Appendix C - Code Assessment
Attached to the e-mail MCU15/0083 Development Application - 22 Ann St Noosaville.
Landscaping Code
!
of
700mm from the road pavement (not top of
kerb).
Services and utilities S7.1 Plant species used in landscaping S7.1-7.6 Not Applicable
O7 All landscaping works maintain adequate adjacent to substations, or adjacent to or on
There are no electrical services and utilities that will
safe distance from services and utilities electricity transmission line easements, are less
be affected by landscaping.
including substations, overhead powerlines, than 4m high at maturity and do not encroach
power poles and transformers, street lamps, within 3m of a substation boundary;
stormwater catchment pits, and underground OR
services and utilities. S7.2 For trees higher than 4m, trees are
planted
at a distance from any part of an electricity
transmission line at least equal to the expected
height of the tree at maturity (see Figure 14-17);
AND
S7.3 For power lines that connect to a
premises,
the height of plant species at maturity provides
for
a 2m clearance below the power line; (see
Figure
14-18)
AND
S7.4 Trees and large scrubs are located a
minimum of—
a) 5m from electricity poles and pillars;
b) 4m from street lamps;
c) 2m from stormwater catchment pits; and
d) 2m from underground services and utilities;
AND
S7.5 Plants are located to enable
tradespersons
to access, view and inspect service meters,
such
!
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.