2016-02-02 P&O Committee - Item 3 - Attachment 4 - Mary River Environmental Values and Water Quality Objectives
Mary River environmental values and water quality objectives
Table 12 Drinking water EV: Priority water quality objectives for drinking water supply in the vicinity
of off-takes, including groundwater, before treatment
Indicator Hazard and critical control point (HACCP) rating
(refer notes 1, 2 for explanation of HACCP levels)
1
Suspended solids • Level 1: 25 mg/L
2
• Level 2: 100 mg/L
Blue-green algae • 2,000 cells/mL
(cyanobacteria)
1
Algal biomass • Level 1: > 30,000 cells/mL Cylindrospermopsin or Microcystin
2
• No Level 2
1
Algal toxin • Level 1: 0.1 µg/L Microcystin or 0.2 µg/L Cylindrospermopsin
2
• Level 2: 4 µg/L Microcystin or 1 µg/L Cylindrospermopsin
Taste and odour • Level 1: 5 µg/L Geosmin or 10 µg/L MIB or 10 µg/L combined Geosmin
1
& MIB
2
• Level 2: > 30 µg/L of both Geosmin & MIB combined
1
Cryptosporidium • Level 1: > 0 cyst
2
• Level 2: 10 cysts per 10 L
1
Giardia • Level 1: > 0 cyst
2
• Level 2: 10 cysts per 10 L
1
E coli • Level 1: > 60 cfu/100mL
2
• No Level 2
1
Total coliforms • Level 1: > 800 cfu/100mL
2
• No Level 2
1
Manganese (soluble) • Level 1: 50 µg/L
2
• Level 2: 200 µg/L
1
Iron (soluble) • Level 1: 50 µg/L
2
• Level 2: 200 µg/L
1
Turbidity • Level 1: 25 NTU
2
• Level 2: 100 NTU
1
Colour • Level 1: 50 Hazen Units
2
• No Level 2
1
Conductivity • Level 1: > 50% change from long term median
2
• Level 2 same as Level 1 (no treatment options to remove salt)
1
Dissolved oxygen • Level 1: < 4 mg/L at surface
2
• No Level 2
Pesticides • Level 1: Above detection limits specified by Qld Health Scientific
1
Services
2
• Level 2: Notification of spills or illegal dumping
1
Hydrocarbons • No Level 1
2
• Level 2: Notification of spills or illegal dumping
Source: Environmental Values and Water Quality Objectives for Wivenhoe, Somerset and North Pine Dam, SEQ Water,
2005.
Notes:
1. “Level 1” means Level 1 Hazard and Critical Control Point (HACCP) response rating, namely – Treatment plant
process change required to ensure water quality and quantity to customers is not compromised.
2. “Level 2” means Level 2 Hazard and Critical Control Point (HACCP) response rating, namely –Treatment plant
process change required but water quality and quantity to customers may still be compromised.
27
Document Set ID: 20002123
Version: 1, Version Date: 21/12/2015
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.