FOR ALL GUTTER PROFILE TYPES:
1. ENSURE THAT THE GUTTER WEIR (FACING AWAY FROM
THE BUILDING) IS 25mm BELOW THE TOP OF THE
MOUNTED SHEET.
2. ENSURE THAT GUTTER WIDTH IS ALWAYS MINIMUM
40mm LARGER THAN THE DP DIAMETER. FOR 990
DP THE GUTTER SHALL BE 130mm WIDE. ROOF PLAN
#100 TO KERB & CHANNEL _
AS PER DETAIL oT aa
=
a
Lo =
A —
aa
a
ae =
_ Sune
=
ceo" ©
DRIVEWAY BELOW >
DRIVEWAY BELOW t
= |
SE o
xt
XK \ \\
ZA \\ \ _—
AA \\\\\\ = =
a
& -_ SB! \\ er =
oS “Vie fF m
S
cf ——— |
ENTRY \ — _ | PARKING BELOW
— z SUN DECK |
& /
5 300mm == RL 65.45 AHD VOS I |
g |
e fe
5 8
FAMILY g | | o
50} /
ele | B
RL 65.80 AHD VOS gS / Ir 4
g
[=
3 79100 [$* KR
rau _ [2 REFER_TO_ BASEMENT /S sus ROCK RE Faneuil
— a] INSERP P6R- Is
g CONTINUATION fe |
é
TERRACE |
L655 AHO vos |
\ x OPI
=e Sa aso tt — —— —__ __ __________________ —L59.800
hi Q=18.5L/sec
Lssxsoo I 2#0100 TO KERB & CHANNEL
450sq GRATED Lsi62.250
FIELD INLET iL61.500 AS PER DETAIL
TYPE POLY
9150
DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
[Amd Description Date
Issue Notes Date
For Development Approval
For Building Approval
For Tender xX (01-12-15
For Construction xX 01-12-15
IAs Constructed
H Hydraulic
Va
CONTACT: Reinhold Koenning MiEAust RPEQ No 7023
Moffat Beach, QLD, 4551 AHSCA
email: [email protected]
PH: (07) 5491 4333 FX: (07) 5491 4233
CLIENT :
B & R BENSON
ARCHITECT :
iS CHRIS CLOUT DESIGN J
(PRoecT: 29 McANALLY DRIVE Y
SUNSHINE BEACH
DRAWING TITLE:
STORMWATER
DRAINAGE
Design| RH. checked] h [Date |O01—12—15 | Dwg. No. AMD.
\ SCALE: 1: 100 on At u.N.o.| 2 Of 4 3078-2 J
RPD:— LOT 110 RP 81810
Used in these records
OPW16/0105 - Approved Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.5 MB (small file)
- File type