04-01 Elevations · MCU22/0172.02
07 06 05 04 03 02 01
1,200 3,778 1,367 1,367 3,778 1,200
1,570
SCREEN
HEK-02 HEK-02 HEK-01 HEK-01
PARAPET LEVEL PARAPET LEVEL
RL 31.420 RL 31.420
BLK-01 BLK-01
SCR04 SCR04
700
700
P2 P2
UPPER LEVEL CEILING UPPER LEVEL CEILING
RL 30.720 RL 30.720
HEK-01
BOUNDARY
BOUNDARY
SLIDING
SCREEN
BLK-01
P4 W22 W21
2,700
2,700
UPPER LEVEL UPPER LEVEL
RL 28.020 RL 28.020
TIMBER PERGOLA TIMBER PERGOLA
SP SP
TIMBER POST W03 FIRE-01 FIRE-01 W10 TIMBER POST
3,000
3,000
TOW 26.020
FC-01
BAL-02
P2
RL 25.020
MID LEVEL BLK-01 BLK-01 MID LEVEL
RL 25.020 P2 RL 25.020
CONC-02 P2
BLK-01 G08
G03
P2
SCR04 SCR04
BLK-01
P4
D01 D04
2,920
2,920
GARAGE GARAGE
DOOR DOOR BLK-01 BLK-01
BLK-01 BLK-01
FINISH FINISH P1 P1
P1 P1
LOWER LEVEL LOWER LEVEL
RL 22.100 RL 22.100
LB LB
1 WEST ELEVATION
- Scale 1:50 A B C D
5,940 8,950 1,900
SCR-04 SCR-06 HEK-02
RL 31.420
PARAPET LEVEL PARAPET LEVEL
RL 31.420 RL 31.420
BLK-01 BLK-01 BLK-01
700
700
UPPER LEVEL CEILING P2 P2 P4 UPPER LEVEL CEILING
RL 30.720 RL 30.720
BOUNDARY
BOUNDARY
W14
SCR-04 SCR-06 SCR-04
2,700
2,700
TOW 28.260
RL 28.020
UPPER LEVEL UPPER LEVEL
RL 28.020 TIMBER PERGOLA RL 28.020
BLK-01 BLK-01
TOW 27.460
P2 P4
TIMBER
1,800
BLK-01 SHS FIRE-01
POST
P2 W04 BLK-01
W05
BLK-01 BBQ - REFER JOINERY P4
FC-01
P2 PF-01 DRAWINGS
3,000
3,000
200
P2 BLK-01
P2 TOW 26.020
SP SP
1,000
POOL
BLK-01
1,000
BLK-01 TOW 25.195 CONC-02 P2
265
P2
MID LEVEL MID LEVEL
RL 25.020 RL 25.020
175
G03
CONC-02
2,920
2,920
LIFT TO RL 23.297
LOWER
LEVEL BLK-01
BEYOND P1
LOWER LEVEL LOWER LEVEL
RL 22.100 RL 22.100
2 NORTH ELEVATION
- Scale 1:50
notes : issue amendment log by date
project: north date: 14/03/24
05 LIFT ADDITION TO BOTH UNITS FOR APPROVAL MF 24-03-23
1 The designs, drawings and specification are copyright and always
remain the property of Archend.
06 VE FOR CHECKING HC 25-05-23 PROPOSED DUPLEX, drawn: JJ
2 Before commencing construction:
07
08
ISSUE FOR REVIEW
COORDINATION ISSUE
HC
HC
30-05-23
06-06-23
22 GRANT STREET, NOOSA HEADS, QLD 4567 checked: MS
-Verify all dimensions and levels.
09 CONTRACT ISSUE HC 09-06-23 client: scale @ A1 : 1:50
-Verify location and levels of all services on site.
-Verify that floor levels and finished levels will enable connection to
10 BUILDING APPROVAL PP 31-08-23 INTEGRA PARTNERSHIPS scale @ A3 : 1:100
11 ISSUE FOR BA RFI JJ 14/09/23 [email protected]
services.
12 ISSUE FOR BA RFI JJ 20/09/23 title: project/drawing no. sheet: A1
3 Do not scale this drawing. When in doubt refer to Designer. QLD. QBCC: 15226654
3 SCALE 1:50 1:50
ELEVATIONS
13 ISSUED FOR CONSTRUCTION JJ 22/02/24
14 ISSUED FOR CONSTRUCTION JJ 14/03/24 D22-056_A04-01_14
GSPublisherVersion 393.0.95.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
04-01 ELEVATIONS.pdfRelated documentApplication case desk ↗
About this file
- File size
- 373 KB (small file)
- File type
No other editions are linked here.