N3 Wind Category Communications Pre-wired Steel Frame and Trusses 450mm Eave U.N.O.
19270 Note:
3710 4280 2650 6500 2130
Provide fly screens to all openable windows
& sliding glass doors
250 6000 250 2130
Date:
Garage Porch
2 Note:
3710 350 3930 250 470 90 2000 90 6000 250
1 3 Linen/ L'dry Garage Provide "crimsafe style' mesh security
4 250 3000 90 530 90 3520
Store
2400 7010 250 screens to front entry and laundry door
Bed 2 Robe Kitchen Bench Dining / Living
Provide full ht. Masonry articulation as per
Zero lot construction to 'NCC' 3.7.2.1 - 2019
with FRL 60/60/60 engineers report
450mm overhangs
DP
from brickwork Note:
590
DP
250
Provide 300mm deep Square Set openings
21-18 ASD
A
2690
2690
2690
350x350mm BRICK PIER
Beam & Bulkhead over - Exhaust fans ducted externally to soffit
ceiling to underside of trusses
Garage U.N.O. with a minimum flow rate of discharge
Conc. of 25 L/s (to comply with NCC - BCA
21 x 48 PANEL-LIFT
TAP
Garage Opening
DP 2130x890 {VOLUME 2}, PART 3.8.7.4). Refer to
Electrical plan for locations.
DOOR
4800
Garage
820
5540
Patio
LOADBEARING WALL
250
Tub
350
Tiled
Ducted A/C System Trusses designed to
VSD 18
LINEN
1760
L'dry
WM
8110
Client's Signature:
L'dry
2940
carry fan coil unit in ceiling with void to fit.
2590
90
820
ceiling to underside of trusses
Pass / Store
470x470mm BRICK PIER
Step Down
STORE
Beam & Bulkhead over -
1000
820
300mm eaves to Porch
75mm MH
820
21-36 ASD
LOADBEARING WALL
21-09 asw DP
Electric HWU 1000 Sq Set
250
250
250
90
90
90
1490
Ducted
13710
13710
2720
A/C HWU
Family
18-18AAW
1890
Motor
Living
2720
Tiled Provide water connection
Living
Living
2990
2990
point for D/W Tiled
Family
250
250
Dining
3400
Family
3860
Tiled DP
VSD 18
900
Robe
1910
ROBE
2610
90
12-18 asw
Provide mini cistern cock DW
Kitchen M/W
1430 470
Bed 2
Porch
3000
@1850mm from floor Porch
1900
90
1100
Tiled
1210 90
1480
720
1210 Sq Set
2130x990
Bed 2 Entry Conc.
Pass
1300
920
900 Upright Elec
Entry
90
DWR Cooker & Canopy R/H
1000
Carpet SA Tiled
SA Ref. Space
W.i.p
820
90
630
600
OHC OHC
590
110
6590
820
Pass
90
2090
90
90
90
250
1000 Sq Set
90
90
90
SA
Pass
1000
1000
Bed 3 SA
180 SA W.i.r
1620
W.i.r
820
820
SA
Carpet
720
18-18AAW
720 720
12-18 asw
90
90
90
Bed 1
3200
3200
Bed 3
Bed 4
Bed 4
3000
3000
3000
3110
900
90
Ens.
WC / Robe
VSD 18
VSD 18
ROBE
Bed 4 Bed 1
180
ROBE
Robe
1910
1910
1910
Bath
Bath
1700
Hardies Primeline
720
1490
Ens.
Carpet Carpet Newport Cladding
WC
1490
DP
09-06 asw 09-06 asw DP 12-18 asw 09-06 asw PCD MB DP
250
250
250
250
250
250
250
250
250
TAP
tiled reveals
to bathroom
Waterproofing & frog flap under bath window
GUTTERING TO COMPLY WITH NCC 2019
A
"OVERFLOW MEASURES" (REFER TO DETAILS)
90 90
250 3620 90 960 1000 4780 90 1360 90 1860 90 3920 250 730 Floor Areas
Bed 2 Pass Pass Kitchen W.i.p W.i.r Bed 1
250 3000 90 530 90 2720 90 960 90 530 90 3000 90 2750 90 3920 250
Living 146.1
Bed 3 Robe Bath WC Robe Bed 4 Ens. / W.i.r Bed 1 Garage 36.9
18540 730 Patio 16.2
Porch 4.0
19270 203.2 m2
All Content Copyrighted:-
C Client: Site Address:
Floor Plan
This design and/or print is the property of G Developments P/L
Address: P.O. BOX 600 and is protected by the Commonwealth Copyright Act 1968. It
must not be used or reproduced in whole or in part without Jason Philip Oakes and Lot 41
PARADISE POINT, 4216 written permission. Any attempt to copy, use or reproduce the
www.gdevelopments.com.au
same, in whole or in part, will result in legal proceedings. Janette Karen Oakes Number 4 Bruce Street Plot Date: Drawn: Rev:
GENERAL NOTES:
Product: 6/10/2021 M.F.
Drawings are to be read in conjunction with the relevant client-builder
The Outlook Estate
ACN: 116332220
B
contract. Contract is to take precedence over drawings including but
Anzio Mod Scale: Checked: Checked Date:
TS
not limited to: - finishes, inclusions, upgrades, exclusions, additional
ABN: 77116332220 costs and works by the owner/builder. Incorrect inclusions or omissions
GLENEAGLE QLD 4285
EN
QBSA: 1086689 or typographical errors are not to be used in the interpretation of any 1:100 M.F. 24.08.21
M
Coastal Facade
information in these drawings. Nor can they be used to claim any
P
SP: 298418 Sheet: Job No:
O
L
additional or alternate items or services as a result of such errors. The B 24.09.21 Client changes - electrical and kitchen ILO linen M.F.
/
P
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Cover letter - GIA application.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.7 MB (small file)
- File type
No other editions are linked here.