ITE Consulting
ABN: 45657586949
34 Flamingo Crescent, Thornlands
4164
Brisbane
Contact: 0424110122
Email: [email protected]
21 March 2025
Ref: ITE0248
Attention:
Patricia Peranchiguay
RE: Response to Information Request Letter – 51 Elanda Street
I refer to the proposed development on 51 Elanda Street and this letter forming a response to the Information
Request from council dated 10 January 2025. The following has been prepared to assist in responding to the
traffic engineering items raised and, for ease of review, the relevant items are reproduced and responded to
directly below. In preparing this advice, reference has been made to plans and swept paths, provided in
Attachment A to this advice.
Quality Information
Document 51 Elanda Street Traffic Response Letter
Ref MCU24/0153 OPW24/0202, PLM24/0024
Date 21/03/2025
Prepared by Herman Joubert MEng CEng CPEng RPEQ
Reviewer and Approver Herman Joubert MEng CEng CPEng RPEQ
51 Elanda Street Traffic Response Letter 21 March 2025 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 15 (of 17)
Page 2
1. Introduction
This response deals with the traffic engineering matters raised by council in the RFI letter dated 10 January 2025.
Traffic engineering design advice has been incorporated into preparing this response in order to ensure efficiency
and safety will be achieved, given the proposed development scale and intensity.
2. Response Assessment
2.1. Council Feedback
Driveway, Crossover and Ramp
Issue – Driveway Crossover and Internal Down Ramp SCCE’s Engineering Plans does not include sufficient detail
about the proposed driveway crossover and internal down ramp.
Any driveway crossover and internal down ramp must meet the recommendations contained in ITE Consulting’s
Traffic Impact Statement (Report No. 001, Rev. 01) dated 25 November 2024.
Information Required
11. Provide additional detail about the proposed driveway crossover and internal down ramp. The additional detail
must be prepared by a suitably qualified person, be suitable for construction, meet the recommendations
contained in ITE Consulting’s Traffic Impact Statement (Report No. 001, Rev. 01) dated 25 November 2024 and
include, but not limited to:
a) Dimensions, spot levels and grades of the driveway crossover and down ramp;
b) A longitudinal section extending from the centreline of Elanda Street to the bottom- most section of the
proposed basement demonstrating that the B85 vehicle will not scrap or bottom out while entering and
exiting the site.
Door Opening Clearance
Issue – Carparks 7 – 10
The B85 Vehicle Swept Paths provided by ITE Consulting do not adequately demonstrate that proposed carparks 7-
10 comply with Figure 5.2 of AS2890.01. Council is concerned that operators are unable to enter and exit their
vehicles without their doors colliding with columns, walls or other adjacent vehicles.
Information Required
12. Provide additional detail demonstrating that Carparks 7 – 10 comply with Figure 5.2 of AS2890.01. The
additional detail must be prepared by a suitably qualified person and be supported with amended Swept Paths
Car Stackers
Issue – Car Stacker (Carparks 1 – 6)
The proposed car stackers do not meet the manufacturer’s requirements. Unless the following is addressed,
Council considers proposed carparks 1 – 6 to be non-compliant and not functional.
1. The minimum aisle width available to the proposed car stackers (1&2, 3&4) is less than the minimum aisle
width required as per the manufacturer’s Product Data sheet provided on Page 39 of ITE Consulting’s
Traffic Impact Statement (Report No. 001, Rev. 01) dated 25 November 2024. The submitted Swept Paths
51 Elanda Street Traffic Response Letter 21 March 2025 2
Page 3
fails to justify the reduced aisle width as the B85 vehicle is required to manoeuvre within the car stacker.
Refer to the below extracts.
2. The proposed basement carpark does not include the necessary maintenance shafts required to service the
proposed car stackers as described in Page 37 of ITE Consulting’s Traffic Impact Statement (Report No.
001, Rev. 01) dated 25 November 2024.
3. No detail has been provided demonstrating the internal drainage ‘pit floor’ or external ‘pit edge’ (where
required) as described in Page 41 of ITE Consulting’s Traffic Impact Statement (Report No. 001, Rev. 01)
dated 25 November 2024.
Information Required
13. Provide amended plans that demonstrate proposed Carparks 1 – 6 (car stackers) are compliant with the
manufacturer's Product Sheet (contained in ITE Consulting’s Traffic Impact Statement (Report No. 001, Rev. 01)
dated 25 November 2024). The amended plans must be prepared by a suitably qualified person and include, but
not be limited to:
a) minimum 6.5 metre aisle width where the aisle services a car stacker, unless otherwise justified (i.e.,
demonstrate the B85 vehicle can enter the carpark square without manoeuvring with the carpark);
b) demonstrate that the location and linemarking of the proposed car stacker is suitable for the entire
system, including the necessary maintenance shafts and hydraulic mechanisms; and
c) demonstrate the recommended drainage features of the car stacker are provided.
2.1. ITE Consulting Response
Driveway Crossover and Ramp
A ramp clearance assessment has been carried out based on an AS2890.1:2004 B99 vehicle which shows that
sufficient ground and head clearances will be achieved. An RPEQ certified clearance assessment is provided in
Appendix B.
Door Opening Clearance
The plans in Appendix B illustrate that clearance envelopes as per Figure 5.2 of AS2890.1:2004 will be achieved.
This allows for standard user Class 1 A bays of 2.4m width plus 300mm manoeuvring clearances to accommodate
turn paths as well as door opening requirements measured 1500mm from the centre of each bay.
Car Stackers
The car stackers do not include dividing walls between the bays. As such standard entry clearances as per Figure
5.2 of AS2890.1:2004 can be achieved, including the use of the 1100mm clearance adjacent to car bay 1&2 for the
top vehicle. The pit access is also manufactured to allow vehicle payloads when traversing over it. For the entry
and exit movements of the bottom vehicle, the movement of a standard B85 vehicle can enter and exit Car Bay
1&2 within the maximum allowable 3-point turn movement, given that when the bottom stacker has risen, safety
nets / walls demarcate the bottom stacker. The proposed aisle width of 5.9m is thus considered sufficient to
accommodate the minimum turn movements required fronting car bays 1&2, as indicated in Appendix B. Details
51 Elanda Street Traffic Response Letter 21 March 2025 3
Page 4
provided by the manufacturer were overlaid on the plans which indicates the car stacker system envelope and
associated turn paths.
Relevant line marking will be done during Operational Works and detail design stages based on manufacturer
requirements as determined at that time. Details provided by the manufacturer outlining the external extents of
the car stackers were overlayed in Appendix B which indicates the likely external line marking outlines.
All drainage and stormwater features are referred to the civil engineering plans which will also be finalised during
Operational Works stages.
3. Summary
In summary it was found that the proposed layout would be safe and functional and compliant with relevant
AS2890.1:2004 standards. The proposed development is not expected to have a significant impact on safety of
motorists or pedestrians or queueing related matters. The parking layout would also be compliant with
AS2890.1:2004 clearance and minimum turn movement requirements when entering / exiting these parking bays.
I trust that the above and attached are clear and assist council with their review. Should you have any questions,
please feel free to call me to discuss.
21/03/2025
Approved by:
Signed Date
Herman Joubert
RPEQ No.: 25899
51 Elanda Street Traffic Response Letter 21 March 2025 4
Page 5
APPENDIX Layout Plans 51 Elanda Street Traffic Response Letter 21 March 2025
Page 6
B2
B7 31
B8
A B C D E F 14 G #LayID
H Ha
B
31
B6
14
BACK
1.5M SET A2
28
| 47.157m
ARY 48°24'00"
ROPERTY BOUND A7
P 29
CC3 CC3 CC3
CC2
WALL UNDER RAMP
SLAB ABOVE
STORAGE AREA UNDER RAMP
1:4
1 1
1,750
UNDER RAMP PARKING AREA
PROPERTY BOUNDARY
UNDER RAMP PARKING AREA
A13 A13 RL45.000
IN GROUND CAR IN GROUND IN GROUND CAR
2.233m
E D
LL DASH 29 29
RAMP WA
3,
STACKER CAR STACKER STACKER
94
0
5.5x2.85M 5.5x2.85M 5.5x2.85M
1:6
1:20
A2
5,400
1,900
2 2
'40" | 2
28
2,231
1:30
A7 BICYCLE
155°07
LIFT
29
2,450
STORAGE
750 1,000
SHAFT
RL44.342 OPEN
TBACK
RAMP COMMUNAL
DARY
1,100 POOL
1&2 3&4 5&6 7 8 9 10
3 3
325
6M SE
324°49 | 11.778m
300
BOUN
PIT
CARSTACKER SHAFT
ACCESS
BELOW LIFT ACCESS AREA
1:8
ERTY
6
19
4,
A A
PROP
RL43.350
27 A12 27
#LayID
BIN 1:30
BASEMENT DOOR
STORE
RL43.350 RL43.700
5 BASEMENT 1:8
OVERHEAD PLANTER CC1
GF VISITORS CAR PARKING AB
LANDING
RL43.849 HANDRAIL
OVERHEAD
STORAGE
AREA 1.5M SETB
ACK
RL45.758
UP
PROPERT GATE
Y BOUND
ARY
241°14'00
1
2
3
" | 43.15m
4
5
6
7
8
10
9
11
12
GATE 5
BASEMENT
ACCESS FROM
6
5
E F PEDESTRIAN
4
G H
3
SCALE
2
1:14 RAMP
C D
1
A B FOOTPATH
6
5
4
3
2
1 0 1 2 3 4 5m LANDING
1
B RL45.758 Ha
31 B2
B9 31
LANDING
LANDING
14
N
scale 1:75
1 0 1 2 3 4 5m
FLOOR PLAN - BASEMENT PROPOSED MULTIPLE RESIDENCE Development Approval Issue rev. A
51 ELANDA STREET, SUNSHINE BEACH 20-11-24 pag. 16
The designs, drawings and specifications within these drawings are copyright and remain the property of ARCHEND. Do not scale this drawing. Any discrepencies to be confirmed with the Designer.
GSPublisherVersion 759.0.71.0
Page 7
COMPLEX
MULTI LE
VEL UNIT B2
B7 31
B8
A B C D E F 14 G #LayID
H Ha
B
31
B6 SOFT
14
LANDSCAPING
UILDING N
OT A2
END OF B m 28
SURVEYE
D
48°24'0 0" | 47.157
Y NW
OPERTY BOUNDAR 24
BBQ COMMUNAL
PR EAVE OVER DRIVEWAY GARDENS
BACK KITCHEN
1.5M SET
BALCONY
SOFT LIVING 25.18 m2
1 LANDSCAPING 1:4
COURTYARD
1 CP
BUP106270
HOLD POINT
1:8
DINING
2,000
UNIT 1
2.233m
PROPERTY BOUNDARY
1:20
89.26 m2
WIR
6,000
A2 UNIT 1
2 2
10M SETBACK
28 ABL E
PERME
6M SETBACK
2 ACCESS
48
'40" | 2
DRIVEWAY 4, A P E D
1:20
RL49.857
1:
5 LANDS
C
PAVEM
ENT
b.
L'DRY K 80
1:40 Low Vegetation BED 2 MASTER 6,000
155°07
1:8 LIFT SHAFT
BATH ENS
20.71 m2
4
2
3
5
6
8
9
7
1
D
COMMUNAL
w.c.
w.c.
UP
Custom Text
COURTYARD BIR b. b.
UNIT 1
FIRE RATED POOL
3 GATE STAIRCASE 3
ACCESS
DARY
BBQ
SW RL49.315
324°49 | 11.778m
26 SOFT
14
10
12
13
15
16
18
17
11
KITCHEN LANDSCAPING
BOUN
b.
BIR NE
TBACK
LANDSCAPED FIRE STAIR w.c.
26
EXIT LIVING
Low Vegetation
1:16 PERMEABLE
A BATH A
ERTY
PAVEMENT
27 A12 27
1:20
6M SE
#LayID VISITOR PARKING VISITOR PARKING
PROP
COURTYARD UNIT 2
D DINING
13.83 m2 88.68 m2 CP
SOFT LANDSCAPING BED 2
1:20
WALKWAY 5
AREA
BALCONY GTP689
1:20 RAMP
25.52 m2
WIR
1:20 RAMP
1 2
PEDESTR UNIT 2 L'DRY MASTER
TBACK
IAN ACCE STEP
SS FROM GATE ACCESS UNIT 2
1:20 RAMP STREET LETTERB ACCESS
OX
LANDING w.c. K
ENS
8M S E
Strip vege 1.5M SET
tation with BACK
FOOTPATH
Trees
1,800
EXISTING
STRIP VE
b. b. POOL
GETATION
TO BE RE
-DESIGNE ACCESS
D PROPERT
Y BOUND
LANDING ARY 241°14'00 EAVE OVE
R FOOTPA
PLUNGE
" | 43.15m TH POOL
1:20 WALK EXISTING
WAY STRIP VE
RL49.246 GETATION
TO BE RE
-DESIGNE
D
14,097 EXISTING
PEDESTR
IAN FOOT
GATE 5
PATH & ST
LANDING AIRS TO B
E RE-DES
1:14 RAM IGNED
P SOFT
RL48.013 BASEMENT LANDSCAPING
9,000 LANDING ACCESS FROM
A B C D E 1:14 RAMP
F PEDESTRIAN G H
RL46.886 FOOTPATH
EXISTING PUBLIC PATHWAY REDESIGNED 1 LANDING
AS DDA COMPLIANT ACCESSIBLE PATHWAY SE
2B
3 Ha
25 31 4 5RL45.758 B2
B9
LANDING
6 31 LANDING
14 7
8 9 RL44.697
HANDRAIL BOTH SIDES 10 11
AS PER AS1428.1 RL43.637
B U CP
P3 N
58
5
scale 1:75
1 0 1 2 3 4 5m
GENERAL ARRANGEMENT- GROUND FLOOR PROPOSED MULTIPLE RESIDENCE Development Approval Issue rev. A
51 ELANDA STREET, SUNSHINE BEACH 20-11-24 pag. 17
The designs, drawings and specifications within these drawings are copyright and remain the property of ARCHEND. Do not scale this drawing. Any discrepencies to be confirmed with the Designer.
GSPublisherVersion 759.0.71.0
Page 8
Private Swimming Pool
UNIT 6 ROOF TERRACE
59.400 Balustrades to Building Code
BOUNDARY
BOUNDARY
Requirements
58.900
Garden beds for ground Handrails to Building Code
covers and planting Requirements
57.900 57.900
ROOF ROOF
57.900 57.900
200
12M
HEIG
HT LI
MIT
Fire Stair
Entrance UNIT 6 UNIT 6
2,900
Lift Access
BALCONY Garden beds for ground
covers and low planting
55.300
54.800 54.800
LEVEL 2 LEVEL 2
54.800 54.800
200
Fire Stair UNIT 4
Entrance
UNIT 4
2,900
BALCONY Garden beds for ground
covers and low planting
52.200
51.700 51.700
LEVEL 1 LEVEL 1
51.700 51.700
200
14,550
14,550
Visitors Carparking UNIT 2
FFL EXISTING
(2 spaces) to Traffic Eng report Fire Stair BALCONY FFL EXISTING
UNIT 2
2,900
Entrance Lift Access
RL 49.940 RL 49.940
49.304
1,340
48.600 48.600
GROUND GROUND
48.600 48.600
500
CC3 Retained Planter beyond CC2
1m ABO
VE NG Garden in Natural Ground
for ground covers and low planting
IN GROUND CAR
RT IN GROUND IN GROUND CAR RT
RL 46.710
STACKER CAR STACKER STACKER Retained Planter beyond RL 46.710
NATUR
5.5x2.85M 5.5x2.85M 5.5x2.85M AL GRO
7 8 9 10 UND
SWIMMING 45.408
4,500
4,750
Ramp to Traffic Eng report POOL
BASEMENT Lift Access BASEMENT DOOR
43.849
43.700
43.350
BASEMENT BASEMENT
43.350 43.350
2,850 2,850 2,850 300 2,400 2,400 2,400 2,400 325
A SECTION
#LayID Scale 1:75
SECTION A PROPOSED MULTIPLE RESIDENCE Development Approval Issue rev. A
51 ELANDA STREET, SUNSHINE BEACH 20-11-24 pag. 27
The designs, drawings and specifications within these drawings are copyright and remain the property of ARCHEND. Do not scale this drawing. Any discrepencies to be confirmed with the Designer.
GSPublisherVersion 759.0.71.0
Page 9
UNIT 5 Unit 5 Private Pool
HT LIM IT
ROOF TERRACE 12M HEIG
59.300
Garden beds for ground
covers and low planting
58.300
ROOF ROOF
57.900 57.900
UNIT 5
BALCONY
3,100
Garden beds for ground Garden beds for ground
Garden beds for ground
covers and low planting covers and low planting
55.322 covers and low planting
LEVEL 2 LEVEL 2
54.800 54.800
Garden beds for ground UNIT 3
3,100
covers and low planting
BALCONY UNIT 3
Garden beds for ground
covers and low planting
51.700
LEVEL 1 LEVEL 1
51.700 51.700
14,550
UNIT 1 UNIT 1 UNIT 1
COURTYARD
3,100
FFL EXISTING
BALCONY Visitors Carparking to Traffic Eng FFL EXISTING
Garden beds for ground
RL 49.940 covers and low planting RL 49.940
1,340
GROUND GROUND
48.600 48.600
500
E NG
1m ABOV
CC2 CC1 HANDRAIL
Garden beds for ground ND ACCESS
L GROU
NATURA
covers and low planting
DRIVEWAY
GATE
Column to Structural Eng
CARSTACKER
4,750
44.889 ZONE
STORAGE UNDER
RAMP
43.350
BASEMENT BASEMENT
43.350 43.350
A2 SECTION
SECTION A2 PROPOSED MULTIPLE RESIDENCE Development Approval Issue rev. A
51 ELANDA STREET, SUNSHINE BEACH 20-11-24 pag. 28
19 SCALE 1:50 1:50
The designs, drawings and specifications within these drawings are copyright and remain the property of ARCHEND. Do not scale this drawing. Any discrepencies to be confirmed with the Designer.
GSPublisherVersion 759.0.71.0
Page 10
APPENDIX Swept Paths and Drawings 51 Elanda Street Traffic Response Letter 21 March 2025
Page 11
Vehicle Turn Path
B
31
B6
14
| 47.157m
ARY 48°24'00"
Y BOUND
PROPERT
CC3
WALL UNDER RAMP
SLAB ABOVE
STORAGE AREA UNDER RAMP
Klaus U10
1,750
UNDER RAMP PARKING AREA
PROPERTY BOUNDARY
UNDER RAMP PARKING AREA
IN GROUND CAR IN GROUND IN GROUND CAR ED A13 A13
LL DASH
STACKER CAR STACKER STACKER RAMP WA 29 29
1:20
5.5x2.85M 5.5x2.85M 5.5x2.85M
5,400
1,900
2,231
1:30
LIFT
2,450
750 1,000
1,100
1&2 3&4 5&6 7 8 9 10
324°49 | 11.778m
300 325
PIT
CARSTACKER SHAFT
ACCESS
BELOW
RL43.350
BIN 1:30
BASEMENT DOOR
STORE
RL43.350 RL43.700 34 Flamingo Crescent ITE CONSULTING
BASEMENT
Thornlands
Queensland
4164
Tel: 0424 110 122 [email protected]
www.iteconsulting.com.au
GF VISITORS CAR PARKING AB NAME: RPEQ: DATE:
LANDING DESIGNED: -
2025/03/05
OVER H EAD
DRAWN: Herman Joubert 25899
STORAGE 25899 2025/03/05
AREA 1.5M SETB
CHECKED: Herman Joubert
ACK COPYRIGHT RESERVED
PROJECT:
PROPERT
Y BOUND
ARY
241°14'00
" | 43.15m 51 Elanda Street
DRAWING TITLE:
AS2890.1:2004 B85
Vehicle Stacker Turn
Path
SCALE E 1:14 RAMP
F
A B C D SCALE: REV:
-
1:86 DATE:
1 0 1 2 3 4 5m 2025/03/05
B DRAWING NUMBER:
31 02
B9
C:\Users\joube\OneDrive - iteconsulting.com.au\6. Projects\0248_51 Elanda Street\RFI\250304 BALEIAS - DWG_z\250304 BALEIAS - DWG\DWG\Xrefed ARCHICAD Views\15 FLOOR PLAN - BASEMENT_3-1. GENERAL ARRANGEMENT - BASEMENT.dwg
Page 12
Vehicle Turn Path
B
31
B6
14
| 47.157m
ARY 48°24'00"
Y BOUND
PROPERT
CC3
WALL UNDER RAMP
SLAB ABOVE
STORAGE AREA UNDER RAMP
Klaus U10
1,750
UNDER RAMP PARKING AREA
PROPERTY BOUNDARY
UNDER RAMP PARKING AREA
IN GROUND CAR IN GROUND IN GROUND CAR ED A13 A13
LL DASH
STACKER CAR STACKER STACKER RAMP WA 29 29
1:20
5.5x2.85M 5.5x2.85M 5.5x2.85M
5,400
1,900
2,231
1:30
LIFT
2,450
750 1,000
1,100
1&2 3&4 5&6 7 8 9 10
324°49 | 11.778m
300 325
PIT
CARSTACKER SHAFT
ACCESS
BELOW
RL43.350
BIN 1:30
BASEMENT DOOR
STORE
RL43.350 RL43.700 34 Flamingo Crescent ITE CONSULTING
BASEMENT
Thornlands
Queensland
4164
Tel: 0424 110 122 [email protected]
www.iteconsulting.com.au
GF VISITORS CAR PARKING AB NAME: RPEQ: DATE:
LANDING DESIGNED: -
2025/03/05
OVER H EAD
DRAWN: Herman Joubert 25899
STORAGE 25899 2025/03/05
AREA 1.5M SETB
CHECKED: Herman Joubert
ACK COPYRIGHT RESERVED
PROJECT:
PROPERT
Y BOUND
ARY
241°14'00
" | 43.15m 51 Elanda Street
DRAWING TITLE:
AS2890.1:2004 B85
Vehicle Stacker Turn
Path
SCALE E 1:14 RAMP
F
A B C D SCALE: REV:
-
1:86 DATE:
1 0 1 2 3 4 5m 2025/03/05
B DRAWING NUMBER:
31 03
B9
C:\Users\joube\OneDrive - iteconsulting.com.au\6. Projects\0248_51 Elanda Street\RFI\250304 BALEIAS - DWG_z\250304 BALEIAS - DWG\DWG\Xrefed ARCHICAD Views\15 FLOOR PLAN - BASEMENT_3-1. GENERAL ARRANGEMENT - BASEMENT.dwg
Page 13
Vehicle Turn Path
B
31
B6
14
| 47.157m
ARY 48°24'00"
Y BOUND
PROPERT
CC3
WALL UNDER RAMP
SLAB ABOVE
STORAGE AREA UNDER RAMP
Klaus U10
1,750
UNDER RAMP PARKING AREA
PROPERTY BOUNDARY
UNDER RAMP PARKING AREA
IN GROUND CAR IN GROUND IN GROUND CAR ED A13 A13
LL DASH
STACKER CAR STACKER STACKER RAMP WA 29 29
1:20
5.5x2.85M 5.5x2.85M 5.5x2.85M
5,400
1,900
2,231
1:30
LIFT
2,450
750 1,000
1,100
1&2 3&4 5&6 7 8 9 10
324°49 | 11.778m
300 325
PIT
CARSTACKER SHAFT
ACCESS
BELOW
RL43.350
BIN 1:30
BASEMENT DOOR
STORE
RL43.350 RL43.700 34 Flamingo Crescent ITE CONSULTING
BASEMENT
Thornlands
Queensland
4164
Tel: 0424 110 122 [email protected]
www.iteconsulting.com.au
GF VISITORS CAR PARKING AB NAME: RPEQ: DATE:
LANDING DESIGNED: -
2025/03/05
OVER H EAD
DRAWN: Herman Joubert 25899
STORAGE 25899 2025/03/05
AREA 1.5M SETB
CHECKED: Herman Joubert
ACK COPYRIGHT RESERVED
PROJECT:
PROPERT
Y BOUND
ARY
241°14'00
" | 43.15m 51 Elanda Street
DRAWING TITLE:
AS2890.1:2004 B85
Vehicle Stacker Turn
Path
SCALE E 1:14 RAMP
F
A B C D SCALE: REV:
-
1:86 DATE:
1 0 1 2 3 4 5m 2025/03/05
B DRAWING NUMBER:
31 04
B9
C:\Users\joube\OneDrive - iteconsulting.com.au\6. Projects\0248_51 Elanda Street\RFI\250304 BALEIAS - DWG_z\250304 BALEIAS - DWG\DWG\Xrefed ARCHICAD Views\15 FLOOR PLAN - BASEMENT_3-1. GENERAL ARRANGEMENT - BASEMENT.dwg
Page 14
B7 31
B8 Vehicle Turn Path
C D E F 14 G #LayID
H
B
31
B6
14
| 47.157m
Y 48°24'00"
Y BOUNDAR
PROPERT
CC3 CC3 CC3
WALL UNDER RAMP
SLAB ABOVE
1:4
STORAGE AREA UNDER RAMP Klaus U10
1,750
UNDER RAMP PARKING AREA UNDER RAMP PARKING AREA
A13 A13 RL45.000
IN GROUND IN GROUND CAR LL DASHED
RAMP WA 29 29
3,
CAR STACKER STACKER
1:20
94
1:6
0
5.5x2.85M 5.5x2.85M
5,400
1,900
2,231
1:30
LIFT BICYCLE
2,450
STORAGE
750 1,000
SHAFT
RL44.342 OPEN
RAMP
1&2 3&4 5&6 7 8 9 10
300 325
BELOW LIFT ACCESS AREA
1:8
6
19
4,
RL43.350
34 Flamingo Crescent ITE CONSULTING
1:30 Thornlands
BASEMENT DOOR
Queensland
4164
RL43.350 RL43.700
BASEMENT 1:8 Tel: 0424 110 122 [email protected]
www.iteconsulting.com.au
OVERHEAD PLANTER
NAME: RPEQ: DATE:
CC1 DESIGNED: -
DRAWN: Herman Joubert 25899 2025/03/05
CHECKED: Herman Joubert 25899 2025/03/05
LANDING
RL43.849 HANDRAIL COPYRIGHT RESERVED
OVERHEAD
STORAGE PROJECT:
AREA 1.5M SETB
ACK
51 Elanda Street
UP
RL45.758
PROPERT GATE
Y BOUND
ARY
241°14'00
1
2
3
" | 43.15m
4
5
6
7
8
10
9
11
12
DRAWING TITLE:
AS2890.1:2004 B85
GATE
Vehicle Stacker Turn
Path
BASEMENT SCALE: REV:
ACCESS FROM -
1:86
6
DATE:
5
PEDESTRIAN
4
3
E 1:14 RAMP
F
2
G H 2025/03/05
1
C D FOOTPATH DRAWING NUMBER:
LANDING 05
RL45.758
C:\Users\joube\OneDrive - iteconsulting.com.au\6. Projects\0248_51 Elanda Street\RFI\250304 BALEIAS - DWG_z\250304 BALEIAS - DWG\DWG\Xrefed ARCHICAD Views\15 FLOOR PLAN - BASEMENT_3-1. GENERAL ARRANGEMENT - BASEMENT.dwg
Page 15
Vehicle Details
1:8 1:40 1:20 1:20
1:8
1:4
34 Flamingo Crescent ITE CONSULTING
Thornlands
Queensland
4164
Tel: 0424 110 122 [email protected]
www.iteconsulting.com.au
NAME: RPEQ: DATE:
DESIGNED: -
DRAWN: Herman Joubert 25899 2025/03/05
CHECKED: Herman Joubert 25899 2025/03/05
1:4 COPYRIGHT RESERVED
2,242
PROJECT:
2,216
51 Elanda Street
1:4
DRAWING TITLE:
1:6 AS2890.1:2004 B99
Vertical and Ground
Clearance
SCALE: REV:
-
1:86 DATE:
2025/03/05
DRAWING NUMBER:
07
C:\Users\joube\OneDrive - iteconsulting.com.au\6. Projects\0248_51 Elanda Street\RFI\250304 BALEIAS - DWG_z\250304 BALEIAS - DWG\DWG\Xrefed ARCHICAD Views\28 SECTION A7_A7SECTION.dwg
The text continues on page 16.
Used in these records
RFI - Traffic Response Letter.pdfRelated documentApplication case desk ↗
About this file
- File size
- 14.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.