Re: Application for a Development Permit for 07/2291 Detached House situated
at 46 Elizabeth Street Noosaville described as Lot 2 RP 78252
I refer to the above application and wish to advise that following preliminary
examination of the plans, the following information is required to be submitted:-
1. As the proposed house does not comply with Probable Solution S1.1 in regards
to setbacks please provide amended plans or additional information
demonstrating that the proposed dwelling meets the Specific Outcome O1 of the
Detached House Code.
column 1 column 2
Specific Outcomes Acceptable solutions (if self-assessable)
Probable solutions (if code assessable)
Setbacks S1.1 The minimum setback of the Detached house
O1 Buildings and other structures are appropriately
or dwelling unit and associated buildings and
designed and sited to- structures from boundaries is not less than the
minimum specified in Schedule 1; or
a) provide amenity for users of the premises as well S1.2 Where there is a conflict between boundary
as preserve the visual and acoustic privacy of setbacks in Schedule 1, the greater of the setbacks
adjoining and nearby land uses; prevails;
b) preserve any existing vegetation that will buffer
the proposed building from adjoining uses; AND
c) allow for landscaping to be provided between
buildings; and S1.3 If there are no applicable setbacks shown in
d) maintain the visual continuity and pattern of Schedule 1, the siting provisions of Part 11 or 12 of
buildings and landscape elements within the street. the Queensland Development Code apply.
SBR alternative provision to QDC Parts 11 and SBR alternative provision to QDC Parts 11 and
12, P1, P2 and P7 12, A1, A2 and A7
2. Please provide a stormwater drainage plan and final surface levels for the site
and adjoining properties to the rear and sides of the site on. Plans of the
drainage design shall be prepared by a Registered Professional Civil Engineer.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
The site is subject to flooding from the Noosa River and any buildings
constructed on site will need to be built to Council’s Minimum Floor Height
requirements as defined in Council’s Planning Scheme and on Council’s Scheme
Maps. In this regard, the minimum floor height is RL 2.5 (AHD). Although areas
utilised for carparking purposes associated with the residential use may be
reduced by 0.3m.Filling of the site may be required to achieve these levels, or
alternatively buildings could be suspended.
As the site is proposed to be filled, appropriate stormwater drainage pipes shall
be installed within the site to collect and discharge stormwater runoff from all
adjoining properties to prevent additional ponding/flooding on these properties.
It should be further noted that as the property is affected by the Natural Hazards
Overlay with Acid Sulphate Soils, should filling of the site require 500m3 or more
of material with an average depth greater than 0.5m then the application will also
require:
a) a report on the Identification and Investigation of Acid Sulfate Soils prepared
in accordance with Part 6 of the State Planning Policy 2/02 Guideline:
Planning and Managing Development involving Acid Sulfate Soils; and
b) a report on the level and method of treatment of any identified affected areas
prepared in accordance with Part 9 of the State Planning Policy 2/02
Guideline: Planning and Managing Development involving Acid Sulfate Soils;
3. As the proposal does not comply with Acceptable Solution S6.1 with respect to
height please provide amended plans demonstrating that the proposed house
does not exceed 8m in height measured from natural ground surface to the top of
the roof or parapet at any point.
Please provide 4 copies of all information that you are providing. In addition, it would
assist Council if you could also provide an electronic copy of your response.
Please be aware that under Section 3.2.12 of the Integrated Planning Act, the applicant
is to respond to any information request within 12 months of the request or otherwise,
the application lapses.
Under the provisions of the Integrated Planning Act 1997, you as the applicant, have
three options available in response to this Information Request. You may give the
assessment manager (in this instance Council) and each referral agency (if any):-
1. all of the information requested; or
2. part of the information requested together with a letter asking the assessment
manager and each referral agency to proceed with the assessment of the
application; or
3. a letter:-
a) stating that you do not intend to supply any of the information requested; and
b) asking the assessment manager and each referral agency to proceed with the
assessment of the application.
The above information is required to be submitted, prior to assessment of the
application. If any further matters arise as part of assessment of this application, you
will be advised accordingly.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
Page 3
Should you have any further queries in relation to the above, please do not hesitate to
contact Duncan Thompson on the above number.
Yours faithfully,
Daniel Smith
ASSISTANT PLANNING OFFICER
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
Used in these records
Request for Further Information - 010.2007.00002291.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 15 KB (small file)
- File type
No other editions are linked here.