Original source · versioned page text
Attachment B - Code Compliance Assessment
Performance Outcomes Acceptable Outcomes Planning Comment
(a) biodiversity values, connectivity and Works application will not adversely impact
ecosystem functioning; and on ecologically important areas.
(b) the long term physical integrity of
waterways, wetland and areas of
native vegetation.
Water Supply for Fire Fighting Purposes
PO3 AO3.1 Complies
Development provides an adequate water Premises are connected to the reticulated The premises are connected to the
supply for fire fighting purpose which is water supply. reticulated water supply.
reliable, safely located and freely
accessible. Editor's note—For reconfiguring a lot, water
supply needs to provide for a minimum flow
and pressure of 10 litres a second at 200kPa
at all times for fire fighting purposes.
OR
AO3.2
Where there is no available reticulated
water supply, the premises has:
an accessible dam, swimming pool or
water tank available for fire fighting
purposes with an onsite water volume of
not less than 5,000 litres; and
a water supply outlet pipe 50 millimetres in
diameter fitted with a standard fire brigade
fitting connected to the water supply
jrey.au | (07) 3106 3221 | [email protected]