OPEN UNDERCROFT
SITE COVER OPEN UNENCLOSED
6.29 m2 (1%) GARAGE & LOWER LEVEL OPEN UNDERCROFT 14.16 m2
SITE COVER SITE COVER (roof - 600mm (3%)
182.99 m2 (34%) 16.70 m2 (3%) MAIN LEVEL
SITE COVER UPPER LEVEL
148.43 m2 (28%) SITE COVER
136.60 m2 (26%)
OPEN UNENCLOSED
27.43 m2 OPEN UNENCLOSED
(roof - 600mm) (6%) (roof - 600mm)
10.63 m2 (2%)
GARAGE & LOWER SITE COVER MAIN LEVEL SITE COVER UPPER LEVEL SITE COVER
SCALE 1:200 @ A3 SCALE 1:200 @ A3 SCALE 1:200 @ A3
SITE COVER
SITE COVER CALCULATIONS
SITE AREA 530.55
KEY
SU N P
SU
Setting 5 pm
MM AT
Se
LEVEL Area
ER H
tt i ng
SITE COVER LOWER 205.98 m2 38.8% 5 .3
SUN
WIN ATH
0p
SITE COVER MAIN 190.02 m2 35.8% GARAGE m
TER
P
SITE COVER UPPER 147.23 m2 27.7%
N
SITE COVER LOWER 182.99
OPEN Ris
SITE COVER in
UNENCLOSED g(
7a
SITE COVER LOWER 6.29
Rising (6.3
m)
0 am)
SITE COVER LOWER 16.70
REFER WD.107 FOR SITE SETBACKS/ LANSCAPING AND PLANNING
205.98 m²
REFER WD.207/ WD.208/ WD209 FOR FLOOR AREA MAIN LEVEL
setback means the minimum distance from
SITE COVER MAIN 148.43 any lot boundary to a building or structure,
excluding eaves, roof overhangs and
SITE COVER MAIN 14.16 awnings provided they encroach no more
than 600mm into the setback distance. DA2 Development Application
SITE COVER MAIN 27.43 issue issue / amendment
DA LF JH EN
190.02 m² site cover of the development, means the issue date drawn by
portion of the site, expressed as a client
UPPER LEVEL percentage, that will be covered by a building Kerry Bone
SITE COVER UPPER 136.60 or structure, measured to it's outermost project
projection, after the development is carried Bone Park Cr
location
SITE COVER UPPER 10.63 out. Refer local town plan for accurate 5 Park Crescent Sunshine beach
definition.
147.23 m² SITE COVER
ROOF Aboda Lee Foster • director
Design p - 0424 620 247
Scott Falconer • director
p - 0431 267 157
Group e - [email protected] e - [email protected]
SITE COVER ROOF 138.33 the aboda design group trust
ABN 56 266 884 746
Level 2, 1794 David Low Way Coolum Beach,
Q. 4573. PO box 2449 Noosa Heads Q 4567
t/a aboda design group • BSA License -15058097 • www.aboda.com.au
138.33 m² • This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
681.56 m² site prior to commencement of any works • These drawings are not to be used for scaling.
scale Scale as noted @ A3 issue
SITE COVER drawing no.
DA2
SCALE 1:200 @ A3 WD.105
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Proposal Plans (Rec 25.2.25) - MCU25-0021.pdfRelated documentApplication case desk ↗
About this file
- File size
- 19.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.