Attachment B - Code Compliance Assessment
Performance Outcomes Acceptable Outcomes Planning Comment
Attack Level 29 requirements as per
AS3959; and
(d) is designed so that buildings and
structures are sited in locations of
lowest hazard within the lot and
elements of the development least
susceptible to fire are closest to the
fire hazard.
Firebreaks and fire access tracks
PO8 AO8.1 N/A
Firebreaks and fire access tracks provide: Where development involves the creation No firebreaks or fire access tracks are
(a) adequate access for fire fighting of a new road and lots, a firebreak is provided as part of this development.
and other emergency vehicles; and provided by providing a cleared road
(b) adequate access for the evacuation reserve not less than 20 metres wide and
of residents and emergency maximum gradient of 12.5% around the
personnel in an emergency perimeter of the subdivision, between the
situation. created lots and surrounding vegetated
lands.
OR
AO8.2
Fire access tracks are provided between
the created lots and surrounding
vegetated land that:
(a) have a cleared minimum width of 6
metres;
(b) have a maximum gradient of 12.5%;