Original source · versioned page text
Appendix C - Code Assessment
Attached to the e-mail MCU15/0083 Development Application - 22 Ann St Noosaville.
Natural Hazards Overlay Code
!
Infrastructure S17.1 Components of the sewerage treatment S17.1 Not Applicable
O17 Sewerage treatment plants maintain their plants that are likely to fail or may result in
function during flood events up to a 1% AEP contamination are—
1:100 year ARI) flood event. a) located above the level of a 1% AEP (1:100
ARI) flood event; or
b) are designed and constructed to exclude
water inundation or infiltration and resist
hydrostatic and hydrodynamic forces as a result
of inundation.
O18 Community Uses and Infrastructure S18.1 Community Uses and Infrastructure S18.1 Not Applicable
Uses are able to function effectively during and Uses are sited and constructed to ensure that
immediately after flood events. floor levels are not less than the AEP (or ARI)
c) avoiding concealment spots; levels identified below—
and a) Emergency service facilities- 0.2% AEP
d) maintaining safe sight (1:500 ARI);
distances to and from road and building b) Emergency shelter- 0.5% AEP (1:200 ARI);
corners, carpark entrances and driveways c) Police station- 0.5% AEP (1:200 ARI);
(see Figure 14-16); d) Hospital- 0.2% AEP (1:500 ARI);
e) maintain safe sight distances e) Electricity substation- 0.2% AEP (1:500 ARI);
at planting bed ends within carparks; f) Water treatment plant- 0.2% AEP (1:500
f) protecting solid fences from ARI);
graffiti by incorporating elements such as g) Power station- 0.5% AEP (1:200 ARI);
landscaping, creepers, murals or vandal h) Major electrical switch yard- 0.5% AEP
resistant paint; and (1:200 ARI); and
g) separating and defining i) Store for valuable records or items of historic
pedestrian and vehicle circulation routes. or cultural significance- 0.5% AEP (1:200 ARI).
O19 All lots have sufficient area that is above S19.1 The minimum area above flood level for S19.1 Not Applicable
the 1% AEP (1:100 year ARI) flood level or each lot, is in accordance with Table 13.11;
The proposal does not incorporate any new lots.
where modelling is not available, the highest AND
recorded flood level, to safely and adequately S19.2!Where the existing roads servicing a
See the original
The page text is free to read. Viewing or downloading an original file needs an account.