STORMWATER DRAINAGE NOTES
4.ANY CHANGES SHALL BE APPROVED BY THE ENGINEER IN WRITING PRIOR TO CARRYING OUT
OF THE WORKS
2.ALL LEVELS TO AHD.
3.ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.
4.ALL DIMENSIONS AND LEVELS ARE TO BE CHECKED ON-SITE BEFORE WORK COMMENCES.
5. DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE DRAWING.
6. FOR BUILDING SET-OUT REFER ARCHITECTURAL DRAWINGS
7. THE LOCATION AND DEPTH OF ALL SERVICES SHALL BE VERIFIED ON SITE WITH THE
REVLEVANT AUTHORITY PRIOR TO THE COMMENCEMENT OF WORKS
8. DURING CONSTRUCTION BARRIERS, LIGHTS & SIGNS SHALL BE MAINTAINED TO ENSURE SAFE
PASSAGE OF TRAFFIC AND PEDESTRIANS IN ACCORDANCE WITH THE REQUIREMENTS OF THE
LOCAL AUTHORITY.
9.ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT LOCAL AUTHORITIES
SPECIFICATIONS AND STANDARDS.
10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL RELEVANT AUTHORITIES
AND PAYING ALL FEES NECESSARY BEFORE COMMENCING WORK, FOR LOCATING ALL EXISTING
SERVICES AND FOR REPAIR OF ANY SERVICES DAMAGED AS A RESULT OF THE FOOTPATHS
AND PRIVATE PROPERTY SHALL BE REINSTATED TO THEIR ORIGINAL CONDITION.
11.ANY OBSOLETE/REDUNANT DRIVEWAY CROSSINGS AND DRAINAGE OUTLETS FROM THE
KERB AND CHANNEL INCLUDING ASSOCIATED PIPES ACROSS THE FOOTPATH SHALL BE
REMOVED AND THE KERB AND CHANNEL AND FOOTPATH REINSTATED TO THE LOCAL
AUTHORITIES CURRENT SPECIFICATIONS AND OR STANDARDS
12. THE CONTRACTOR'S ATTENTION IS DRAWN TO THE REQUIREMENTS OF THE WORKPLACE
HEALTH AND SAFETY ACT 1995. ALL WORK IS TO BE CARRIED OUT IN ACCORDANCE WITH THIS
ACT AND IN PARTICULAR THE CONTRACTOR TO ENSURE THE REQUIREMENTS OF THIS
SPECIFICATION WITH REGARD TO ‘NOTIFICATION IN RELATION TO A NOTIFIABLE PROJECT ARE
FULFILLED.
13.BENCHING OF PIT STRUCTURES SHALL HAVE A SMOOTH FINISHED SURFACE, AND PIPES
SHALL NOT PROJECT INSIDE THE SHAFT OF THE PIT.
14.STORMWATER DRAINAGE PIPES SHALL BE UPVC PIPE (MINIMUM SEWER CLASS SN8) TO AS
14. 1260 OR APPROVED EQUIVALENT. MINIMUM COVER TO ROOFWATER PIPES SHALL BE 50mm
EXCEPT WHERE REDUCED COVER IS REQUIRED TO DISCHARGE TO THE KERB AND CHANNEL.
15.MINIMUM PIPE GRADES FOR STORMWATER AS 3500 PART 3: PIPES SHALL COMPLY WITH
- 1.0% (MIN) GRADE FOR PIPES < 150 DIA.
- 0.5% (MIN) GRADE FOR PIPES > 150 BUT < 375 DIA.
16.CONCRETE DRIVEWAY AND PARKING AREAS SHALL BE CONSTRUCTED WITH 32 MPa
17.REFER HYDRAULIC DRAWINGS FOR SANITARY DRAINAGE LAYOUTS.
18.COMPACTION OF MATERIAL UNDER CONCRETE DRIVEWWAYS AND PARKING AREAS SHALL BE
(i) 75% MINIMUM DENSITY FOR COHESIONLESS MATERIAL (AS 1289 E5.1) AND
(ii) 90% RELATIVE DRY DENSITY (STD COMP.) FOR MATERIAL OTHER THAN (i)
GENERAL NOTES (SOME MAY NOT APPLY)
1. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL OTHER CONSULTANTS
DRAWINGS AND SPECIFICATIONS. 2. BEFORE PROCEEDING WITH THE WORK ANY DISCREPANCIES
IN THE CONTRACT DOCUMENTS SHALL BE REFERRED FOR DECISION TO THE ENGINEER.
3. DO NOT SCALE FROM DRAWINGS IF IN DOUBT, ASK!!
4. CONTRACTOR SHALL VERIFY ALL LOCATIONS OF SERVICES, ALL DIMENSIONS AND LEVELS
5. ALL MATERIALS & WORKMANSHIP SHALL BE IN ACCORDANCE WITH AS2890, THE (INCLUDING
THE QUEENSLAND SUPPLEMENT), THE QUEENSLAND BUILDING ACT AMENDMENT ACT 1991 AND
6. THE CONTRACTOR IS RESPONSIBLE TO OBTAIN RELEVANT APPROVALS PRIOR TO
7, ALL STORMWATER CULVERTS TO BE RCP CLASS 2. ALL ROOFWATER PIPES TO BE uPVC
8, SILT MANAGEMENT PLAN TO REMAIN IN PLACE UNTIL COMPLETION OF WORKS AND
9. ALL PROPOSED OPERATIONAL WORKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH
COUNCIL'S OPERATIONAL WORKS APPROVAL LETTER AND COUNCIL'S DECISION
10.CONCRETE KERB RAMPS SHALL BE ALIGNED TO COMPLY WITH COUNCIL'S STANDARD
DRAWING AND SHALL BE CONSTRUCTED STRICTLY IN ACCORDANCE WITH COUNCIL STANDARD
11. ALL TEMPORARY AND PERMANENT ROAD SIGNS AND LINEMARKING SHALL COMPLY WITH
THE CURRENT MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES(M.U.T.C.D.). EXISTING LINE
MARKING SHALL BE REMOVED BY GRINDING NOT"BLACKING OUT". COUNCIL DOES NOT
APPROVE OF BLACKING OUT OF EXISTING LINE MARKING. KERB MARKERS SHALL BE PROVIDED
FOR ALL WATER, TELSTRA AND ANY OTHER SERVICE CONDUIT ROAD CROSSINGS AS
APPLICABLE.
VEGETATION PROTECTION NOTES
1. TREES LOCATED ALONG THE FOOTPATH SHALL BE, TRANSPLANTED PRIORTO
CONSTRUCTION, OR REPLACED IF DESTROYED.
2. WHEN WORKING WITHIN 4m OF TREES, RUBBER OR HARDWOOD GIRDLES SHALL BE
CONSTRUCTED WITH 1.8m BATTENS CLOSELY SPACED AND ARRANGED VERTICALLY FROM
GROUND LEVEL. GIRDLES SHALL BE STRAPPED TO TREES PRIOR TO CONSTRUCTION AND
REMAIN UNTIL COMPLETION.
>
oS
DRIVEWAY TO BE CONSTRUCTED PER ~
RS-049, LEVELS SHOWN IN LONGSECTION
*
S
ss &
Ss
VERGE SWALE
DANLEY KEY JOINT WITH 20 X 40 JOINT SEALANT
R12 DOWELS AT 300CRS
VERGE TO BE SHAPED TO
DIRECT GROUND WATER THROUGH
J A LOW POINT IN DRIVEWAY (SEE DETAIL)
R JOINT AND DEPRESS FABRIC LOCALLY
SAW CUT - (SC
et to Seok
SKW CUTS (USING A SOFT CUT SAW)
SHALL BE INSTALLED WITHING 8HRS
OF CONCRETE PLACEMENT. WHERE AMBIENT
IS GREATER THAN 32 DEGREES
THIS\TIME SHALL BE REDUCED TO 4 HOURS
SL72 FABRIC (CENTRAL)
PAVEMENT DESIGN
Wot Scale
125
LINDSAY CONSULTING (i),
Giructurel & Gif Engineers)
7 LA
OFF. 2782 PARKER ATREET, MAROOAYDORE
PH 56 792 118
THIS DRAWING REMAINSAHE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
CLIENT AND PROJECT DESCRIPTION
NOEL MCMENAMIN
DRIVEWAY DESIGN
14 GROSVENOR TCE
NOOSA HEADS
3. TREE ROOTS SHALL BE TUNNELLED UNDER, RATHER THAN SEVERED. IF ROOTS ARE
SEVERED THE DAMAGED AREA SHALL BE TREATED WITH A SUITABLE FUNGICIDE. CONTACT
RELEVANT COUNCIL ARBORIST FOR FURTHER ADVICE.
DRAWING TITLE
DRIVEWAY DESIGN
SCALES
0 5
bedded analy
Orig. 1:200
SURVEY DATUM
ASSOCIATED CONSULTANTS
REVISION LIST
>
ORIGINAL ISSUE [09709720 |)
[avi720_|)
REVISED.
REVISED [25701721
NGL — i
|_500, | FFL - 15.050
w Ls
3 Ss
Ss
VERGE SWALE SECTION
sTanpe2? 3 S
ARDS 20 < a
©) U_NZ) ® eo eS
B99
STANDARDS 2004 (AU_NZ)
| 2009 | 2000 | 2000 | 2000 [2000 | 2000 | 2000 |
' ‘ ' Ground Clearance (units: mm)
Part # Front Wheelbase Rear
n 120 120 120
CS
gx” PROPOSED PAVEMENT LEVEL
KEY JOINT DRIVEWAY DESIGN
— Rt a the pay of the
rou [teoeeemsr sore Flat eae ena NOOSA COUNCIL
WARNING oe —e eervicea prior to construction.
S| DIAL BEFORE | |Siwous eves cuss wo| [teres canst || se APPROVED PLAN
VOU DIG | \zereuiieens® | |REME es t| ben inuscbunnestah Goma Oseatoreltonssenos' || | OPW20/0247 25 FEB 2021
www.1 100. com.au aries 70 ce, Aner ORRENT uuat To pasro ‘SERVES: Sui. ae re letter and Council's Decision Notice - Development Permit.
fomputer File
2010000W.OWG
4. ANY TREE LOPPING REQUIRED SHOULD BE UNDERTAKEN BY AN APPROVED ARBORIST.
DRAWING NUMBER SHEET] REV.
20-1000-F1 1\C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
LINDSAY CONSULTING 77), 7 LA RPEQ 4928 OFF. 2782 PARKER ATREET, MAROOAYOORE PH 5é 792 118 THIS DRAWING REMAINSAHE PROPERTY OF LINDSAY CONSULTING PTY LTD AND IS FOR THE SOLE USE OF THE CLIENT. NO PART MAY BE USED IN PART OR WHOLE WITHOUT PRIOR EXPRESS WRITTEN CONSENT OF LINDSAY CONSULTING PTY LTD PROFILE REQUIRED FOR Q10 VOLUMES\(AREA - .125M2) \Z CLIENT AND PROJECT DESCRIPTION NOEL MCMENAMIN DRIVEWAY DESIGN 14 GROSVENOR TCE NOOSA HEADS PROFILE REQUIRED FOR 100 VOLUMES (AREA - .165M2] \e DESIGN PROFILE (.2007 M2) DRIVEWAY “SWALE" (NJT.S) DRAWING TITLE SWALE DETAIL SUBJECT SITE) SCALES 0 5 pe eed Orig. 1:200 | SURVEY DATUM \ \ \ \ \ \ \ \ \ \ \ ASSOCIATED CONSULTANTS NOOSA COUNCIL APPROVED PLAN OPW20/0247 25 FEB 2021 REVISION LIST ‘A [ORIGINAL ISSUE 09709720 B | REVISED 11711720 [ | | | | Kesoutr Fie * 1 2010000W.0WG DRAWNG NUMBER SET] REV. || 20-1000-F1 1|B
Used in these records
Appendix C - Neighbour upstream driveway plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.7 MB (small file)
- File type
No other editions are linked here.