A6 - RESIDENTIAL USES CODE
                  SPECIFIC OUTCOMES                                PROBABLE SOLUTIONS                                         COMPLIANCE
 SPECIFIC OUTCOMES, PROBABLE SOLUTIONS AND ACCEPTABLE SOLUTIONS FOR RESIDENTIAL USES CODE
 FOR ALL RESIDENTIAL USES
 Effect of Use
 O1           The development does not adversely         S1.1   No solution provided.                           Complies
              impact on existing or future electricity                                                          The proposed development is adequately
              supply infrastructure;                                                                            serviced with all necessary infrastructure
              AND                                                                                               including electricity supply.
 O2           All uses and works maintain an             S2.1   Development for uses adjacent to or within      Not Applicable
              adequate safe distance from electrical            50m of an existing electricity substation
              infrastructure including substations,             incorporates noise attenuation measures to
              overhead powerlines, power poles and              mitigate noise impacts;
              transformers.                                     AND
                                                         S2.2   Development for uses adjacent to or within      Not Applicable
                                                                50m of an existing electricity substation
                                                                incorporates noise attenuation measures to
                                                                mitigate noise impacts;
                                                                AND
                                                         S2.3   A    minimum     separation    distance    is   Not Applicable
                                                                maintained from the electricity transmission
                                                                line to the closest boundary of habitable
                                                                buildings and child activity areas, as
                                                                follows—
                                                                a)       20m for transmission lines up to
                                                                         132kV;
                                                                b)       30m for transmission lines between
                                                                         133kV and 275kV; and
                                                                c)       40m for transmission lines greater
                                                                         than 275kV.
 Hot Water Systems
 O3           Hot water systems are installed and        S3.1   All hot water systems installed are—            Not Applicable
              operated to support the efficient use of          a)       solar systems; or                      The proposed development does not alter
              natural   resources    and     minimise           b)       electric heat pump systems; or         the existing arrangements for hot water
              consequent     pollution     such     as                                                          supply within the existing approved resort
              greenhouse gas emissions.                         c)       natural gas or LPG systems; or
                                                                                                                development
                                                                d)       any combination of a), b) or c).



HUMPHREYS REYNOLDS PERKINS PLANNING CONSULTANTS
20-Dec-10 - 10BR087.R01.010.docx

Used in these records

About this file

File size
41.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

05. Town Planning Report.pdf · 41.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.