REFERENCE DOCUMENT
      EXE25/0009
   NOOSA COUNCIL
    28 MARCH 2025


[OCR of page images]
 

NOTES
GENERAL
1. Wind Classification N3

2. All work to conform to the current Building Code of
Australia- Class 1 & with AS1684.2 Residential Timber
Framed Construction-N4 as applicable to the work.

3. The Builder shall check all dimensions, levels& details
before excavation, construction & ordering. Report
discrepancies to designer.

4. Do not scale drawings.

5. The drawings and specifications shall be considered es 7

complementary, and any work and/or materials absent ia eo
from one but present or implied in the other shall be | Ss
furnished as if they were present in both. ee

 

6. Drawings shall be read in conjunction with consultants
drawings.

7. All work, materials & associated fixing methods shall
conform to respective manufacturer's specifications & |
Australian Standards as applicable to the work.

8. Construction shall not proceed before approval in writing
has been received from both the Building Certifier & Council
as applicable.

9. It is the obligation of the contractor and / or plumbing
contractor to survey all existing services prior to
construction.

10. No footing, or wall to encroach the title boundary.

11. All proprietary waterproofing systems to be installed in |
accordance with the manufacturers recommendations.

12. Plumbing to be carried out by a licensed plumber and in
accordance with the requirement of local authorities.

the contractor shall be responsible for all permits and
approvals. all hot water lines shall be fully insulated.
Sanitary plumbing shall be connected to existing system
with materials approved by the local authority.

13. Termite protection to be carried out in accordance with
AS3660.1Termite Management- New Building

STORMWATER DRAINAGE

1. All stormwater runoff is to be directed to 100mm dia
PVC downpipes to connect to an approved outlet in

accordance with AS3500.3 or to water tanks as per

Council Guidelines

 

2. The control of stormwater pollution from the building
site shall be carried out in accordance with the
"Best Practice Guidelines".

 

 

 

Site Plan
- } 1: 1200 7

EXACT POSITION OF BUILDING ON THE SITE

 

 

REFERENCE DOCUMENT
EXE25/0009
NOOSA COUNCIL
28 MARCH 2025

TO BE CONFIRMED BY BUILDER IN
ACCORDANCE WITH SURVEY PLAN

 

PROPERTY DESCRIPTION
Lot 31 on SP149578

 

 

Area 6.1949 Ha

 

 

 

NORTH

 

Engineering & Building Investigation Services

 

Proposed Alterations / Raising of
Existing Residence
Client - Robert Killeen

 

SITE PLAN

 

 

 

 

 

 

‘ 3 7 Sheet No. ig
Unit 2/4 Textile Ave. Warana_ PO Box 973 Buddina 4575 at Lot 31 (No. 81) Lake Flat Road — 2 ane A3-220221- 1
Boreen Point Drawn by —
Phone 07 54369199 Fax 07 54369198 fawn by HS | a
Checked by “re A st | Scale 1: 1200

 

 
Log in to download the original file

Reference Document_Plan - EXE25_0009.pdf · 487 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.