Plans and drawings: the text below has words only, no drawings.
DRAWING SIZE — A2
KE
K. &
mh
LOT 108 ON SP 184118
Level Datum AHD
Level Origin PSM101160, RL 5.641m
co EXISTING K. & C. @
PARK ROAD
2/1009 uPVC PIPES LAID
AT 1 in 100 MIN. INSTALL
TO NEW KERB ADAPTORS &
MAKE KERB GOOD. TYPICAL.
MATCH KERB ADAPTORS
TO IL OF EXISTING KERB. 2
/y
INSTALL 1508 TO 1009
EX. SMI EXISTING SEWER MANHOLE
N EX. SWPT EXISTING STORMWATER PIT
C. EXISTING KERB & CHANNEL
LEGEND.
_--777 INDICATES PROPOSED SURFACE
SPLITTER. REFER TO ——?
MANUFACTURES. SPEC. a
J vs '
www.dialbeforeyoudig.com.au ms
DIAL1100 Kis
BEFORE YOU DIG GD-xxx
oo
CONTOURS AND LEVELS TO AHD.
INDICATES FINISHED SURFACE GRADE
EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
450Sq STORMWATER JUNCTION BOX,
PRE-CAST CONCRETE AND SEALED LID
GRATED DRAIN WITH HEAVY DUTY
GRATE. WIDTH AS NOTED.
1509 S/W PIPE INTO EXISTING
SIDE ENTRY PIT ON MITTI ST TO
COUNCIL STANDARDS AND GOOD
PRACTICE. MAINTAIN INVERT
LEVELS AS NOTED.
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
Sw/Ex
NL EXISTING SW DRAIN FROM
NEIGHBOURING ALOTMENT.
CONNECT TO NEW SP.
SITE PLAN — STORMWATER MANAGEMENT
Scale 1: 200
FOR THE SERVICE
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY RESPONSIBLE
XXX uPVC
—— SW/EX
INDICATES EXISTING SEWER LINE
INDICATES STORMWATER DRAIN PROPOSED
AS NOTED MIN 1 IN 100 FALL UNLESS
NOTED OTHERWISE. SIZE NOTED ON PLAN.
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
EXISTING SEWER LINE TO BE
REMOVED. REFER Drg. OW2.1 FOR
GALVANISED KERB ADAPTOR TO
LOCAL AUTHORITY STANDARDS.
CUT OUT LAYBACK KERB AS
NECESSARY TO INSTALL
GALVANISED KERB ADAPTOR
WITH NEAT, TIGHT FIT.
LAY BACK KERB ADAPTOR TO
EXISTING KERB DETAIL.
DN100 PC CLASS SNI0.
CONNECT NEW PIPE
TO KERB ADAPTOR.
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY.
REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF
FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION
WITHIN THE ALLOTMENT BOUNDARY TO BE IN ACCORDANCE
WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF
AUTHORITIES HAVING JURISDICTION, AFTER OBTAINING ALL
NECESSARY PERMITS AND APPROVALS.
4. THE CONTRACTOR IS TO CONFIRM THE POSITION OF ALL
EXISTING SERVICES AS INDICATED ON THESE AND ASSOCIATED
PLANS DO NOT CLASH WITH THE PROPOSED PIPE WORKS
PRIOR TO THE COMMENCING OF WORK.
5. ALL TRENCH EXCAVATIONS AND CONSTRUCTION TO BE IN
ACCORD WITH WORKPLACE HEALTH & SAFETY 1989 AND ANY
AMENDMENTS AND THE MINE REGULATION ACT.
6. STORMWATER DRAINAGE PIPES SHALL BE LAID AT A
MINIMUM GRADE OF 1 IN 100 U.N.O. JOINS ARE TO BE
CONSTRUCTED IN ACCORDANCE WITH THE MANUFACTURERS
REQUIREMENTS. (REFER NOTE 10.)
7. ALL PRECAST CONCRETE PIPES AND TO MANUFACTURED IN
ACCORD WITH AS. 4058.
8. STORMWATER PIPES SHALL BE THE FOLLOWING CLASSES:
8.1. REINFORCED CONCRETE PIPES (RCP) = CLASS 2.
8.2. uPVC 1008 OR GREATER = CLASS SN8’.
8.3. "STORMPRO' PIPES = CLASS ’SN8’.
9. ALL RCP PIPES TO HAVE THE FOLLOWING JOINTS U.N.O:
9.1. RCP 6009 OR LESS = RUBBER RING JOINT.
9.2. RCP 6009 OR GREATER = FLUSH JOINT.
10. ROOF STORMWATER TO DESIGN BY HYDRAULIC
CONSULTANTS TO CLASS ’SH’ U.N.O.
11, INSTALL SW MANHOLE AND FILED GULLY/INLETS IN
ACCORDANCE WITH AS1657 AND AS DESCRIBED BELOW:
111. MANHOLE/FIELD INLETS >1.35m DEEP = STEP IRONS.
11.2. MANHOLES 0.85m-3.0m DEEP = STEP IRONS.
11.3. MANHOLES >3.0m DEEP = FIXED ACCESS LADDER.
12. SEWERS 100mm DIAM. UPVC U.N.O. AND LAID AT A
MINIMUM GRADE OF 1 IN 60.
13. WATER SUPPLY PIPEWORK BELOW GROUND IS TO BE:
13.1. 63mm DIAM. OR LESS - HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
14. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY
PIPEWORK TO BE TYPE B COPPER.
15. WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS
AND ALL JOINS AND CONNECTIONS SHALL BE MADE ABOVE
THE SLAB.
16. FIRE HYDRANTS ARE 10 BE INSTALLED ARE TO BE
INSTALLED IN ACCORDANCE WITH AS2419.1, HOSE REELS ARE
TO BE INSTALLED IN ACCORDANCE WITH AS2441.
CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS
SITUATED IN VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO
BE FITTED WITH EITHER BRASS OR CAST-IRON COVERS.
17. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN
APPROVED CONCRETE PATH BOXES.
18. ALL WASTE PIPES AND WATER SERVICES PENETRATING
SLABS TO BE WRAPPED IN AN APPROVED FLEXIBLE JOINT
JOINT WRAPPING.
19. THE TERM 'SERVICE’ REFERS TO THE MINIMUM INTERNAL
PIPE DIAMETER UNLESS NOTED OTHERWISE.
Rev. | Description Date
Issue: FOR APPROVAL
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
‘[email protected]
ENGINEERS ‘awaua on™
DEBULD TA
Title: OPERATIONAL WORKS:
SURVEY & EXISTING SERVICES
Project 62 Park Road
Noosa Heads
Date: April 2018 | Drawn: CK | Design: TH
/ Drg No. te
25239-SW1.1) .
Checked: I
RPEQ 5835 N,
S Richardson |
he 1906.16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
OPW20-0033 Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.