Attachment 11- Code Compliance Report
Code MP4.1 Sustainable Buildings. Energy efficiency AO78.2 Complies with AO78.2
requirements are contained in the National Construction
Code. Where adjoining non residential uses, dwellings are The proposed development has been assessed against the
designed to incorporate suitable noise attenuation relevant noise provisions and an Environmental Noise
measures to reduce amenity impacts to occupants Assessment has been conducted to establish the necessary
of residential uses. management strategies for dealing with the anticipated
noise emissions.
Please refer to Attachment 8 – Environmental Noise
Assessment for further technical notes regarding the
proposed development and associated noise attenuation
measures.
AO78.3 Complies with AO78.3
Transparent doors and windows are designed and The proposed development does not locate transparent
located so they do not directly face transparent doors and windows, or private open spaces, within 10
doors or windows or the private open space areas metres of other dwellings.
of other dwellings or accommodation units within
10 metres;
AO78.4 Not Applicable
Where windows, balconies, terraces, verandas or The proposed development does not locate transparent
decks overlook or have the potential to overlook doors and windows, or private open spaces, within 10
the private open space of nearby properties or view metres of other dwellings.
into habitable room windows within 10 metres:
(a) windows have a sill height of not less than 1.7
metres above finished floor level;
(b) windows and other openings are permanently
NA
screened to a minimum height of 1.7 metres to
avoid overlooking;
(c) windows and doors use translucent glazing to
obscure views; or
(d) windows or balconies are offset by 45 degrees
or more.
Editor's note—refer to figure AP3-1C
AO78.5 Complies with AO78
Planter boxes, screens, pergolas, landscaping and The ground floor dwellings will be architecturally
architectural design of balconies are used to screen considered as to minimise overlooking from upper-level
dwellings to the ground floors private space areas.
Code Compliance Statements Page 43 of 136