NOOSA COUNCIL IDAS Development Application Decision Notice 7 of 12

Approval of works shall not be granted until all As Constructed information has been supplied and
accepted by Council.

Environmental Health

41.

42,

43.

44,

45.

46.

The developer must provide waste storage and disposal facilities in accordance with Planning Scheme
Policy No. 9 “Waste Management Multi-Dwellings and Commercial and Industrial Premises”, including an
external imperviously paved area correctly sized for all refuse and recycling containers and suitably
screened from public places and neighbouring properties. A bin wash down area is required with a cold-
water tap, hose and drain outlet connected to sewer. The drain outlet is to be designed to prevent storm
water entry to the sewerage system and this can be achieved with a nib wall 50mm high and 700mm x
700mm wide, or alternatively the waste area can be roofed.

Refuse containers must be provided in accordance with the requirements of the Environmental Protection
(Interim Waste) Regulation 1996 and (Waste Management) Regulation 2000, for the storage and
collection of refuse.

A clinical waste service provided by a licensed clinical waste contractor must be provided for the activities.

The development must allow refuse-loading areas to be located off street. All vehicles associated with the
collection of waste/recyclables, shall enter and leave the site in a forward direction.

A Waste Management Plan (Operational) in accordance with Planning Scheme Policy No. 9 “Waste
Management Multi-Dwellings and Commercial and Industrial Premises”, must be submitted for the day-to-
day operation of the development and approved by Council's Health Section prior to issue of development
permit for operational works.

It is critical that waste areas are properly planned. A copy of Planning Scheme Policy No. 9 explaining
exactly how to predict waste quantities and design waste areas is available from Council and the web.
The Plan shall include the following information: -

° The types of waste that will be generated from the activities approved within the development.

° Estimated volumes or tonnage of both recyclables and waste generated.

° Methods to be used for dealing with garden waste.

° Initiatives to minimize waste either by waste prevention, reduction, re-use or recycling.

° Description of procedures for getting all waste to the bins; the storage of bins and the collection of

bins by the contractor.

° A description of the design details of waste storage and recycling areas including size, location,
elevation and floor plan, methods of bin washing and system to prevent storm water getting into
sewer via the bin wash.

° A description of types and volume of waste storage containers to be used.

° The waste and recycling storage area shall include the provision of containers for all waste and
recycling materials including putresable matter, non-recycling waste, Paper/ cardboard, glass,
aluminium/steel cans, waste oil, styrofoam boxes, etc, and bin washing facilities connected to
sewer.

° A detailed description of vehicular access to collect waste. Where collection is off street, access
must allow vehicles to enter and leave the site in a forward direction.

Noise emission from mechanical equipment (air conditioners, refrigeration equipment or pool pumps etc)
shall comply with the following requirements:

46.1. The equipment shall be installed and located in a manner that prevents excessive noise in
accordance with Council’s Local Law No. 12 - Control of Nuisances. Infringement Notices (on-the-
spot fines) may apply for offences.

46.2. Aperson must not use equipment on any day if it makes or causes noise to be made —

46.3. From 10pm to 7am: More than the lower of either —

° 40 dB(A)
° 3 dB(A) above the background noise level

46.4. From 7am to 7pm: More than the lower of either —
° 50 dB(A)

SEP c:\datawrks\temp\1612970\04 05763.doc
Log in to download the original file

Appendix A.pdf · 6.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.