Appendix E - Structural Engineering Drawings (Issue 1 - Dated 07-02-2023) · EXE23/0035
ANY EXTERNAL TIMBER TO BE ABOVE GROUND
CLASS 1 DURABILITY OR H3 TREATED.
ALL EXTERNAL TIMBER TO BE PAINTED.
ANY EXTERNAL ABOVE GROUND TIMBER MUST BE
SEALED IN ACCORDANCE WITH AS1684 BEFORE IT IS 3 2
INSTALLED I.E. ALL CUTS, NOTCHES & DRILL HOLES S2.02 S2.02
MUST BE SEALED BEFORE INSTALLATION TO
MINIMISE THE INGRESS OF MOISTURE.
CUTS TO BE TREATED WITH H3 ENSEAL OR SIMILAR.
IT IS FURTHER RECOMMENDED THAT ONCE SEALED,
EXISTING UPPER MASONRY WALL
MEMBERS SHOULD HAVE A 'MALTHOID' COVER STRIP
1700(L) TO BE CORE FILLED.
(OR SIMILAR) APPLIED TO ALL TOP EDGES OF DECK N12 - 400 VERTICAL BARS.
JOISTS & DECK BEARERS TO AGAIN MINIMISE THE
INGRESS OF MOISTURE.
C1
DJ
WHERE SMARTLVL 13 OR SMARTLAM GL17 ARE
USED IN AN LOSP H3 APPLICATION PLEASE REFER
TILLING DESIGN GUIDES FOR INSTALLATION
Min./Max.
CONSIDERATIONS & RECOMMENDATIONS.
1700
JT1
ALL TIMBER TO BE KNOCK OUT FRONT FACE OF EXISTING
TERMITE RESISTANCE J1 BLOCK WORK FOR 2/N 12 x 500(L)
FB1
STARTER BARS EPOXY GROUTED INTO Check all dimensions before commencement of work.
H3 TREATED A SLAB REFER DETAIL. Check Site boundary dimensions from the Title plans.
Check Building Boundary clearances by set out.
S2.02 Notwithstanding the information supplied on this drawing, the
location, depth and extent of underground or overhead services
are to be confirmed and protected on site by the contractor prior
EXISTING LOWER LEVEL MASONRY
to commencement of works.
WALL SHOWN HATCHED TO BE
WP
CORE FILLED AND REINFORCED.
N12 - 400 VERTICAL BARS
C1
2 08.02.2023 NOTATION ADDED MS
EXISTING FLOOR 1 07.02.2023 FOR CONSTRUCTION MS
xFB
FRAMING P1 22.12.2022 PRELIMINARY MS
Issue Date Description By
FB2
1 Drawing title -
S2.02 UPPER FLOOR FRAMING PLAN
ALL EXPOSED STRUCTURAL
C1
KNOCK OUT FRONT FACE OF EXISTING
TIMBER TO BE FULLY ENCASED BLOCK WORK FOR 2/N 12 x 500(L)
AND WEATHERED PROOFED, i.e DJ
STARTER BARS EPOXY GROUTED INTO
ALL SURFACES TO BE PAINTED SLAB REFER DETAIL. Project -
AND CLAD IN F.C SHEETING.
PROPOSED DECK
EXISTING UPPER MASONRY WALL TO
BE DEMO AND RE-BUILT AS PER PLAN. EXTENSION
N12 - 400 VERTICAL BARS
1700
Max.
N12 - 400 HORZ. BARS
Client -
MJ
Paul Cooper Homes
EXISTING 190sq MASONRY PIER TO Site -
BE CORE FILLED AND REINFORCED
WITH 1/N16 VERT BAR. 24 Attunga Heights,
Noosa Heads
UPPER FLOOR FRAMING PLAN
SCALE A1 - 1:50
SCALE A3 - 1:100
Consulting Civil &
FOR STEP SIZES, FALLS IN SLAB & DOOR THRESHOLD
DETAILS REFER TO ARCHITECT'S DRAWINGS Structural Engineers
Project Management
ASSOCIATES PTY LTD
NOTES AND LEGEND & Planning
FOR GENERAL NOTES REFER DWG S0.01 & S0.02
PRIOR TO COMMENCEMENT OF WORKS, ALL 124 DUPORTH AVENUE
STRUCTURAL MEMBERS TO BE FULLY PROPPED AND JOISTS:
PO BOX 16 MAROOCHYDORE QLD 4558
BRACED BEFORE REMOVAL OF SUPPORTING WALLS J1 - 150 x 45 (LVL)13 JOISTS @ 450ctrs
E-MAIL: [email protected]
AND COLUMNS. DJ - DOUBLE JOIST, NAIL LAMINATED or
150 x 63 (LVL)13 SINGLE END JOIST. Ph (07) 5443 7777 Fax (07) 5443 7577
JOIST TRIMMER: Approved:
JT1 - 150 x 45 (LVL)13 JOIST TRIMMER
WALL LEGEND BEARERS: KEVIN COVEY BEng, CPEng, MIEAust, MSPEPNG, RPEQ1823
EXISTING INTERNAL LOAD BEARING STUD FRAMING OVER FB1 - 200PFC STEEL BEARER (Galv.) CHRIS CAMP BEng(Hons), MIEAust, RPEQ4944
FB2 - 200 x 45 (LVL) 13
EXISTING REINFORCED MASONRY WALLS OVER. xFB - 200 x 75 HDWD EXISTING BEARER Checked : MC Design : SC Drawn : MS
EXISTING INTERNAL STUD FRAMING UNDER POSTS: Scales : AS SHOWN
C1 - 89 x 89 x 3.5 SHS COLUMN (Galv.)
EXISTING REINFORCED MASONRY WALLS UNDER. xC - EXISTING HDWD COLUMN
Document Stage : CONSTRUCTION
ARTICULATION JOINT: Project : 223315 Sheet No. S2.01
190 REINFORCED BLOCK WALL OVER
MJ - BLOCK WORK ARTICULATION JOINT,
EXISTING 190 LOWER LEVEL BLOCK WALL TO BE CORE
WALL PLATE:
REFER DETAIL Digital Ref : 223315 - STRUC Issue : 1
FILLED AND REINFORCED WITH N12 - 400 VERT.
WP - 200 x 75 HDWD This document is copyright and shall not be copied without written
approval, nor shall it be used except for the development and the
site specified.
c:\12dS\data\12DSERVER\223315_2620\DWG Covey\Struc\Uncontrolled\223315 - STRUC.dwg Plot 08 Feb, 2023 - 08:34
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Structural Engineering Drawings (Issue 1 - Dated 07-02-2023).pdfRelated documentApplication case desk ↗
About this file
- File size
- 360 KB (small file)
- File type
No other editions are linked here.